• Title/Summary/Keyword: Wall conditioning

Search Result 402, Processing Time 0.018 seconds

Simulation of the Thermal Performance on an Ondol House with Hot Water Heating in Consideration of Radiation Heat Transfer (복사열전달을 고려한 모형 온수온돌 주택 열성능 시뮬레이션)

  • Choi, Y.D.;Yoon, J.H.;Hong, J.K.;Lee, N.H.;Kang, D.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.295-305
    • /
    • 1993
  • Thermal performance of test cell of model hot water Ondol house was simulated by equivalence heat resistence and heat capacity method. In this method wall was replaced by two equivalence and one heat capacity. This method enables to simulate the variation of temperature of each element of model house. The effect of pipe diameter, pitch of pipe and with or without consideration of inter-radiation between wall surfaces on the energy consumption rate were investgated. Results show that radiations between the ground surface of room and wall surfaces contribute to the heating of room air by reducing the convection heat loss through the wall surfaces.

  • PDF

An Experimental Study on Melting Process of Ice in a Rectangular Cavity with Different Wall Temperature (양벽온이 다른 장방형용기 내에서 얼음의 융해과정에 관한 실험적 연구)

  • Lim, W.T.;Kim, B.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.547-555
    • /
    • 1995
  • Melting process of ice in a rectangular cavity with different temperature walls has been studied experimentally. Front shape of ice and melting rate were affected by initial temperature of ice and variation of temperature distribution and density gradient. When the hot wall temperature was below $8^{\circ}C$, the melting rates were higher at the bottom than those of at the top due to the density inversion, but with increasing the hot wall temperature the melting rates at the top were affected by hot wall and were higher than those of at the bottom. When the initial temperature of ice was low, melting rates were low, but with increasing the time melting rates were almost the same with those of each initial temperature of ice.

  • PDF

An Experimental Study on the Natural Convection from the Isothermal Square Beam with an Adiabatic Wall (단열벽(斷熱壁)에 부착(附着)된 등온사각(等溫四角)비임에서의 자연대류(自然對流) 열전달(熱傳達))

  • Lee, C.J.;Park, J.L.;Kwon, S.S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.1
    • /
    • pp.65-73
    • /
    • 1988
  • Steady laminar natural convection heat transfer from an isothermal square beam with adiabatic wall has been studied for various inclination angles of the wall and Rayleigh numbers by using Mach-Zehnder Interferometer in air. The different temperature and fluid fields were obtained as the inclination angle changes showing the effects of the ascending heated fluid and the adiabatic wall. The maximum total mean Nusselt number was found at ${\theta}=45^{\circ}$.

  • PDF

Analysis on Surface Temperature Control of an Insulated Vertical Wall Under Thermal Radiation Environment (단열재가 부착된 수직벽 표면의 온도제어 해석)

  • Kang, Byung-Ha;Pi, Chang-Hun;Kim, Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.323-329
    • /
    • 2012
  • In this study, a rational procedures for estimation of insulation thickness of a vertical wall for condensation control or personnel protection has been investigated. Design parameters are height of the wall, thermal conductivity, emissivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation for the purpose of surface temperature control, especially in natural convection situation. radiation heat transfer coefficients for some new insulation material surface, such as elastomers, estimated to be more than 90% of the total surface heat transfer coefficient.

Analysis of the Combined Surface Radiation-Natural Convection in a Rectagular Enclosure with a Selectively Transparent Wall (선택적 투과성면을 가진 직사각형 밀폐공간에서의 표면복사 및 자연대류해석)

  • Park D. S.;Lee T. S.;Lee J. S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.2
    • /
    • pp.194-203
    • /
    • 1987
  • A numerical study has been conducted on the combined radiation-natural convection heat transfer characteristics in a square cavity with a selectively transparent wall. The fluid in the cavity is assumed to be transparent to the thermal radiation. The effect of the wall emissivity is mainly considered in view of the temperature and flow fields. The comparison of the radiative heat flux and conductive heat flux variations along the isothermal wall is presented as well. The results show that the Nusselt number distribution is fairly uniform due to the com-pensative interaction of the radiation and convection heat transfer.

  • PDF

A Performance Equation of Bath Tubs (욕조의 보온성능연구)

  • Lee, Byung-Ho;Suh, Jung-Il
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 1981
  • In this paper, a new performance equation of bath tubs has been derived, which is very characteristically illuminating and in good agreement with experiments : $$T=T_{\infty}+(T_0-T_{\infty})e-\frac{k(A'_f+A_0)}{Mc_{P{\Delta}x}t$$, where $T_{\infty}$ is the temperature of the bathroom, $T_0$ that of the bathwater at t=0, k the overall heat conductivity of the tub- wall, $A'_f$ the equivalent surface area to the wall, $A_0$ the submerged area of the tub-wall, M mass of the bath-water, $C_p$ the specific heat of the bathwater and ${\Delta}x$ the thickness of the tub-wall. Here the equivalent-free surface area is written as $$A'_f=mA_f,\;m=const.(1-{\phi})^{0.88}$$ : where m is a numerical factor which is determined by a simple experiment and some calculation, {\phi}$ the relative humidity and $A_f$ the real free-surface area. From this study, it has been clarified that cooling of bath-water is mainly due to mass-transfer through evaporation from the free surface and conductive heat loss through the tub-wall is minor, which rather gaily mock at common sense. The effect of keeping bathwater warn by increase of the tub-wall thickness is also analyzed by a new idea of the thickness gain factor.

  • PDF

Identification between Local Wall Thinning and Turbulent Velocity Components by Flow Acceleration Corrosion inside Tee of Pipe System (배관계 티에서 유동가속부식으로 인한 난류속도성분과 국부감육의 관계 규명)

  • Kim, Kyung-Hoon;Lee, Sang-Kyu;Cho, Yun-Su;Hwang, Kyung-Mo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.483-491
    • /
    • 2011
  • When pipe components made of carbon steel in nuclear, fossil, and industry are exposed to flowing fluid, wall thinning caused by FAC(flow accelerated corrosion) can be generated and eventually ruptured at the portion of pressure boundary. A study to identify the locations generating local wall thinning and to disclose turbulence coefficient related to the local wall thinning was performed. Experiment and numerical analyses for tee of down scaled piping components were performed and the results were compared. In particular, flow visualization experiment which was used alkali metallic salt was performed to find actual location of local wall thinning inside tee components. To disclose the relationship between turbulence coefficients and local wall thinning, numerical analyses were performed for tee components. The turbulence coefficients based on the numerical analyses were compared with the local wall thinning based on the measured data. From the comparison of the results, the vertical flow velocity component(Vr) flowing to the wall after separating in the wall due to the geometrical configuration and colliding with the wall directly at an angle of some degree was analogous to the configuration of local wall thinning.

Comparison of the PMV and $CO_2$ Concentration, Energy Consumption Characteristics of Central Air-Conditioning System and System Air-Conditioner with Ventilation System for Large Space (중형공간에서 중앙공조방식과 시스템에어컨 방식에 따른 PMV와 $CO_2$농도, 에너지소비량 비교)

  • Sung, Sang-Chul;Noh, Kwang-Chul;Chin, Sim-Won;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.298-303
    • /
    • 2008
  • PMV, $CO_2$ and the energy consumption performance were numerically investigated in a large space with air-conditioning systems of four type. The numerical results showed that thermal comforts in the occupied zone are nearly similar in three systems except 3-way wall type system air-conditioner with ventilation system installed 2.2m height from the bottom. In case of 3-way wall type system air-conditioner the energy consumption for cooling loads was reduced about 25.5% compared to other air-conditioning systems. From the viewpoint of IAQ, it was turned out that system air-conditioner with ventilation system became worse about 20% compared to central air-conditioning systems for cooling load. The PMV, $CO_2$ concentration and energy consumption of all systems for heating loads were similar in a large space considered.

  • PDF

Characteristics of Particle Deposition onto the Cleanroom Wall Panel with Electrostatic Voltages (정전압에 따른 클린룸 벽체에서의 입자침착 특성)

  • Noh, Kwang-Chul;Son, Young-Tae;Kim, Jong-Jun;Oh, Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1033-1038
    • /
    • 2006
  • We carried out the experiments on particle deposition onto the cleanroom wall panels. And then we investigated the particle deposition characteristic coefficients for electrostatic voltages and particle size. It was found that there is little difference in characteristics of the particle deposition between the steel panel and the anti-static coating panel. In case of that the particle size is under $1.0{\mu}m$, the particle deposition characteristic coefficient becomes larger as the electrostatic voltage induced to the cleanroom wall panel is increasing. Where in case of that the particle size is over $3.0{\mu}m$, the particle deposition characteristic coefficients do not show any differences with the electrostatic voltages. It is due to that the electrostatic force is the major particle transport mechanism for submicron particles, while the gravitational settling is the major particle transport mechanism for overmicron particles when the electro-static voltages are induced to the cleanroom wall panel.

A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds (실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석)

  • Hyun, In-Tak;Lee, Jae-Ho;Yoon, Yeo-Beom;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.