• Title/Summary/Keyword: Wall Removal

Search Result 308, Processing Time 0.034 seconds

Performance Evaluation of Wall Blower Nozzle using Erosion Analysis (침식 해석을 이용한 월 블로워 노즐의 성능 예측)

  • Paek, Jae Ho;Jang, llkwang;Jang, Yong Hoon
    • Tribology and Lubricants
    • /
    • v.34 no.5
    • /
    • pp.175-182
    • /
    • 2018
  • Accumulation of coal ash at the boiler wall reduces combustion and fuel efficiency. The design of a wall blower is important to effectively remove coal ash. We present numerical results for the removal of coal ash from boiler walls of domestic coal-fired power plants, associated with the computational fluid dynamics for the flow from spray nozzle to boiler wall. The numerical model simulates an erosion process in which the multiphase fluid comprising saturated vapor and fluid water is sprayed from the nozzle, and the water particles impact the boiler wall. We adopt the Finnie erosion model for water particles. We obtain the erosion rate density as a function of nozzle angle and its injection angle. As excessive coal ash removal usually induces damage to the boiler wall, the removal operation typically focuses on a large area with uniform depth rather than the maximum removal of coal ash at a specific location. In order to estimate the removal performance of the wall blower nozzle considering several functionality and reliability factors, we evaluate the optimal injection and nozzle angles with respect to the biggest cumulative and highest erosion rates, as well as the widest range and lowest standard deviation of the erosion rate distribution.

A Study on the Physical Environmental Alternations and the Using Characteristics of the Street Place by the Wall Removal Project Types (아파트 담장허물기 유형별 가로공간의 물리적 환경변화 및 이용특성 연구)

  • Kim, Myo-Jung;Jeong, Ji-Seok
    • Journal of the Korean housing association
    • /
    • v.24 no.2
    • /
    • pp.25-33
    • /
    • 2013
  • The purpose of this study was to compare the differences between two types of wall removal projects. One was the case that removed one side wall of the apartment in Daegu, another was the instance that eliminated the walls between two apartments in Gimcheon. For this study, the observation method was performed to know the using pattern on the street space, and survey including resident's opinion and satisfaction about result of the project was conducted to gather data. The total number of objects to analysis was 157. The conclusion of this study is as follows. First, when the space was secure from danger of cars, people could access easily. And when it had interesting elements, the street space after wall removal was used by residents. Second, the effective method to connect places was to make intermediate space after wall removal project. In this sense, the way can help to improve the level of quality the daily life of residents. Finally, in the apartment-oriented wall removal project, it could supplement the flaw of the detached house-oriented project and effective potentiality for vitalization of community.

토양가스추출법의 제거효율 평가

  • 이창수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.285-288
    • /
    • 2003
  • When the soil vapor extraction as a remediation method of contaminated soil and groundwater has been used, the effects of curtain wall, mode of pump operation were examined by numerical simulation. Consequently, it was found that the removal rate was enhanced in case that the curtain wall was established around the extraction well with the extraction pumps operated alternatively. It was because that the removal of high density gas around the extraction well was possible.

  • PDF

Effect of Material Removal per Tooth on the Axial Shape of Prismatically Milled Parts (공구날당 소재제거량이 각주형상 밀링가공물의 축방향 형상에 미치는 영향)

  • Kim Kwang Hee
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.17-22
    • /
    • 2004
  • A study for investigating the effects of the cutting conditions (radial depth of cut feed per tooth) and the number of tooth on the side wall of prismatically milled workpiece is described. This study is available not only for understanding the geometrical characteristics of the end milled side wall but also for finding the optimal cutting conditions. In this work, the side wall geometry was characterized by the straightness and the location of maximum peak point. Through this study, it was revealed that the geometrical characteristics of the end milled side wall are strongly related to the material removal per tooth and the number of tooth.

A Study on the Removal Efficiency of the Soil Vapor Extraction by Numerical Simulation (수치모형에 의한 토양증기추출법의 제거효율에 관한 연구 - 차단벽, 추출유량, 펌프가동방법의 영향 -)

  • Lee, Chang-Su
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.2
    • /
    • pp.121-129
    • /
    • 1999
  • When the soil vapor extraction as a remediation method of contaminated soil and groundwater has been used, the effects of curtain wall, mode of pump operation and magnitude of extraction flowrate were examined by numerical simulation. Consequently, it was found that the removal rate was enhanced in case that the curtain wall was established around the extraction well with the extraction pumps operated alternatively. It was because that the removal of high density gas around the extraction well was possible. It was found that the removal efficiency of TCE gas did not depend on the extraction flowrate. However, the removal rate of TCE gas at varying extraction flowrate was not enhanced flowrate increase.

  • PDF

A Study of Thermal and Chemical Quenching of Premixed Flame by Flame-Surface Interaction (화염-표면 상호작용에 의한 예혼합 화염의 열소염 및 화학소염에 관한 연구)

  • Kim, Kyu-Tae;Lee, Dae-Hoon;Kwon, Se-Jin
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • Incomplete combustion due to quenching in a narrow confinement has been a major problem for realization of a reliable micro combustion device. In most micro combustors, effects of flows are absent in the quenching because the flow is laminar and no severe stretch is present. In such circumstance, quenching is caused either by heat loss or by removal of active radicals to the wall surface of the confinement. An experimental investigation was carried out to investigate the relative significance of these two causes of quenching of a premixed flame. A premixed jet burner with a rectangular cross section at the exit was built. At the burner exit, the flame stands between two walls with adjustable distance. The gap between the two walls at which quenching occurs was measured at different wall surface conditions. The results were analyzed to estimate the relative significance of heat loss to the wall and the removal of radicals at the surface. The measurements indicated that the quenching distance was independent of the wall surface characteristics such as oxygen vacancy, grain boundary, or impurities at low temperature. At high temperature, however, the surface characteristics strongly affect the quenching distance, implying that radical removal at the wall plays a significant role in the quenching process.

  • PDF

SS Removal-rate Efficiency of Storm-water Detention Storage Tank Depending upon Length, Inside Training Wall and Gravel Filling (우수저류조의 형상과 도류벽 및 자갈채움에 따른 SS 제거효율)

  • Lee, Jong Tae;Seo, Hong Joon;Seo, Kyung A
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.655-667
    • /
    • 2009
  • An experimental study is performed on reducing the pollutants supplied by storm water through enhancing efficiency of SS from the detention storage tank where CSOs are kept temporarily before discharge to the receiving water system. SS removal efficiency is investigated in accordance with various conditions of the detention pond-such as its length, the existence of training wall, and the use of gravel filling. The removal efficiency is strongly affected by the detention pond's length until the critical falling distance of the suspended solids is reached. For cases where the tank has a length longer than this critical condition, the removal rate shows less sensitivity. To enhance the SS removal efficiency of tanks of shorter than the critical length, we studied alternative types of tank in which inside training walls are installed. The results showed improvement of 14 to 37% in removal efficiency in 2hours detention(2 training walls). The important factor in achieving a high SS removal rate is ensuring the critical length of the detention pond, but for the cases where the basin length cannot be guaranteed, baffles or a gravel filling scheme may be introduced to attain considerable efficiency. The results of studying and comparing different storage tank conditions show that, in terms of elimination efficiency, a storage tank with gravel filling and training walls > a storage tank with gravel filling > a storage tank with training walls > an empty tank. The experimental results should contribute to development of related further research, by empirically verifying the already assumed importance of critical falling distance, training walls, and gravel filling schemes.

A Study on the optimal length of air cavity for Solar heat removal with Air-Vent System (일사열 배제를 위한 통기벽체 적정 길이에 대한 검토)

  • Kim, Sang-Jin;Kum, Jong-Soo;Choi, Kwang-Hwan;Shin, Byong-Hwan;Chung, Yong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.33-38
    • /
    • 2004
  • Outside wall systems we lost much energy from the dew of thermal bridge and unsuitable adiabatic construction. The air vent wall system can make reduce cooling loads from the outside wall in summer. The basic concept is connected with buoyant force by the difference of density. An external surface of a wall absorbs solar radiation, and transfers it to the air in the cavity. The warmed air gets buoyant force. So the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable. The purpose of this study is finding optimal length of air cavity by numerical analyses.

Mutanase Induction in Trichoderma harzianum by Cell Wall of Laetiporus sulphureus and its Application for Mutan Removal from Oral Biofilms

  • Wiater, Adrian;Szczodrak, Janusz;Pleszczynska, Malgorzata
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.7
    • /
    • pp.1335-1341
    • /
    • 2008
  • The cell wall material from fruiting bodies of Laetporus sulphureus has been suggested as a new alternative to mutan for the mutanase induction in Trichoderma harzianum. Structural analyses revealed that the cell wall fraction from this polypore fungus contained 56.3% of (1$\rightarrow$3)-linked $\alpha$-glucans. When the strain T. harzianum F-340 was grown on a cell wall preparation from L. sulphureus, the maximal enzyme productivity obtained after 3 days of cultivation was 0.71 U/ml. This yield was about 1.8-fold higher than that achieved on mutan, known so far as the best, but expensive and inaccessible, inducer of mutanase production. Cell-wall-induced mutanase showed a high hydrolytic potential in reaction with a dextranase-pretreated mutan, where maximal degrees of saccharification and solubilization of this biopolymer (80% and 100%, respectively) were reached in 3 h at 45$^{\circ}C$. The mutanase preparation was also effective in degradation of streptococcal mutan and its removal from oral biofilms, especially in a mixture with dextranase.

A COMPARATIVE STUDY OF THE EFFECT K - FILE AND ULTRASONIC INSTRUMENT IN CLEANING AND SHAPING ROOT CANAL (K-File과 초음파기구의 근관확대 및 세척효과에 대한 비교연구)

  • Kim, Sang-Seop;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.413-420
    • /
    • 1992
  • The purpose of this study was to compare the effectiveness of hand instrumentation with K - file and ultrasonic instrumentation and irrigation system in removing pulpal debris and canal wall planing. 20 mandibular molar teeth were instrumented to size 30 K - file and 20 teeth were instrumented with ultrasonic Suprasson. And Normal Saline and 2.5% NaOCl were used as irrigation solution. All specimens were viewed at the coronal, middle, and apical third of the root canals for the evaluation of the cleaning effect under the multiview microscope. The result were as follows : 1. All of the technique and irrigation solution was effecient in the debris removal and canal wall planing at the cervical and middle thirds of the root canal. 2. All of the techniques and irrigation solutions was less efficient in the debris removal and canal planing at the apical third of the root canal. 3. The debris removal and canal wall planing was depended more on the anatomical variations of the root canal than on the techniques and irrigation solutions.

  • PDF