• Title/Summary/Keyword: Wall Pad

Search Result 42, Processing Time 0.036 seconds

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.

A Study on Performance Evaluation and Security Measures of U-IT Electrical Safety Integrated Management System's Module (U-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dea-Woo;Choi, Choung-Moon;Kim, Eung-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.307-310
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. U-City in order to prevent the disaster of U-IT Power Equipment Performance Module and the security for the safety of the U-City is necessary. In this paper, the power unit of U-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation and security measures will be studied. U-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as U-IT integrated management system for electrical safety and strengthen the security, safety and security with a U-City will contribute to the construction and operation.

  • PDF

Consideration of thickness change during progressive drawing process of automotive coupler parts(AL5052-H32) (자동차 커플러 부품(Al5052-H32)의 프로그래시브 드로잉 공정 시 두께 변화 고찰)

  • Park, Sang-Byung;Yun, Jae-Woong
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.37-43
    • /
    • 2020
  • Progressive drawing processing is one of the manufacturing processes used to mass-produce a variety of products on the industrial site. In this study, the goal is to achieve a uniform product thickness of at least 1.3mm by reducing the wall thickness of the coupler parts used in automotive air conditioning systems to within 15% using A5052-H32 materials. The progressive die was designed using Blank's law of volume invariance. Due to the characteristics of the drawing process, the material thickness in the punch R part decreases and the thickness in the die R part increases. When designing the progressive die of the coupler part, an ironing method, a push back method, and a stand-alone die pad method were applied to each process to design a mold in consideration of the drawing rate and to artificially adjust the thickness change. The suitability of the method used in die design was investigated by measuring the thickness change of forming parts for each process. In the final part, it was confirmed that the thickness measurement values of the five regions of a radial line were implemented as 1.34-1.36 mm.

Wall-Suction Assisted Vacuum Sealing for Treatment of Infected Diabetic Foot Ulcer (벽매립형 중앙 흡인장치를 이용한 감염성 당뇨병성 족부 궤양의 밀봉 치료)

  • Bae, Su-Young;Lee, Chang-Wook;Seo, In-Seock
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.26-30
    • /
    • 2004
  • Purpose: The infected diabetic foot patients were reviewed to analyze the result of new dressing methods using a wall-suction instruments. Materials and Methods: Eighteen patients treated with wall-suction assisted vacuum dressing were included. After debridement under local anesthesia, a sponge pad, a drain, and a surgical drape were used to seal the wound. Negative pressure applied by the wall-suction at around 200 mmHg and dressing were repeated in every two to three days. The results of repeated wound cultures, growth of granulation tissues, and CRP level were closely observed on the regular basis. Results: Rapid growth of granulation tissues was noticed around the wound in 16 cases. No organism was obtained in an average 5 days and wound coverage was possible in an average 18 days. The CRP level returned to normal in an average 4 weeks. Two patients with end stage renal disease, who were regularly hemodialised, underwent major amputation. Conclusion: New dressing method has the following advantages: a rapid wound improvement in the patients with infected diabetic foot, less expensive, less painful, impediment of bacterial contamination in the hospital room. However, further study will be needed for the end stage renal disease patients.

  • PDF

Lateral Oropharyngeal Wall Coverage with Buccinator Myomucosal and Buccal Fat Pad Flaps

  • Jung, Bok Ki;Song, Seung Yong;Kim, Se-Heon;Kim, Young Seok;Lee, Won Jai;Hong, Jong Won;Roh, Tai Suk;Lew, Dae Hyun
    • Archives of Plastic Surgery
    • /
    • v.42 no.4
    • /
    • pp.453-460
    • /
    • 2015
  • Background Reconstruction of oropharyngeal defects after resection of oropharyngeal cancer is a significant challenge. The purpose of this study is to introduce reconstruction using a combination of a buccinator myomucosal flap and a buccal fat pad flap after cancer excision and to discuss the associated anatomy, surgical procedure, and clinical applications. Methods In our study, a combination of a buccinator myomucosal flap with a buccal fat pad flap was utilized for reconstruction after resection of oropharyngeal cancer, performed between 2013 and 2015. After oropharyngectomy, the defect with exposed vital structures was noted. A buccinator myomucosal flap was designed and elevated after an assessment of the flap pedicle. Without requiring an additional procedure, a buccal fat pad flap was easily harvested in the same field and gently pulled to obtain sufficient volume. The flaps were rotated and covered the defect. In addition, using cadaver dissections, we investigated the feasibility of transposing the flaps into the lateral oropharyngeal defect. Results The reconstruction was performed in patients with squamous cell carcinoma. The largest tumor size was $5cm{\times}2cm(length{\times}width)$. All donor sites were closed primarily. The flaps were completely epithelialized after four weeks, and the patients were followed up for at least six months. There were no flap failures or postoperative wound complications. All patients were without dietary restrictions, and no patient had problems related to mouth opening, swallowing, or speech. Conclusions A buccinator myomucosal flap with a buccal fat pad flap is a reliable and valuable option in the reconstruction of oropharyngeal defects after cancer resection for maintaining functionality.

Development of a wall climbing robot with vacuum caterpillar wheel system (흡착 캐터필러 시스템을 이용한 수직평면 등반로봇 기구부의 개발)

  • Kim Hwang;Kim Dong-Mok;Yang Ho-Joon;Lee Kyou-Hee;Seo Kun-Chan;Chang Do-Young;Kim Jong-Won
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.55-56
    • /
    • 2006
  • This paper describes a new concept of the robot that can climb on the vertical plane. The engineering design problem of the main structure is presented and the experimental results regarding a new mechanism of climbing on the vertical wall are discussed. The locomotive motion of the robot is realized by using a series chain of two caterpillar wheels on which 24-suction pads are installed. White each caterpillar wheel rotates on the vertical plane surface, the vacuum pads are activated in sequence based on the sequential opening by specially designed mechanical valves. The detail design feature of the valve is also described in this paper. The overall size of the robot is around 460 mm in width and length, respectively, and 200 mm in height. Its mass is slightly over 14 kg. The main mechanical structure of the robot consists of driving motors, vacuum caterpillar system, steering part, vacuum pump and battery. The performance of the robot is verified on the vertical wall.

  • PDF

Familial Surpravalvular Aorctic Stenosis in Two Silings (남매에서 발생한 가족성 판상부 대동맥협착증)

  • 강재걸
    • Journal of Chest Surgery
    • /
    • v.21 no.6
    • /
    • pp.1145-1151
    • /
    • 1988
  • Supraventricular tachyarrhythmias are readily characterized and understood, but the surgical procedures for their correction are complex and not easily mastered. Conversely, ventricular tachyarrhythmias are frequently difficult to characterize and localize electrophysiologically and their basic mechanisms are poorly understood. The role of the surgeon in the treatment of cardiac arrhythmia has changed dramatically during the past decade. This report is a case of 26 years old male with supraventricular tachyarrhythmia. The result of endocardial electrophysiologic study demonstrated accessory pathway connecting left atrium to left ventricle which located at left atrial free wall about 4 cm apart from the coronary sinus orifice. The accessory bundle interruption has been successfully accomplished utilizing the internal open heart technique. The operation consisted of dissection of the atrioventricular fat pad and division of all the superficial fibers going from the ventricle to the annulus. Following this, cryoablation made with cryoprobe at - 60` for 90 seconds. The accessory pathway was successfully ablated without specific problems.

  • PDF

Variation of the Switching Field of Composite Nanowires with Different Widths

  • Kim, Seung-Ho;Lee, Han-Seok;Lee, Seung-Hyun;Lee, Woo-Young;Lee, J.
    • Journal of Magnetics
    • /
    • v.13 no.4
    • /
    • pp.167-169
    • /
    • 2008
  • The switching field of a 300 nm wide nanowire has been controlled by attaching a wide wire to it. The width of the wide wires varies from 700 nm to 2000 nm. While the connection of the two wires does not affect the switching field of the wide wires, it strongly affects the 300 nm-wire, resulting in a decrease of the switching field of the isolated wire from 175 Oe to 54 Oe when the 2000 nm-wire is connected to it. This result clearly shows that the switching field of the nanowire can be engineered by attaching a nucleation pad that has a different magnetic anisotropy.

A Study on Authentication Design and Method of Electrical IT Equipment (전기IT기기의 인증설계와 인증방법 연구)

  • Park, Dea-Woo;Choi, Choung-Moon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.155-158
    • /
    • 2011
  • U-city구축에서 전기의 안전한 공급과 전기로 인한 화재 등 재난에 대한 통제가 가능해야 한다. U-city에 구축되어야 할 Smart Grid 네트워크와 Smart Grid 인프라 구축을 위해서 사용되는 전기IT기기에 대한 인증을 위한 인증설계와 인증방법에 대한 연구가 필요하다. 본 논문에서는 개발이 진행 중인 전기IT기기의 인증을 위하여 국내 국제표준화 기준을 연구한 후 국내에서 인증 받을 수 있는 인증설계를 연구한다. 인증설계는 Home Network Wall-Pad, 비접촉식 아크 검출기, 아크 안전진단, 아울렛, 저전압 배전반(MPNP) 블랙박스, 차단기이다. 그리고 인증기관에서 인증적용과 인증내용 및 평가기준과 전기IT기기의 인증심의 기관에서 기준 값 등에 관한 연구를 한다. 본 연구는 Smart Grid 네트워크와 인프라 구축을 위한 실무적인 연구 자료로 활용될 것이다.

  • PDF

Evaluation of Skin Microcirculation by Laser Doppler Flowmeter in Healthy Beagle Dogs

  • Kim, Juntaek;Bae, Seulgi;Lee, Keunwoo;OH, Taeho
    • Journal of Veterinary Clinics
    • /
    • v.34 no.4
    • /
    • pp.249-254
    • /
    • 2017
  • The cutaneous microcirculation plays a role in various physiological processes and pathological conditions. Two non-invasive methods were used in this study to obtain reference values for cutaneous microcirculation in intact male beagles. Twenty intact male beagles were used. The experimental environments were standardized. Laser Doppler flowmetry was used to measure cutaneous blood flow, and an infrared thermometer was used to measure cutaneous temperature. The blood flow and temperature were measured from the right side of the subjects at 20 cutaneous sites. Based on the laser Doppler flowmetry, the region with the highest blood flow was the periocular region that with the lowest was the forelimb foot pad. In addition, the standard deviation of the chest wall was the highest while that of the periocular region was the lowest. For skin temperature, the inguinal region had the highest mean skin temperature and the forelimb foot pad had the lowest. The correlation coefficient between the two methods was 0.72. Similar to a previous study, the values derived from repeated measurements at the 20 regions are reproducible and can contribute to research. Compared to the results of a previous study, the temperatures of the two smallest skin regions were the same; however, no specific trend was observed. The correlation coefficient between the two methods was significantly comparable, and this good correlation can reduce their limitations and variables complementarily. In addition to possible use in human studies, accumulated resources on measurements of skin blood flow in the future will potentiate its use in the veterinary medicine field.