• Title/Summary/Keyword: Wall Loss

Search Result 785, Processing Time 0.026 seconds

A Study on the Role of Wall Posts in Pit-Houses - In Bronze Age settlement sites in the Kyung-nam Province - (움집 벽주(壁柱)의 흙막이벽 기능에 관한 연구 - 경남지역 청동기 주거지를 중심으로 -)

  • Park, Won-Ho;Seo, Chi-Sang
    • Journal of architectural history
    • /
    • v.17 no.5
    • /
    • pp.7-22
    • /
    • 2008
  • The purpose of this study is to examine the function of wall posts in pit-houses in the Bronze Age, in the Kyung-nam Province. Wall posts were found as post-holes, created after wooden posts had decayed. In this research, the role of wall posts is newly defined from the perspective of a construction engineering. While existing studies in archaeology regard wall posts as sub-posts that support the roof of a pit-house, this study views wall posts as piles installed to support the soil wall, not as sub-posts. Based on the existing reports on excavation in prehistoric settlement sites by archaeologists, the study examines the remnants of the wall posts and remains after a fire. The main findings of this study are threefold. First, the wall posts were installed not as posts but as piles, cut sharply and hammered along the building lines of a pit-house. Second, wall piles were used to support the walls during earthwork, such as excavating and banking for low ground, mostly because a large amount of soil is often lost during the process. Third, wall piles were used as post piles of retaining walls that enabled the installation of transverse wall panels, which were used to prevent the soil loss.

  • PDF

Experimental Study on Wall Sound Transmission Loss at Construction Equipment Machinery Room (건축설비 기계실의 벽체 투과손실에 관한 실험적 연구)

  • Kook, Joung-Hun;Jung, Chul-Woon;Yun, Jae-Hyun;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.701-705
    • /
    • 2007
  • The equipment noise of machine room that generates at the building where human-being is living, is becoming to an object of strong civil appeal, and because it influences to the residential space through the floor or wall, its damage is very serious level. Accordingly, while an efficient forming of the sound insulating measures is earnest, as most of the transmission loss data was the material measured in laboratory, in case when it was applied to the job site, due to the precision difference of constructing work and the influence of detoured transmitting sound, the case of disaccord is the most. Therefore, this thesis has intended to present a fundamental data for an efficient establishment of sound insulation measure, by means of comparison analysis with the existing transmission loss data, after measurement of the transmission loss on the object of various walls, at the construction equipment machinery room.

  • PDF

A Comparative strudy on the Insulation Performance of the Super Window by Actual Survey and Simulation (초단열 슈퍼윈도우의 단열성능 실측과 시뮬레이션 비교 분석)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Jang, Cheol-Yong;Hong, Won-Hwa
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.231-235
    • /
    • 2009
  • According to flow of energy, the loss occurs through walls, roofs, windows and so on. Among these case, most of the loss that is about 45% occurs through windows. windows's U-value is six times higher than wall's one according to Building code, so the loss through windows accounts for very much rates. Currently, Exterior wall's U-value about building envelope is 0.35~0.58W/ mK, but windows's one is 3.3W/ mK. It means that the loss through windows occupy very much amounts relatively. Therefore, the solution is required to reduce energy loss and increasing displeasure caused by excessive influx of solar energy through windows, to solve the problems Like decoloration on indoor furniture an clothes by harmful ultraviolet rays, air conditioning and increased cost. Therefore, on this paper, Thermal Performance was evaluated through actual test about high insulation Super Window which can improve thermal performance and the Simulation result was compared with actual resul by using Simulation program WINDOW and THERM.

  • PDF

Flame Propagation in a Micro Vessel under Excessive Heat Loss (과도한 열손실을 수반하는 초소형 정적연소실 내 화염전파)

  • Na, Han-Bee;Choi, Kwon-Hyoung;Kwon, Se-Jin
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.95-98
    • /
    • 2002
  • A numerical investigation on the flame propagation and extinction in a micro combustor is described. Previous measurements of $H_2-air$ flame propagation in a submilimeter scale combustor exhibited significance of wall effects on burning velocity and extinction. The heat transfer to wall becomes important not only in the cooling of burnt gases but also during the flame ropagation, which has be by and large ignored in macro scale combustor calculations. In order to take the heat loss into account the combustion calculation, we developed a numerical code with a heat transfer model that was determined empirically from measured data. PISO algorithm was used for differencing of conservation equations. $H_2-air$ reaction was modeled with 10 species - 16 steps. Comparison with measured data showed good agreement in flame propagation speed. Also the pressure decrease after flame extinction was accurately predicted by the model. A further study is desirable for a better quenching model that can predict the quenching location.

  • PDF

Some Insights into the Basic QA/QC for the Greenhouse Gas Analysis: Methane and Carbon Dioxide (온실가스 기기분석의 정도관리를 위한 고려사항 연구 - CH4과 CO2를 중심으로 -)

  • Jeong, Jae-Hak;Lim, Ho-Soo;Kim, Ki-Hyun;Bae, Wi-Sup;Jeon, Eui-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.712-718
    • /
    • 2006
  • In order to investigate the analytical uncertainties associated with sampling and analysis of major greenhouse gaseous pollutants(carbon dioxide and methane), we attempted to quantify their adsorptive loss due to the contact with the container wall(such as Tedlar bag and vial). Using the GC/FID method, some basic experimental parameters(such as reproducibility and method detection limit) have been evaluated as part of the essential QA/QC The reproducibilities of carbon dioxide and methane were estimated as 2.02 and 0.2%, respectively. In addition, method detection limits were measured as 0.61 and 0.06 ng, respectively. A test of sample loss rate has also been made for Tedlar bag and vial by assessing the absolute amount of sample loss on the wall. By transferring the samples contained in Tedlar bag to various sizes of Tedlar bags, we measured differences in the absolute loss quantity due to such transfer. In addition, we also examined such loss mechanism as a function of elapsed time and light penetration rate for vial. As results, carbon dioxide and methane have shown about 2% of sample loss due to such contact. It is also noticed that the amount of loss with vial surface is lower than that of Tedlar bag. Therefore, field collection of greenhouse gases using various container types should be made more cautiously to minimize the possibility of sample loss and bias related to such loss.

Sound Transmission Loss of Double Panels(I) : A Double Wall with Air Cavity (이중판의 차음손실 I)

  • 강현주;김현실;김재승;김상렬
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.945-952
    • /
    • 1997
  • This paper shows the feasibility of the suggestion that the angle distribution of incident sound to panels might be gaussian, instead of the conventional uniform distribution in the analysis of transmission loss of panels. To prove the suggestion, the problems with the diffuse sound field in a reverberation room are examined by case studies and the comparision of the prediction with the measurement of sound transmission loss of walls are performed. The results of the comparision show good agreement between the two values.

  • PDF

Design and Performance Evaluation of the KIST Indoor Smog Chamber (실내 스모그 챔버의 설계 및 성능평가)

  • 배귀남;김민철;이승복;송기범;진현철;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.437-449
    • /
    • 2003
  • A multi-functional indoor smog chamber was designed and evaluated to investigate photochemical or water vapor reaction mechanisms of air pollutants. Various smog chamber experiments could be conducted using ambient air or purified air in this smog chamber. The smog chamber consisted of a housing, a Teflon bag, blacklights, injection ports, sampling ports, and utility facilities. The characteristics of light source, the wall losses of air pollutants, and the quality of purified air were experimentally investigated. The maximum NO$_2$ photolysis rate was 1.10 min$^{-1}$ . In a 2.5-m$^3$ Teflon bag, the wall losses of ambient $O_3$, NO, and NO$_2$ were 1.2~2.4$\times$10$^{-3}$ min$^{-1}$ , 0.7~2.0$\times$10$^{-3}$ min$^{-1}$ , and 0.4~2.0$\times$10$^{-3}$ min$^{-1}$ , respectively. The wall loss of ambient particles ranging 0.05 to 0.2 ${\mu}{\textrm}{m}$ was 1.8~5.4$\times$10$^{-3}$ min$^{-1}$ , which was slightly higher than those of ambient gaseous species. The purified air supply system provided high quality of air with NO$_{x}$ < 1 ppb, and total hydrocarbons < 5 ppb.b.

The Effects of Penicillin on the growth of Bacillus subtilis (Penicillin이 Bacillus subtilis의 생육에 미치는 영향)

  • 홍순덕
    • Microbiology and Biotechnology Letters
    • /
    • v.1 no.1
    • /
    • pp.19-23
    • /
    • 1973
  • This experiment was done to investigate the growth and the fine structural changes of Bacillus subtilis which were influenced by the penicillin with electromicroscope. The results were as follows; 1) The higher the concentration of penicillin the more prominent inhibition of the growth was observed. 2) The septa was not formed, derangements of synthesis of cell wall and cell membrane. 3) Cytoplasm was increased with swelling of cell body because of weakness of cell membrane induced by deranged synthesis of cell membrane. Some of the cells showed disruption of their membrane with loss of cytoplasm, remaining empty space, which suggest loss of cell function. 4) It can be suggested that penicillin had affected on the cell wall of Bacillus subtilis, and inhibited growth of the cell by deranging the formation of the cell wall.

  • PDF

Behavior of Coupling Shear Wall with New Openings (개구부 신설에 따른 병렬 전단벽의 거동특성)

  • Choi, Hyun-Ki;Choi, Youn-Cheul;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.152-160
    • /
    • 2008
  • Since wall system apartment used the shear wall as main lateral resistance member, installation of openings which causing section loss of walls may cause significant problem to structure. Also, there are few studies for inducing coupling beam or slabs which are occurred by installing openings. Therefore, this study planned isolated 2-story shear walls which are reduced three half-scale specimen to find out walls behavior characteristic. The test results showed that strength reduction caused by loss of effective section of walls and different result of stiffness and energy dissipation regarding to the coupling beam and coupling slabs.

EVALUATION OF HEAT-FLUX DISTRIBUTION AT THE INNER AND OUTER REACTOR VESSEL WALLS UNDER THE IN-VESSEL RETENTION THROUGH EXTERNAL REACTOR VESSEL COOLING CONDITION

  • JUNG, JAEHOON;AN, SANG MO;HA, KWANG SOON;KIM, HWAN YEOL
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.66-73
    • /
    • 2015
  • Background: A numerical simulation was carried out to investigate the difference between internal and external heat-flux distributions at the reactor vessel wall under in-vessel retention through external reactor vessel cooling (IVR-ERVC). Methods: Total loss of feed water, station blackout, and large break loss of coolant accidents were selected as the severe accident scenarios, and a transient analysis using the element-birth-and-death technique was conducted to reflect the vessel erosion (vessel wall thickness change) effect. Results: It was found that the maximum heat flux at the focusing region was decreased at least 10% when considering the two-dimensional heat conduction at the reactor vessel wall. Conclusion: The results show that a higher thermal margin for the IVR-ERVC strategy can be achieved in the focusing region. In addition, sensitivity studies revealed that the heat flux and reactor vessel thickness are dominantly affected by the molten corium pool formation according to the accident scenario.