• Title/Summary/Keyword: Wall Loss

검색결과 785건 처리시간 0.02초

그루브의 Trap 효과에 대한 CFD 해석: 제 1부 − 그루브 단면 형상의 변화 (CFD Analysis of Trap Effect of Groove in Lubricating Systems: Part I - Variation in Cross-Sectional Shape of Groove)

  • 홍성호
    • Tribology and Lubricants
    • /
    • 제32권3호
    • /
    • pp.101-105
    • /
    • 2016
  • Trap effect of groove is evaluated in a lubricating system using computational fluid dynamics (CFD) analysis. The simulation is based on the standard k-ε turbulence model and the discrete phase model (DPM) using a commercial CFD code FLUENT. The simulation results are also capable of showing the particle trajectories in flow field. Computational domain is meshed using the GAMBIT pre-processor. The various grooves are applied in order to improve lubrication characteristics such as reduction of friction loss, increase in load carrying capacity, and trapping of the wear particles. Trap effect of groove is investigated with variations in cross-sectional shape and Reynolds number in this research. Various cross-sectional shapes of groove (rectangular, triangle, U shaped, trapezoid, elliptical shapes) are considered to evaluate the trap effect in simplified two-dimensional sliding bearing. The particles are assumed to steel, and defined a single particle injection condition in various positions. The “reflect” boundary condition for discrete phase is applied to the wall boundary, and the “escape” boundary condition to “pressure inlet” and “pressure outlet” conditions. The streamlines are compared with particles trajectories in the groove. From the results of numerical analysis in the study, it is found that the cross-sectional shapes favorable to the creation of vortex and small eddy current are effective in terms of particle trapping effect. Moreover, it is found that the Reynolds number has a strong influence on the pattern of vortex or small eddy current in the groove, and that the pattern of the vortex or small eddy current affects the trap effect of the groove.

기주의 열음향진동에 관한 연구 (A Study on the Thermoacoustic Oscillation of an Air Column)

  • 권영필;이병호
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.253-261
    • /
    • 1987
  • 본 논문에서는 이러한 점들을 보완하여 Fig.1에 도시한 Rijke 관에서 나선형 가열기에 의한 음향력의 발생량을 계산하고 기주진동을 일으키는데 필요한 가열량을 계산하고 기주진동을 일으키는데 필요한 가열량을 구하였다. 이론을 뒷받침하기 위 하여 실험을 하고 결과를 비교 검토하였다.

Morphological and Hemodynamic Parameters for Middle Cerebral Artery Bifurcation Aneurysm Rupture Risk Assessment

  • Qin, Hao;Yang, Qixia;Zhuang, Qiang;Long, Jianwu;Yang, Fan;Zhang, Hongqi
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권5호
    • /
    • pp.504-510
    • /
    • 2017
  • Objective : To investigate the morphological and hemodynamic parameters associated with middle cerebral artery (MCA) bifurcation aneurysm rupture. Methods : A retrospective study of 67 consecutive patients was carried out based on 3D digital subtraction angiography data. Morphological and hemodynamic parameters including aneurysm size parameters (dome width, height, and perpendicular height), longest dimension from the aneurysm neck to the dome tip, neck width, aneurysm area, aspect ratio, Longest dimension from the aneurysm neck to the dome tip (Dmax) to dome width, and height-width, Bottleneck factor, as well as wall shear stress (WSS), low WSS area (LSA), percentage of LSA (LSA%) and energy loss (EL) were estimated. Parameters between ruptured and un-ruptured groups were analyzed. Receiver operating characteristics were generated to check prediction performance of all significant variables. Results : Sixty-seven patients with MCA bifurcation aneurysm were included (31 unruptured, 36 ruptured). Dmax (p=0.008) was greater in ruptured group than that in un-ruptured group. D/W (p<0.001) and the percentage of the low WSS area ($0.09{\pm}0.13$ vs. $0.01{\pm}0.03$, p<0.001) were also greater in the ruptured group. Moreover, the EL in ruptured group was higher than that in unruptured group ($6.39{\pm}5.04$ vs. $1.53{\pm}0.86$, p<0.001). Multivariate regression analysis suggested D/W and EL were significant predictors of rupture of MCA bifurcation aneurysms. Correlation analyses revealed the D/W value was positively associated with the EL (R=0.442, p<0.01). Conclusion : D/W and EL might be the most two favorable factors to predict rupture risk of MCA bifurcation aneurysms.

Parametric study of porous media as substitutes for flow-diverter stent

  • Ohta, Makoto;Anzai, Hitomi;Miura, Yukihisa;Nakayama, Toshio
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권2호
    • /
    • pp.111-125
    • /
    • 2015
  • For engineers, generating a mesh in porous media (PMs) sometimes represents a smaller computational load than generating realistic stent geometries with computer fluid dynamics (CFD). For this reason, PMs have recently become attractive to mimic flow-diverter stents (FDs), which are used to treat intracranial aneurysms. PMs function by introducing a hydraulic resistance using Darcy's law; therefore, the pressure drop may be computed by test sections parallel and perpendicular to the main flow direction. However, in previous studies, the pressure drop parallel to the flow may have depended on the width of the gap between the stent and the wall of the test section. Furthermore, the influence of parameters such as the test section geometry and the distance over which the pressure drops was not clear. Given these problems, computing the pressure drop parallel to the flow becomes extremely difficult. The aim of the present study is to resolve this lack of information for stent modeling using PM and to compute the pressure drop using several methods to estimate the influence of the relevant parameters. To determine the pressure drop as a function of distance, an FD was placed parallel and perpendicular to the flow in test sections with rectangular geometries. The inclined angle method was employed to extrapolate the flow patterns in the parallel direction. A similar approach was applied with a cylindrical geometry to estimate loss due to pipe friction. Additionally, the pressure drops were computed by using CFD. To determine if the balance of pressure drops (parallel vs perpendicular) affects flow patterns, we calculated the flow patterns for an ideal aneurysm using PMs with various ratios of parallel pressure drop to perpendicular pressure drop. The results show that pressure drop in the parallel direction depends on test section. The PM thickness and the ratio of parallel permeability to perpendicular permeability affect the flow pattern in an ideal aneurysm. Based on the permeability ratio and the flow patterns, the pressure drop in the parallel direction can be determined.

Characteristics of the Infection of Tilletia laevis Kuhn (syn. Tilletia foetida (Wallr.) Liro.) in Compatible Wheat

  • Ren, Zhaoyu;Zhang, Wei;Wang, Mengke;Gao, Haifeng;Shen, Huimin;Wang, Chunping;Liu, Taiguo;Chen, Wanquan;Gao, Li
    • The Plant Pathology Journal
    • /
    • 제37권5호
    • /
    • pp.437-445
    • /
    • 2021
  • Tilletia laevis Kuhn (syn. Tilletia foetida (Wallr.) Liro.) causes wheat common bunt, which is one of the most devastating plant diseases in the world. Common bunt can result in a reduction of 80% or even a total loss of wheat production. In this study, the characteristics of T. laevis infection in compatible wheat plants were defined based on the combination of scanning electron microscopy, transmission electron microscopy and laser scanning confocal microscopy. We found T. laevis could lead to the abnormal growth of wheat tissues and cells, such as leakage of chloroplasts, deformities, disordered arrangements of mesophyll cells and also thickening of the cell wall of mesophyll cells in leaf tissue. What's more, T. laevis teliospores were found in the roots, stems, flag leaves, and glumes of infected wheat plants instead of just in the ovaries, as previously reported. The abnormal characteristics caused by T. laevis may be used for early detection of this pathogen instead of molecular markers in addition to providing theoretical insights into T. laevis and wheat interactions for breeding of common bunt resistance.

샘플러에 따른 측정 위치별 원소탄소의 농도 비율 (Ratio of Elemental Carbon Concentrations for Respective Measurement Locations according to the Sampler)

  • 차원석;김은영;최성원;최수연
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.461-472
    • /
    • 2021
  • Objectives: This study was conducted to determine the differences in EC concentrations according to the type of sampler by measuring and analyzing EC. Methods: Elemental carbon was measured in diesel engine vehicles and at the roadside. Using NIOSH method 5040, a cassette was coupled to 37 mm and 27 mm quartz filters and measurements were performed 21 times. There were 14 types of measurement methods, and polystyrene, polypropylene, and metal samplers were evenly placed inside the movable chamber. Results: The results measured using the 37 mm conductive cassette (closed/open) and the IOM sampler made of conductive materials showed a higher ratio than the other results. When the 37 mm conductive cassette was measured with the lid open, it showed a statistically significantly higher ratio than with other measurement methods (p<0.05). Conclusions: Checking the EC concentration a total of 21 times at each ratio based on the concentration of the 3-stage polystyrene cassette, it was statistically significantly higher when the 37 mm conductive cassette was open. This same cassette also showed a slightly higher EC concentration when closed. It was ascertained that some DEE was collected on the cassette wall surface due to the electrical conductivity of the polystyrene cassette, resulting in sample loss. Since EC is composed of fine particles, it is thought that electrical conductivity may affect its concentration.

폴리머 콘크리트를 이용한 엘리베이터 기인 구조 진동저감 성능 연구 (Study on Elevator Induced Structural Vibration Reduction Performance Using Polymer Concrete)

  • 염지혜;김정진;박준홍
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.90-94
    • /
    • 2021
  • 주거지에서의 정숙함에 대한 관심이 높아짐에 따라 구조물에서 발생하는 소음을 최소화할 필요가 있다. 중요한 소음원 중 하나는 엘리베이터 작동 소음이다. 엘리베이터는 층 사이에서 작동하며 인근 생활 공간에 상당히 성가신 소리를 생성한다. 입주민들에게 성가심을 유발하는 주요 소음원으로 인식되고 있다. 엘리베이터는 층간 이동을 위해 여러 위치에서 건물 구조에 지지되어 있다. 본 연구에서는 지지 위치에 폴리머 콘크리트를 사용하여 진동을 감소시키는 것을 실증하였다. 시멘트 콘크리트와 폴리머 콘크리트에 지지했을 때의 진동 발생량을 측정 및 비교하여 소음 저감 성능을 평가하였다. 폴리머 콘크리트는 승강로를 모방한 벽에 삽입되는 형태로 제작되었다. 브라켓에 충격진동을 인가하고 진동전달크기를 측정하였다. 감쇠비는 과도응답의 정규화 및 곡선맞춤을 통해 평가하였고, 각 레진 혼합 질량비에 대하여 비교하였다. 폴리머 콘크리트를 사용하여 구조적 강성에 대한 손실 없이 효과적인 방식으로 진동 발생을 감소시킬 수 있다.

후퇴익형 형상의 와류발생기가 있는 핀휜 유동의 전열 및 유동 특성 분석에 관한 수치적 연구 (Numerical Study on Heat Transfer and Flow Characteristics of Pin Fin with Swept Airfoil Shape Vortex Generator)

  • 이창형;오영택;배지환;이득호;김귀순
    • 한국추진공학회지
    • /
    • 제23권4호
    • /
    • pp.28-34
    • /
    • 2019
  • 본 연구에서는 터빈 냉각에 널리 사용되는 핀-휜 배열에 대한 연구를 진행하였다. 본 연구에서 원형 튜브 전방에 익형 와류발생기가 위치하며, 익형 단면 형상은 NACA-9410을 사용하였다. 본 논문에서는 와류 발생기가 있는 핀-휜 배열 유동의 전열 성능과 유동 특성을 수직인 방향으로 변화시키며 기존의 핀-휜 유동과 비교하였다. 레이놀즈수 영역은 6000, 10000 그리고 15000 세 가지를 계산하였다. 전산 해석은 상용 프로그램인 ANSYS v18.0 CFX, 난류 모델은 $k-{\omega}$ SST를 사용하였다. 결과적으로 전열 성능은 최대 5.8% 증가하였고 압력 손실은 1% 미만으로 증가하였다.

'김광석 다시 그리기 길'의 장소 만들기와 장소성 (The Process of Place-making and the Placeness of the 'Kim Gwang-seok Road' in Daegu)

  • 박순호
    • 한국경제지리학회지
    • /
    • 제23권4호
    • /
    • pp.438-453
    • /
    • 2020
  • 본 연구에서는 인위적인 장소 만들기의 대표적인 사례인 '김광석 다시 그리기 길'을 대상으로 장소 만들기 과정과 그 과정에서의 주체들의 역할과 상호관계를 고찰하고 나아가서 장소성을 분석하고자 한다. 과거 방천시장과 신천대로 옹벽 사이의 골목길은 김광석 컨셉에 착안한 약 10여 년간의 도시재생 사업을 통하여 김광석의 추모공간이자 예술문화공간으로 뿌리내리게 되었다. 그러나 2010년대 후반의 지나친 관광명소화로 기존의 장소성이 약화된 반면에 문화상업공간의 특성이 강화되면서 장소성이 변화하고 있다. 이러한 장소성의 변화는 새롭게 형성되기 시작한 커뮤니티의 해체에 따른 지속가능한 발전의 동력 상실의 원인이 되고 있다. 이러한 문제점을 극복하기 위해서는 최우선적으로 기존 커뮤니티의 역량 및 내재된 사회자본과 장소자산을 새로운 방향으로 확대 재생산할 수 있는 내생적 거버넌스를 구축하여야 할 것이다.

Necrotrophic Fungus Pyrenophora tritici-repentis Triggers Expression of Multiple Resistance Components in Resistant and Susceptible Wheat Cultivars

  • Andersen, Ethan J.;Nepal, Madhav P.;Ali, Shaukat
    • The Plant Pathology Journal
    • /
    • 제37권2호
    • /
    • pp.99-114
    • /
    • 2021
  • Tan spot of wheat, caused by Pyrenophora tritici-repentis (Ptr), results in a yield loss through chlorosis and necrosis of healthy leaf tissue. The major objective of this study was to compare gene expression in resistant and susceptible wheat cultivars after infection with Ptr ToxA-producing race 2 and direct infiltration with Ptr ToxA proteins. Greenhouse experiments included exposure of the wheat cultivars to pathogen inoculum or direct infiltration of leaf tissue with Ptr-ToxA protein isolate. Samples from the experiments were subjected to RNA sequencing. Results showed that ToxA RNA sequences were first detected in samples collected eight hours after treatments indicating that upon Ptr contact with wheat tissue, Ptr started expressing ToxA. The resistant wheat cultivar, in response to Ptr inoculum, expressed genes associated with plant resistance responses that were not expressed in the susceptible cultivar; genes of interest included five chitinases, eight transporters, five pathogen-detecting receptors, and multiple classes of signaling factors. Resistant and susceptible wheat cultivars therefore differed in their response in the expression of genes that encode chitinases, transporters, wall-associated kinases, permeases, and wound-induced proteins, among others. Plants exposed to Ptr inoculum expressed transcription factors, kinases, receptors, and peroxidases, which are not expressed as highly in the control samples or samples infiltrated with ToxA. Several of the differentially expressed genes between cultivars were found in the Ptr resistance QTLs on chromosomes 1A, 2D, 3B, and 5A. Future studies should elucidate the specific roles these genes play in the wheat response to Ptr.