• 제목/요약/키워드: Wall Loss

검색결과 785건 처리시간 0.022초

조립형 건식벽체의 차음성능 개선 공법에 관한 연구 (Method of how to improve transmission loss of dry walls)

  • 김경호;전진용;김성훈;이형기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.719-724
    • /
    • 2013
  • In the case of newly developed stud which has more performance of sound transmission loss, it is expected that sound would transmit through runner than stud. so we developed construction method of runner and stud. As a result, sound transmission loss is improved about 2 dB by using this method. But this construction method could be applied to only newly developed stud. In addition, sound leak of wall joint is about 2 dB, and it could be improved by using rubber gasket at joint.

  • PDF

수직관내 유리알-물 유동의 압력손실 및 열전달 성능 (Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube)

  • 김내현;김정식;이윤표
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 춘계학술발표회 초록집
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

투과손실을 이용한 틸팅차량의 실내소음 예측 (Prediction of Interior Noise for Tilting Train by using Transmission Loss)

  • 김재철
    • 한국철도학회논문집
    • /
    • 제10권4호
    • /
    • pp.405-408
    • /
    • 2007
  • In this paper, we describe the analysis of interior noise for tilting train that is being developed in Korea. Tilting train is made of composite material to reduce the car body's weight and attached a self-steering system on bogie to improve curving performance. However, the acoustic performance (Transmission Loss) of such material is worse than the materials of conventional train, such as aluminum, steel and so on. Therefore, we measure the transmission loss of side wall/floor of tiling train and predict the interior noise for tilting train using its measuring results.

교통환기력이 작용하는 터널 내 벽면마찰계수 추정을 위한 프로그램 로직 개발 (Development of a programming logic to estimate the wall friction coefficient in vehicle tunnels with piston effects)

  • 김효규;최판규;류지오;이영훈
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.39-53
    • /
    • 2018
  • 일반적으로 터널 내 총환기저항계수는 입출구 손실계수, 벽면마찰계수 그리고 급격한 확대나 축소단면 등에 의해 발생하는 부차적 손실계수의 총합으로 구성된다. 개통 전 터널의 경우는 가동 중인 환기팬을 중단하게 되면, 터널 내 풍속은 총환기저항력에 의해 감소하는 현상이 나타난다. 즉, 속도감쇄법은 개통 전 터널에서 비교적 안정적이면서도 손쉽게 터널 내 벽면마찰계수를 추정하는 방법이다. 그러나 기존의 선행연구에서 환기팬의 가동을 중단 후 수렴되는 풍속이 음수일 경우는 속도감쇄법에 따른 벽면마찰계수의 추정이 곤란한 특성이 있다. 반면 교통환기력이 작용하는 공용 중인 터널에서는 좀더 복잡한 과정을 거치지만, 합리적인 벽면마찰계수를 추정할 수 있다. 본 연구에서는 교통환기력의 측정변수를 최소화할 수 있는 방법을 제안하였고, 공용 중 터널에 적용할 수 있는 방법을 고찰하였다. 또한 환기팬 정지 후 터널 내 풍속이 감소하는 동안에 외부 자연풍의 급격한 변화가 발생하여도 교통환기력이 일정할 경우에 대하여, 교통환기력의 증분을 계산할 수 있는 방법과 터널 내 벽면마찰계수를 추정할 수 있도록 동적 시뮬레이션이 가능한 프로그램 로직을 개발하였다.

페라이트 소재변수에 따른 아이솔레이터 특성 연구 (Characteristics of Isolator for material parameter)

  • 전동석;이홍열;김동영;이상석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.119-122
    • /
    • 2003
  • This paper describes characteristics for insertion losses of Isolator have an effect on material parameter. One purpose of the paper is to present insertion loss on this resonator for magnetic loss, dielectric loss, magnetic field and saturation magnetization. Another is to study the effect of propeller resonator on response characteristics. In this paper, the analysis and measurement of the response characteristics were carried out for the isolator prototype. The measurement results agreed on the simulation results and acquire insertion loss $0.18\;{\sim}\;0.24dB$, return loss 27dB, isolation 27dB and bandwidth 500MHz on this condition saturation magnetization 550G, dielectric loss 0.0004, magnetic loss 20 and dielectric constant 14.

  • PDF

Dynamic Analysis of the Piston Slap Motion in Reciprocating Compressors

  • Kim, Tae-Jong
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.411-412
    • /
    • 2002
  • Piston-cylinder system are widely used in power engineering applications. In reciprocating refrigeration compressors, where extremely low friction losses are required, ringless pistons are being used to diminish the friction between piston rings and cylinder wall. Since the ringless piston has the freedom of lateral motion there is a potential danger that it will occasionally hit the cylinder wall while moving up and down along it's axis. A good design must therefore provide a smooth and stable reciprocating motion of the piston and ensure that the fluid film separating the piston from the cylinder wall is maintained all times. And the compromise between refrigerant gas leakage through the piston-cylinder clearance and the friction losses is required utilizing a dynamic analysis of the secondary motion for the high efficiency compressor. To this end, the computer program is developed for calculating the entire piston trajectory and the lubrication characteristics as functions of crank angle under compressor running conditions. The results explored the effects of some design parameters and operating conditions on the stability of the piston, the oil leakage, and friction losses.

  • PDF

건축물에 의한 TV주파수대 전자파장해의 평가 및 대책에 관한 연구 (A Study on the Evaluation and Countermeasure of Electromagnetic Interference due to Buildings in TV Frequency Band)

  • 박재석;김동일;박연준;이창우
    • 한국항해학회지
    • /
    • 제22권1호
    • /
    • pp.55-62
    • /
    • 1998
  • 본 논문에서는 TV 주파수에 있어서 건조물에 의해 발생하는 전자파장해를 평가하기 위해 건축물 주위의 산란전자계를 수치계산하였다. 건축물 외벽에 전파흡수체를 부분적으로 부착한 경우 콘크리트면의 노출면적과 반사전계강도와의 관계를 조사하였다. 계산된 산란 전자계로부터 DU 비를 구해 TV 고스트방지를 위하여 건축물 외벽에 부착할 전파흡수체에 요구되는 반사 감쇠량을 구하였다.

  • PDF

막냉각에 따른 추력실의 냉각 성능 (The Cooling Performance of Thrust Chamber with Film Cooling)

  • 김선진;정해승
    • 한국군사과학기술학회지
    • /
    • 제9권1호
    • /
    • pp.117-124
    • /
    • 2006
  • Experiments on film cooling were performed with a small scale rocket engine homing liquid oxygen (LOx) and Jet A-1(jet engine fuel). Film coolants(Jet A-1 and water) were injected through the film cooling injector. Film cooled length and the outside wall temperature of the combustor were determined for chamber pressure, and the different geometries(injection angle) with the flow rates of film coolant. The loss of characteristic velocity due to film cooling was determined for the case of film cooling with water and Jet A-1. As the coolant flow increases, the outside wall temperatures decrease but the decrease in the outside wall temperatures reduced over the 8 percent film coolant flow rate. The efficiency of characteristic velocity was decreased with the Increase of the film coolant flow rate.

역 사다리꼴 핀의 최적화 (Optimization of a Reversed Trapezoidal Fin)

  • 강형석
    • 대한기계학회논문집B
    • /
    • 제30권10호
    • /
    • pp.987-995
    • /
    • 2006
  • A reversed trapezoidal fin with the fluid in the inside wall is analyzed and optimized in this study. As a fin base boundary condition, the heat transfer from inside wall fluid to the fin base is considered. The values of fin base temperature with the variations of inside wall fluid convection characteristic number and fin base length are listed. The heat transfer, fin effectiveness, fin length and fin base height are optimized as a function of fin base length, convection characteristic number ratio, fin shape factor and fin volume.

Evaluation of Thermal Utilization of Dousing System in PHWR Nuclear Power Plant

  • Nam, S.D.;Ryu, J.I.
    • 한국분무공학회지
    • /
    • 제4권3호
    • /
    • pp.42-52
    • /
    • 1999
  • An effectiveness of thermal utilization of a dousing system in the 600 MW PHWR Nuclear Power Plant has been evaluated. The behavior and conditions of water droplet sprayed in a postulated accident conditions in containment configuration has been calculated. In this calculation, two pressure conditions with the consideration of obstruction area and containment wall effect has been established : one being the minimum containment pressure of 7 kPa(g) encountered for dousing shut off and the other being the containment design pressure 124 kPa(g). The results revealed that the effectiveness of the thermal utilization ranges from 93% to 97%. In the analysis on two cases without/with side wall effect in the containment building, the thermal utilization decreases with obstruction area from 89% to 85%, which satisfies the design criteria set for the containment pressure against the accident condition.

  • PDF