• Title/Summary/Keyword: Wall Loss

Search Result 785, Processing Time 0.027 seconds

A Study on the Flow Characteristics of a Sleeve-Jointed Adjusting Piece (슬리브 이음된 조정관에서의 유동 특성에 관한 연구)

  • Lee, Chang-Yong;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.145-152
    • /
    • 2021
  • The purpose of this study was to determine the optimal distances between pipes to minimize the pressure loss and turbulent intensity. This was accomplished by investigating the distances between sleeve-jointed pipes and the flow changes in pipes based on variations in the Reynolds (Re) number when installing adjusting pieces for the pipes. When the thickness tp of the sleeve-jointed piping was fixed at 5 mm and the pipe lengths Lp were 10, 50, 100, and 200 mm, the correlations with the velocity of the sleeve-jointed part, pressure distribution, length of the reattachment point in the recirculation area, and Re number were analyzed. The flow characteristic of the sleeve-jointed part from a laminar to a turbulent flow region was determined by setting the Re range to 200 ≤ Re ≤ 5,000. This was done by utilizing Ansys Fluent 18.1, which is a commercial program. The enlargement and contraction ratios of the sleeve-jointed part were 1.2 and 0.83, respectively, and the turbulent intensity of the sleeve downstream edge and pressure change both increased as the Re number increased while Lp remained constant. The fact that the flow on the sleeve wall surface was disturbed by tp resulted in losses in velocity energy. Therefore, the edge of the sleeve-jointed part was also effected. When Lp was 10 mm or less, the turbulent intensity of the edge part did not change significantly as the Re number increased. The reattachment point in the recirculation area did not appear at Lp of 10 mm or less and was not affected by the vortex. In the case of 3,000 ≤ Re, the reattachment length of the wall surface of the sleeve-jointed part was nearly constant as Lp increased.

A Case of Unresectable Gallbladder Cancer Treated with Chemotherapy Followed by Extended Cholecystectomy (항암화학요법에 이은 확대 담낭절제술로 치료한 절제 불가능한 담낭암)

  • Kwang Hyun Chung;Jin Myung Park;Jae Min Lee;Sang Hyub Lee;Ji Kon Ryu;Yong-Tae Kim
    • Journal of Digestive Cancer Research
    • /
    • v.1 no.2
    • /
    • pp.104-107
    • /
    • 2013
  • Gallbladder (GB) cancer is highly malignant neoplasm found in advanced stage and chemotherapy commonly plays a palliative role in GB cancer. We report a case of unresectable GB cancer treated with chemotherapy followed by extended cholecystectomy. Fifty-six-year-old male visited our hospital with weight loss and dyspnea on exertion. Computed tomography detected pulmonary embolism and diffuse GB wall thickening with para-aortic lymph node enlargement. The length of common channel was 23mm at magnetic resonance cholangiopancreatography which stands for anomalous union of the pancreaticobiliary duct. Anticoagulation was started for pulmonary embolism. GB wall mass was regarded as unresectable GB cancer with distant lymph node metastasis. Gemcitabine and cisplatin combination chemotherapy was carried out for 6 cycles. Primary tumor was stationary but multiple enlarged lymphnodes were almost completely disappeared. Extended cholecystectomy with hepaticojejunostomy was performed. Post-operative tumor stage was T3N1 (stage IIIB) and R0 resection was achieved. After operation he has no evidence of disease recurrence for 6 months.

  • PDF

Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements (현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.329-337
    • /
    • 2017
  • In USA and UK, the standards of both reverberation time and background noise level have been established for the appropriate aural environment in classrooms. In order to realize this, guidelines for architectural planning and interior finishing have been also suggested. However, in Korea, there has hardly been any guidelines for satisfying background noise criteria and investigation about sound insulation performance of current walls of classrooms. The present study investigates the structure of outer wall and walls between classrooms of two middle schools in order to analyze the sound insulation performance against both exterior and interior noises. Acoustic parameters including transmission loss, standardized sound level difference, and signal to noise ratio have been measured and analyzed for sound insulation performance of walls and flanking noises. As a result, concerning the walls in between classrooms, it was found that walls of dry construction have greater sound insulation performance rather than the walls of wet construction especially in mid and high frequency bands. Also, It was revealed that thermopane, insulated pair glass, of outer walls, has greater sound insulation performance than the double window consisted of two single pane glass. Regarding flanking noises, the standards were exceeded when all windows, or windows and doors front onto corridor were opened. It denotes that students could be disturbed with the sound transmission by the interior noises.

Design of a Waveguide Band-Pass Filter Using a Modified H-type Resonant Iris (변형된 H-형 공진 아이리스를 이용한 도파관 대역통과 여파기 설계)

  • Park, Kyoung-Je;Choi, Tae-Ho;Lee, Jong-Ig;Kim, Byung-Mun;Cho, Young-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.347-353
    • /
    • 2018
  • In this paper, we studied a design method for a band-pass waveguide filter with a modified H-type resonant iris (RI) placed in a thin transverse wall of a rectangular waveguide. The horizontal straight gap at the center of a conventional H-shaped iris is modified to a U-shaped one to increase the equivalent capacitance, and the equivalent inductance is improved by changing the vertical two straight slots into C-shaped ones. From some simulation results for the frequency response of the proposed RI, it was observed that the proposed iris was advantageous for reducing its size and having better cutoff, compared to typical H-shaped one. Equivalent inductance, capacitance, and quality factor of the proposed RI were extracted to analyze its performance. A third-order band pass filter using the proposed modified H-shaped iris was designed and, it was observed that the filter operated in the frequency range of 9.18-9.84 GHz with its insertion loss of 0.3 dB and return loss of 14 dB.

The physiological and degradational characteristics of Fomers fomentarius (말굽버섯균의 생리적 특성과 부후특성)

  • Kim, Yu-I;Chai, Jyung-Ki
    • Journal of Mushroom
    • /
    • v.2 no.4
    • /
    • pp.200-206
    • /
    • 2004
  • The optimal temperature for mycelial growth the F. fomentarius was $30^{\circ}C$ and the range of the temperature for mycelial growth wsa about 10~30. The optimal pH for the growth was 4.0. The percentage of weight loss percentage wsa 17.4%. The percentage of WEC extractives wsa increased to 2.24%. The observation of micromorphological showed that the detected cell wall were erosive and thinning as typical degradation pattern of white-rot fungi.

  • PDF

Development of Depth-Damage Function by Investigating Flooded Area with Focusing on Building Damage (피해설문조사 기반의 도시지역의 침수심별 피해 추정함수 개발 -건물피해를 중심으로-)

  • Kim, Sang Ho;Kim, Byung Sik;Lee, Chang Hee;Chung, Jae Hak
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.8
    • /
    • pp.717-728
    • /
    • 2014
  • In this study, we developed a depth-damage function based on flood damage survey with focusing on building damage in urban area. We designed items for the questionnaire survey to develop a depth-damage function which estimates the amount of damage based on inundation depth targeting Dongducheon, Korea, which has experienced severe inundation damage due to significant flooding in July 2011. Based on the survey of the area, we developed a depth-damage function and used this to estimate the real amount of damage on buildings in the inundation area. To assess the damage on buildings, we categorized buildings into two groups; namely residential buildings and commercial buildings. Also, in order to calculate the real amount of damage caused by flooding, properties and detailed damaged items were sub-divided into two groups for the survey; facilities loss (wall paper, floor paper, painting, electrical facilities, and boilers) and furnishing loss (furniture, electronic products, and daily necessities. We expect this study on the process for developing depth-damage function and on the investigation research for flooded area to help in the efficient implementation of all kinds of disaster management policies and the attainment of a society safe from disaster.

Fabrication and Physical Properties of Tiles Recycled Waste Glass (폐유리를 재활용한 타일 제조 및 물리적 특성)

  • Kim, Young-Kil;Jung, Yeon-Gil;Song, Jun-Baek;Shin, Min-Chul;Lee, Hee-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.3 s.274
    • /
    • pp.193-197
    • /
    • 2005
  • Wall and floor tiles were fabricated by a dry pressing method using waste glass and clay. The physical properties of the tiles such as absorption, bulk density, porosity, compressive strength, and abrasion loss are investigated with the firing temperature and glass contents. The physical properties are improved with increasing the firing temperature and glass contents. The composition containing the glass of $70 wt%$ and fired at $1050^{\circ}C$ for 2 h has the good properties. The optimal properties obtained in the tiles are the water absorprion of about $0.9\%$, the bulk density of about $2.3\;g/cm^3$, the apparent porosity of about $2.1 \%$, the compressive strength of about 210 MPa, and the abrasion loss of about 0.022 g, when the composition containing the glass of $70\;wt\%$ is fired at $1050^{\circ}C$. The physical proper1ies of tiles fabricated were enhanced compared to the commercial clay tiles, due to easy melting and densification of glassy phase during the firing process.

A New Frontier for Biological Control against Plant Pathogenic Nematodes and Insect Pests I: By Microbes (식물병원성 해충과 선충 방제의 새지평 I: 미생물)

  • Lee, Hae-Ran;Jung, Jihye;Riu, Myoungjoo;Ryu, Choong-Min
    • Research in Plant Disease
    • /
    • v.23 no.2
    • /
    • pp.114-149
    • /
    • 2017
  • World-wide crop loss caused by insect pest and nematode reaches critical level. In Korea, similar crop loss has been gradually augmented in the field and greenhouse due to continuous crop rotation. The current methods on controlling herbivorous insects and plant parasitic nematodes are mostly depended on agro-chemicals that have resulted additional side-effect including occurrence of resistant insects and nematodes, environmental contamination, and accumulation in human body. To overcome the pitfalls, microbe-based control method have been introduced and applied for several decades. Here, we revised biological control using by the bacteria, fungi, and virus in order to kill insect and nematode and to attenuate its virulence mechanism. The introduced microbes mainly secreted out the hydrolysing enzymes and toxic compounds to target host membrane or cell wall directly. Indirectly, the microbe-triggered plant innate immunity against insects and nematodes was also reported. In conclusion, we provide a new frontier of microbe-based environmentally friendly procedure and effective methods to manage insects and nematodes.

Evaluation of Detection Ability of a Quantitative Light-Induced Fluorescence Digital Device for Initial Secondary Caries Lesion (Quantitative Light-Induced Fluorescence-Digital을 이용한 와동 내벽의 초기 이차우식병소 탐지 능력 평가)

  • Kim, Young Seok
    • Journal of dental hygiene science
    • /
    • v.17 no.2
    • /
    • pp.116-122
    • /
    • 2017
  • The purpose of this study was to evaluate the detection ability of secondary caries using qunatitative light-induce fluorescence-digital (QLF-D) device. Twenty bovine teeth with cavity on surface were demineralized during 21 days for secondary caries lesion of cavity wall. After 21 days, cavity was filled using composite resin and cut the specimen in half with disc. Fluorescence loss of lesion on surface by time flow, cross sectional lesion, and lesion of filled or unfilled surface were analyzed using analysis software. ${\Delta}F$ (value of fluorescence loss) of the lesion on surface assessed by the QLF-D increased significantly over time up to 21 days. And ${\Delta}F$ value of lesion of filled surface is significantly lower than that of unfilled surface (p<0.001). ${\Delta}F$ of filled surface is 1.31 times of cross section lesion. The correlation of between ${\Delta}F$ of filled surface lesion and ${\Delta}F$ of cross section lesion was showed low agreement (0.026) and correlation of between ${\Delta}F$ of unfilled surface lesion and ${\Delta}F$ of cross section lesion was showed high agreement (0.613). In conclusion, secondary caries can be detected on surface using QLF-D. However, interference of fluorescence of filling material is the points to be especially considered for exact analysis of secondary caries lesion.

Prediction and Evaluation of Indoors Noise Level of Exhibition Room in Museum by Road Traffic Noise (도로교통소음으로 인한 박물관 전시실의 실내 소음레벨 예측 및 평가)

  • Lee, Kook-Hyun;Park, Yeong-Ji;Kim, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.787-794
    • /
    • 2010
  • Recently, with sudden increase of supplying rate of cars and quantity of goods transported, traffic noisy becomes one of important factors obstruct environment of exhibition and view facilities have purpose in calmness and unsatisfaction about this is high now. Therefore, in case of exhibition and view facilities, it has to be grasped that satisfaction degree about the noisy in and out of the exhibition room by performing effect valuation on traffic noisy from design step. However the level of internal noise cannot be measured at the design phrase of the structure due to the noise of traffic. Up until now a walls transmission loss, based on the law of mass, is predicted using this method. However measuring the internal sound level after actual construction reveals that there is a large difference from measurements made at the design stage, and it is very difficult to find a solution after the opening of the structure. From research looking from this perspective the internal sound level was predicted- calculating the internal sound absorption ability, using acoustic simulation and loss prevention of an insulated wall- based on data collected to evaluate the internal sound of an exhibition room at a Folk Museum adjacent to a freeway. The results of this research are considered to provide important data for the prediction of internal sound level at the time of construction of exhibition facilities similar to this.