• 제목/요약/키워드: Wall Inspection

검색결과 320건 처리시간 0.025초

원전 탄소강 배관의 액적충돌침식 손상에 대한 B-Scan 검사 및 수치해석적 분석 (A Study on the Thermal Hydraulic Analysis and B-Scan Inspection for LDIE Degradation of Carbon Steel Piping in a Nuclear Plant)

  • 황경모;이대영
    • Corrosion Science and Technology
    • /
    • 제11권6호
    • /
    • pp.218-224
    • /
    • 2012
  • Liquid droplet impingement erosion (LDIE) known to be generated in aircraft and turbine blades is recently appeared in nuclear piping. UT thickness measurements with both A-scan and B-scan UT inspection equipments were performed for a component estimated as susceptible to LDIE in feedwater heater vent system. The thickness data measured with B-Scan equipment were compared with those of A-Scan. Thermal hydraulic analysis based on ANSYS FLUENT code was performed to analyze the behavior of liquid droplets inside piping. The wall thinning rate and residual lifetime based on both existing Sanchez-Caldera equation and measuring data were also calculated to identify the applicability of the existing equation to the LDIE management of nuclear piping. Because Sanchez-Caldera equation do not consider the feature of magnetite formed inside piping, droplet size, colliding frequency, the development of new evaluation method urgently needs to manage the pipe wall thinning caused by LDIE.

구조물 내벽의 균열 검사를 위한 시스템 개발에 관한 연구 (A Study on the Development of the System for Inspecting Cracks in the Inner Wall for Structures)

  • 이상호;신동익;손영갑;이강문;마상준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.480-483
    • /
    • 1997
  • In this paper, we have proposed an automatic inspection system for cracks on the surface of a structure. The proposed system consists of the imaging system and the veh~cle system. The imaging system. a set of optical sensor, lens, illuminator, storage and their configuration, images the scene and store it on the hard disk. We adopted a linescan camera of 5000 pixel density to achieve high resolution without loss of simplicity. The vehicle system that moves the optical system IS ~mplemented by an AGV. The AGV moves forward at constant velocity and avoid obstacles to acquire a stable image. We have cmplemented an experimental system and have acquired images of the wall of hallway. The image is of 0.1-mmipixel resolution and the scanning time IS about 1 mlsec. The allow able scan.

  • PDF

내부그라우팅으로 미세균열이 보수된 철근콘크리트 시공이음부의 역학적 특성에 관한 연구 (Mechanical Behavior of Construction Joints in Reinforced Concrete Structures Filled Internally with Cement Pastes)

  • 오병환;김세훈;이근희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.217-225
    • /
    • 2003
  • Grouting internally with grout materials can repair the micro-cracks and micro-voids of construction joints more efficiently than injecting grouts from the surface of cracks. A new internal grouting method using perforated bundled-cables was developed in this study to enhance the structural integrity of the construction joints. The extensive experiments were performed to examine the mechanical behavior of construction joints which are repaired internally by the developed method. The tests were conducted for rectangular-shaped box wall structures and straight wall structures. The strength and permeability tests at grouted construction joints were conducted to evaluate the structural behavior of repaired construction joints. The present study indicates that the internal grouting method developed in this study enhances greatly the performance of construction joints and may be efficiently used for the leak-tight integrity of construction joints in concrete structures.

고층벽식구조 아파트에서 골조공사 공기단축을 위한 바닥 슬래브 및 지주의 해석 (Analysis of Floor Slab and Support for the Shortening of Construction Time in High-Rise Wall-Type Apartment Building)

  • 김영찬;권기상
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.141-147
    • /
    • 2002
  • 국내 주거의 주종인 아파트의 구조형식은 벽식 철근콘크리트조로 경제성 때문에 대부분 고층으로 지어지고 있다. 철근 콘크리트구조 건물을 구체공사비중 상당부분이 거푸집공사에 투입되고 있다. 구체공사의 공기(工期)는 층당 소요일수로 산정할 수 있는데 공사비 절감 및 공기단축을 통한 시공효율상의 향상을 위해서는 지주시스템의 효율적인 전용(轉用)이 필수적이라 할 수 있다. 본 연구에서는 벽식구조 아파트의 현장조사를 토대로, 현재 사용되고 있는 지주시스템 및 바닥슬래브에 대한 응력해석을 수행하고, 이를 분석하여 공기단축의 가능성을 검토하였다.

철근의 깊이, 굵기 및 간격이 GPR 신호에 미치는 영향 조사 (Examination on the influence of Depth, Size and Interval of Rebar on the Signal of Ground Penetrating Radar)

  • 김영주;이승석;안봉영;김영길
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.167-174
    • /
    • 2000
  • Ground penetrating radar(GPR) was applied for measuring depths, sizes and intervals of rebars embedded in concrete. A concrete wall was constructed for this study and a sand pool and a concrete block were used for simulation. Result of this study shows that GPR can be used for measuring rebar depths and intervals, even though it is limitary, but that measuring sizes is almost impossible. Simulation with the sand pool was helpful for research on the versatile rebar arrays though signal was not clear as real concrete wall. A concrete block with many cylindrical holes for inserting different sized rebars could not be used for simulator due to many unknown reflective waves. Antenna orientation must be perpendicular to rebars for large reflection signal.

  • PDF

Mander의 층상화 단면 해석방법을 이용한 철근콘크리트 전단벽체의 비선형해석 (Nonlinear Analysis of Reinforced Concrete Shear Wall Using Mander's Fiber Section Analysis Method)

  • 김기욱;박문호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.111-119
    • /
    • 2005
  • 철근콘크리트 전단벽 또는 플랜지 구조물의 해석시 비선형으로 인한 거동을 해석하여 파괴거동을 좀더 명확하고 신뢰성있게 예측하고자 하는데 본 연구의 목적이 있다. 콘크리트 응력-변형율 모델로는 Hognestad, Vallenas의 이론을 적용하고, 철근 응력-변형율 모델로는 Ramberg-Osgood 이론을 적용하였으며, 구속(confined) 및 비구속(unconfined)을 고려하여 비선형 해석을 수행하였다. 단면 해석 모델은 Mander가 제안한 층상화 단면해석을 적용하였고, 감마팩터를 고려한 새로운 변형율도를 이용하였다. 이러한 단면에 경계효과를 고려한 Boundary warping과 전단효과를 고려한 Shear warping 및 초기 균열을 고려한 경우(precracked)와 초기 균열이 발생하지 않은 경우(uncracked)로 구분하여 단면 해석을 시행하였다.

고강도 콘크리트 전단벽체에 사용된 각형강관의 효과 (Effects of High-Strength Concrete Shear Walls with Rectangular Steel Tubes)

  • 김명준;오종한;조순호;최기봉;조철호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권2호
    • /
    • pp.209-217
    • /
    • 1998
  • Compared to normal-strength concrete, high-strength concrete has the lower lateral expansion capacity caused by the higher elastic modulus and the lower internal crack characteristic. Therefore, the effect of the lateral confining action of hoops appears slowly. Nevertheless, it has been reported that the strength and deformation capacity of high-strength concrete is improved by well-distributed hoops. Due to that argument, this investigation has been compared and analyzed by the experimental works on the deformation capacity and the confinement mechanism of high-strength concrete shear wall of the high-rise building reinforced by rectangular steel tubes and rectangular hoops at both edges. It is suggested that, using high-strength concrete($500kgf/cm^2$, $700kgf/cm^2$), hoops should be replaced with rectangular steel tubes in order to prevent closely spaced hoops at the edge of the shear wall.

  • PDF

반복 횡하중을 받는 철근콘크리트 전단벽의 비선형 해석 (Nonlinear Analysis of Cyclic Lateral Forced RC Shear Wall)

  • 김건우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권5호
    • /
    • pp.161-168
    • /
    • 2010
  • 실무 및 연구에 있어서 반복하중을 받는 콘크리트 벽체의 변형 및 저항능력 그리고 재료의 변형율 등을 정확하게 평가할 수 있는 방법이 필요하다. 따라서 본 논문에서는 비선형 트러스 부재를 이용하여 반복 횡하중을 받는 철근콘크리트 벽체 또는 철근콘크리트 면부재를 모델링 하였다. 콘크리트와 배근된 철근은 각각 수직, 수평 그리고 대각선 비선형 부재를 이용해 모델링 되었다. 본 논문에서는 높이/폭 비가 1.2인 벽체를 예제로 선택하여 실험의 결과와 비교하였다. 비교를 위하여 주대각선 부재의 경로에 따른 4가지의 형상과 대각선 부재들의 배열에 따른 3가지 형상이 채택되어 실험 결과와 가장 근사한 모델링의 선택을 위해 평가를 실시하였다.

굴착심도 변화에 따른 원형수직구 Ring Beam의 거동분석 (Behavior Analyses of Ring Beam at Vertical Wall with Change of Excavation Depth)

  • 박진은;경갑수;이준호;윤철희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권5호
    • /
    • pp.116-124
    • /
    • 2008
  • 본 연구에서는 원형수직구 굴착에 따른 Ring Beam의 거동을 평가하기 위하여 현장계측 자료의 분석과 평가, 굴착심도 변화에 따른 Ring Beam의 응력 특성 등의 비교분석을 구조해석에 기초하여 평가하였다. 그 결과, Ring Beam의 거동은 현장계측 및 구조해석 결과에서 유사한 경향을 나타내는 것을 알 수 있었다. 이로부터 굴착심도 변화에 따른 Ring Beam 거동은 본 연구에서 제안한 구조해석에 의해 예측할 수 있는 것을 확인하였다.

합성율과 벽체두께가 합성지하벽의 전단거동에 미치는 영향 (The Effect of Composite Ratio and Wall Thickness on the Shear Behavior of Composite Basement Wall)

  • 서수연;김성수;윤용대
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.93-101
    • /
    • 2010
  • 도심지의 제한된 공간에서 대형 건축 지하구조물을 축조하기 위한 지하 굴토공사는 주변지반의 안정이 최우선 되어야 하며, 이를 위해서 흙막이 공사가 필수적으로 검토되어야 한다. 가설 흙막이 구조에서 응력부담재로 주로 사용되고 있는 H-Pile은 주열식 흙막이 벽체에서 지하외벽의 시공 이후에는 방치되므로 재료의 낭비를 초래하게 된다. 이를 개선하기 위하여 가설재인 H-Pile과 지하벽을 합성한 합성지하벽 공법이 개발되어 현재 많은 국내의 현장에 활용되고 있다. 본 연구에서는 지하합성벽의 전단내력을 평가하기 위하여 총 5개의 실험체를 제작하였다. 실험변수로는 전단연결재에 따른 합성율과 벽체 두께를 변수로 하여 실험을 실시하였으며, 기준식에서 제시하는 콘크리트 전단강도와 H-Pile의 전단강도를 실험값과 비교 분석하였다. 실험결과 합성율이 증가함에 따라 전단강도는 상승하지만 그 차이는 크지 않은 것으로 나타났다. 합성지하벽의 전단강도 산정시, 콘크리트 강재의 웨브 뿐만아니라, 강재플랜지의 기여도를 고려한 새로운 식을 제시하고 이를 이용한 계산결과와 실험결과를 비교한 결과 좋은 대응을 보이는 것으로 나타났다.