• Title/Summary/Keyword: Wall Impaction

Search Result 30, Processing Time 0.676 seconds

A Numerical Study on the Flow Fields in the Continuous Casting Mold with Electromagnetic Brake (EMBR이 적용된 연속주조 몰드 내부에서의 유동장 해석)

  • Ha M. Y.;Lee H. G.
    • Journal of computational fluids engineering
    • /
    • v.4 no.2
    • /
    • pp.47-56
    • /
    • 1999
  • We developed a computer program to simulate the flow field in the presence of electro-magnetic fields. The steady, two-dimensional conservation equations for mass and momentum were solved simultaneously with Maxwell equations for electro-magnetic fields. Using this program, a numerical analysis was carried out to analyze the fluid flow in the continuous casting mold with electromagnetic brake. The effects of magnetic fields size, nozzle angle and EMBR yoke position on the flow fields in the continuous casting were investigated in the present study. The flow fields with EMBR were compared with those without EMBR. We also investigated the distribution of tracer concentration as a function of time in order to calculate their residence time in the mold with EMBR. By controlling the flow fields properly using EMBR, we can prevent the direct flow impaction on the wall which can give a damage on the mold surface and reduce surface defects of stainless steel sheet products.

  • PDF

Analysis of the Impinging Spray Behavior Accompanying with Change of Phase (상변화를 동반한 충돌분무의 거동해석)

  • Song, Hong-Jong;Cha, Keun-Jong;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.852-859
    • /
    • 2000
  • The emission in the exhaust gas from diesel engine is effected by the fuel spray characteristics. The spray of D.I. diesel engine impinges on a piston cavity and a cylinder wall. It is very important to know exactly the distribution and behavior of the spray inside cylinder. The objective of this study is to develop more accurate evaporation model. The EPISO code was used to analyze the flow characteristics in the engine. The Wakil model and the Faeth model are applied to the EPISO code to analyze the behavior of impinging spray. And also experimental and numerical analysis were carried out. The spray behavior characteristics were investigated by changing injection pressure, ambient pressure and temperature. The behavior of impinging spray was strongly effected by the change of ambient pressure and temperature. The effects of evaporation and rebounding droplet should be considered.

Numerical Analysis of Geometric Effects on Spray Characteristics in Small Direct-injection Diesel Engines (소형디젤기관 내 충돌부의 기구학적 조건에 대한 분무특성의 수치적 해석)

  • 류성목;차건종;김덕줄;박권하
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.55-65
    • /
    • 1999
  • Many researches have been investigating small direct-injection diesel engines using the spray impacting on walls. Those systems have one or more raised pips to break-up the fuel and spread it widely toward a desired direction in a combustion chamber. In this study, the sizes and heights of the pips are determined by using a computational fluid dynamics code employing non-orthogonal grid systems. In order to find out the suitable pip-shape to a small chamber, the spray behaviors, occupied spary volumes and averaged droplets sizes are calculated with the variation of shape of the pip, such as, size and heights and inclined degree. The desired shape of the impinging land is proposed for the design of combustion system in small diesel engines.

  • PDF

The Effect of Extended Collision Model on a Spray (확장 충돌 모델이 분무계산에 미치는 영향)

  • 한진희;조상무;박권하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.181-191
    • /
    • 2002
  • Spray calculation has been studied to understand the behavior of the spray in a combustion chamber But the spray dispersion has not been predicted properly in a high velocity injection spray or a wall impaction spray. In this study the extended grazing collision model is applied to improve the problem. The gas phase is modelled by the Eulerian continuum conservation equations of mass, momentum, energy and fuel vapour fraction. The liquid phase is modelled following the discrete droplet model approach in Lagrangian form. The droplet distributions, penetration, width and gas flows are compared for the cases with or without extended model. The extended collision model makes the results better.

VISUALIZATION AND MEASUREMENT OF A NARROW-CONE DI GASOLINE SPRAY FOR THE IMPINGEMENT ANALYSIS

  • Park, J.S.;Im, K.S.;Kim, H.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • v.5 no.4
    • /
    • pp.221-238
    • /
    • 2004
  • Wall interactions of direct injection spray were investigated using laser-sheet imaging, shadowgraphy, wetted footprint and phase Doppler interferometry techniques. A narrow-cone high-pressure swirl injector is used to inject iso-octane fuel onto a plate, which has three different impact angles inside a pressurized chamber. Heated air and plate conditions were compared with unheated cases. Injection interval was also varied in the heated case to compare dry- and wet- wall impingement behaviors. High-speed macroscopic Mie-scattering images showed that presence of wall and air temperature has only minor effect on the bulk spray structure and penetration speed for the narrow-cone injector tested. The overall bulk motions of the spray plume and its spatial position at a given time are basically unaffected until a few millimeters before impacting the wall. The surface properties of the impact surface, such as the temperature, the presence of a preexisting liquid film also have a small effect on the amount of wetting or the wetted footprint; however, they have strong influence on what occurs just after impact or after a film is formed. The shadowgraph in particular shows that the plate temperature has a significant effect on vapor phase propagation. Generally, 10-20% faster horizontal vapor phase propagation is observed along the wall at elevated temperature condition. For impingement onto a preexisting film, more splash and evaporation were also observed. Contrary to some preconceptions, there is no significant splashing and droplet rebounding from surfaces that are interposed in the path of the DI gasoline spray, especially for the oblique impact angle cases. There also appears to be a dense spray front consists of large sac spray droplets in the oblique impact angle cases. The bulk of the spray is not impacted on the surface, but rather is deflected by it The microscopic details as depicted by phase Doppler measurements show that the outcome of the droplet impaction events can be significantly influenced. Only droplets at the spray front have high enough Weber numbers for wall impact to wet, splash or rebound. Using the sign of vertical velocity, the time-resolved downward droplets and upward droplets are compared. The Weber number of upward moving droplets, which seldom exceeds unity, also decreases as the impact angle decreases, as the droplets tend to impact less and move along the wall in the deflected spray plume.

Successful Removal of Endobronchial Lipoma by Flexible Bronchoscopy Using Electrosurgical Snare

  • Yun, Seong Cheol;Na, Moon Jun;Choi, Eugene;Kwon, Sun Jung;Lee, Seong Ju;Oh, Sun Hee;Cha, Eun Jung;Son, Ji Woong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.74 no.2
    • /
    • pp.82-85
    • /
    • 2013
  • A 62-year-old man with a chronic cough presented with atelectasis of the left upper lobe on chest X-ray. Chest computed tomography showed an atelectasis in the left upper lobe with bronchial wall thickening, stenosis, dilatation, and mucoid impaction. We performed bronchoscopy and found a well-circumscribed mass on the left upper lobe bronchus. The mass was removed by flexible bronchoscopy using an electrosurgical snare and diagnosed with lipoma. An endobronchial lipoma is a rare benign tumor that can be treated by a surgical or endoscopic approach. We report the successful removal of endobronchial lipoma via flexible bronchoscopic electrosurgical snare.

Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger (패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가)

  • Ji, Jun-Ho;Bae, Kwi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

Unconfined compressive strength property and its mechanism of construction waste stabilized lightweight soil

  • Zhao, Xiaoqing;Zhao, Gui;Li, Jiawei;Zhang, Peng
    • Geomechanics and Engineering
    • /
    • v.19 no.4
    • /
    • pp.307-314
    • /
    • 2019
  • Light construction waste (LCW) particles are pieces of light concrete or insulation wall with light quality and certain strength, containing rich isolated and disconnected pores. Mixing LCW particles with soil can be one of the alternative lightweight soils. It can lighten and stabilize the deep-thick soft soil in-situ. In this study, the unconfined compressive strength (UCS) and its mechanism of Construction Waste Stabilized Lightweight Soil (CWSLS) are investigated. According to the prescription design, totally 35 sets of specimens are tested for the index of dry density (DD) and unconfined compressive strength (UCS). The results show that the DD of CWSLS is mainly affected by LCW content, and it decreases obviously with the increase of LCW content, while increases slightly with the increase of cement content. The UCS of CWSLS first increases and then decreases with the increase of LCW content, existing a peak value. The UCS increases linearly with the increase of cement content, while the strength growth rate is dramatically affected by the different LCW contents. The UCS of CWSLS mainly comes from the skeleton impaction of LCW particles and the gelation of soil-cement composite slurry. According to the distribution of LCW particles and soil-cement composite slurry, CWSLS specimens are divided into three structures: "suspend-dense" structure, "framework-dense" structure and "framework-pore" structure.

Effect of Operating Pressure on the Heat Transfer and Particle Flow Characteristics in the Syngas Quench System of an IGCC Process (IGCC 합성가스 급속 냉각시스템의 운전 압력에 따른 열유동 및 입자 거동 특성 연구)

  • Park, Sangbin;Yang, Joohyang;Oh, Junho;Ye, In-Soo;Ryu, Changkook;Park, Sung Ku
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.1
    • /
    • pp.97-104
    • /
    • 2014
  • In a coal gasifier for IGCC, hot syngas leaving the gasifier at about 1550oC is rapidly quenched by cold syngas recycled from the gas cleaning process. This study investigated the flow and heat transfer characteristics in the gas quench system of a commercial IGCC process plant under different operating pressures. As the operating pressure increased from 30 bar to 50 bar, the reduced gas velocity shortened the hot syngas core. The hot fly slag particles were retained within the core more effectively, and the heat transfer became more intensive around the hot gas core under higher pressures. Despite the high particle concentrations, the wall erosion by particle impaction was estimated not significant. However, large particles became more stagnant in the transfer duct due to the reduced gas velocity and drag force under higher pressures.

Isolation and Characterization of Airborne Bacteria and Fungi in Indoor Environment of Elementary Schools (초등학교 실내환경에서 공기 중 세균과 진균의 분리 및 특성)

  • Kim, Na-Yeong;Kim, Young-Ran;Kim, Min-Kyu;Cho, Du-Wan;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.43 no.3
    • /
    • pp.193-200
    • /
    • 2007
  • Indoor airborne bacterial and fungal concentrations were examined at classrooms and corridors of 3 elementary schools in Ulsan. Airborne microorganisms were collected with an impaction-type air sampler using plate count agar and dichloran rose bengal chloramphenicol agar. During the semester, concentrations of bacteria ranged $168{\sim}3,887 MPN/m^3$ at classrooms and $168{\sim}6,339 MPN/m^3$ at corridors, while those of fungi ranged $34{\sim}389 MPN/m^3$ at classrooms and $91{\sim}507 MPN/m^3$ at corridors. The bacterial concentrations showed larger variations between situations and schools compared to those of fungi. When airborne bacteria were isolated and identified, 84% were observed as Gram-positive, and Micrococcus spp. was the most abundant group with 61% of tested isolates, followed by genus Staphylococcus with 10%. The Micrococcus spp. isolates, of which 75% were identified as M. luteus, appeared to be from human origins. The protective pigments and substantial cell wall of Micrococcus may provide selective advantage for their survival in the air. We also isolated and identified 15 genera of filamentous fungi. The most common culturable fungi were Cladosporium, Aspergillus and Penicillium, and these 3 genera were 69% of fungal isolates. Genus Stachybotrys, of which S. chartarum is a well known producer of many potent mycotoxins, was also detected from one of the schools. further systematic studies are necessary with an emphasis on species identification and mycotoxin production of isolated fungal genera, including Aspergillus, Penicillium, and Stachybotrys.