• Title/Summary/Keyword: Wake-up

Search Result 259, Processing Time 0.024 seconds

An Evaluation of Data Delivery Mechanisms in Clustered Sensor Networks (클러스터 기반 센서 망에서 데이터 전달 방법들의 성능 분석)

  • Park Tae-Keun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.3A
    • /
    • pp.304-310
    • /
    • 2006
  • This paper evaluates the performance of three types of data delivery mechanisms in clustered sensor networks, as a basic research to develop an energy efficient topology management scheme. In the first mechanism, one node per cluster(clusterhead) turns on its radio(or wakes up) to transmit and receive RTS/CTS/DATA/ACK messages, but in the second one, k nodes per cluster wake up and participate in the message exchange. In the last mechanism, clusterheads turn on the radio to exchange RTS/CTS messages, and if a clusterhead receives RTS containing its cluster m as a destination, it makes k nodes in the cluster hun on the radio to receive DATA and transmit ACK. Through simulation, we show the energy consumption of the three types of data delivery mechanisms as functions of the number of active nodes per cluster, offered load, and packet loss probability.

Effect of Foeniculum Vulgare (Fennel) on Sleep Quality of Menopausal Women: A Double-blinded, Randomized Placebo-controlled Trial

  • Afiat, Maliheh;Dizavandi, Fatemeh Rajab;Kargarfard, Leila;Vahed, Seyede Houra mosavi;Ghazanfarpour, Masumeh
    • Journal of Menopausal Medicine
    • /
    • v.24 no.3
    • /
    • pp.204-209
    • /
    • 2018
  • Objectives: Aim of present study was designed to investigate the soporific effect of fennel among menopausal women. Methods: The present double-blinded and placebo-controlled trial examined the fennel effect on Pittsburgh Sleep Quality Index (PSQI). Total score and relevant 7 components, including sleep duration, sleep latency, use of sleeping medication, subjective sleep quality, sleep disturbances, daytime dysfunction and habitual sleep efficiency among 50 menopausal women compared to control group within a 12-week follow-up. Results: The patients in both groups reported no certain side effects and all subjects completed the study. The mean actual sleep duration was 5 hours and 66 minutes. Intergroup comparison revealed no statistically significant differences in the mean total PSQI score (P = 0.439), subjective sleep quality (P = 0.826), habitual sleep efficiency (P = 0.127), sleep disturbances (P = 0.130), use of sleeping medication (P = 0.52) and daytime dysfunction (P = 0.439). A tendency toward significant between 2 groups was seen concerning the sleep duration (P = 0.059). Intergroup comparison showed significantly borderline levels (P = 0.059). Conclusions: The treatment of 12 weeks with fennel caused a slight effect that did not reach to significant. These findings should be considered cautiously because of small sample size, short-term follow-up and subjective measure of sleep quality.

A Study on the Tidal Energy Yield Capability according to the Yaw Angle in Jangjuk Strait (장죽수도에서의 요각변화에 따른 조류에너지 생산량에 관한 연구)

  • Tran, Bao Ngoc;Choi, Min Seon;Yang, Changjo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.982-990
    • /
    • 2019
  • The interest of researchers and governments in exploiting tidal energy resources is increasing. Jangjuk strait is a place with high tidal energy density potential and is therefore appropriate for the constructing of a tidal turbine farm. In this study, a numerical approach is presented to evaluate the current flow and power potential in Jangjuk strait with an ADCIRC model. Then, the tidal field characteristics are utilized as input parameters for tidal resource calculation with an in-house program. The 1 MW scale tidal energy converter devices are employed and arranged in 4 layouts to investigate the annual energy yield as well as flow deficit due to the wake ef ect at the surveyed area. The best-performed array generates an annual energy yield up to 12.96 GWh/year (without considering the wake effect); this value is reduced by 0.16 GWh/year when accounting for the energy loss caused by the flow deficit. Moreover, by altering the turbine yaw angle during the flood and ebb tides, the impacts of this factor on the energy extraction are analyzed. This indicates that the turbine array attains the maximum tidal power when the turbine yaw angle is at 346° and 164° (clockwise, to the North) for the spring and neap tide in turns.

Acoustic Doppler Current Profiler Bottom Tracking Survey of Flow Structures around Geumo Archipelago in the Southern Waters of Korea (ADCP bottom tracking에 의한 금오열도 주변의 해수유동)

  • Choo, Hyo-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.589-600
    • /
    • 2019
  • In order to investigate the flow structures around Geumo archipelago on Southern Waters of Korea, water movements were measured for 25 hours during spring tide in May and neap tide in September 2002 using ADCP (Acoustic Doppler Current Profiler) attached to a running boat. Dominant directions of ebb and flood current at spring tide are SE-NW, representing the average flow rate of approximately 40cm/s in the surface layer. However because of the topographical reason, the direction and speed of the flow in the narrow waterway sea area around the northwest of Gae Island were different. There was no notable baroclinic component of tidal flow at spring tide. This indicates that the sea area has been actively engaged in vertical mixing due to island wake or eddy due to narrow waterways, shallow water depth and rapid flow rate around archipelago. At neap tide, dominant directions of tidal flows are SSE-NNW and the average flow rate in the surface layer is about 85 percent of the spring tide. The duration and intensity of the flow direction are shorter and less dominant than the spring tide. It is expected that asymmetrical tidal mixing will occur due to vertical velocity shear and horizontal eddies. From daily mean tidal flows obtained from the ADCP observation, it was found that the northwest of Gae Island have flows in NW~NE, the west of Geumo Island have the average currents of up to 21 cm/s WSW~SSW and counterclockwise circulation or eddy currents are formed in the west of Sori Island.

Instruction Queue Architecture for Low Power Microprocessors (마이크로프로세서 전력소모 절감을 위한 명령어 큐 구조)

  • Choi, Min;Maeng, Seung-Ryoul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.56-62
    • /
    • 2008
  • Modern microprocessors must deliver high application performance, while the design process should not subordinate power. In terms of performance and power tradeoff, the instructions window is particularly important. This is because a large instruction window leads to achieve high performance. However, naive scaling conventional instruction window can severely affect the complexity and power consumption. This paper explores an architecture level approach to reduce power dissipation. We propose a low power issue logic with an efficient tag translation. The direct lookup table (DTL) issue logic eliminates the associative wake-up of conventional instruction window. The tag translation scheme deals with data dependencies and resource conflicts by using bit-vector based structure. Experimental results show that, for SPEC2000 benchmarks, the proposed design reduces power consumption by 24.45% on average over conventional approach.

Wireless Power Harvesting Techniques to Improve Time to Fly of Drone (무인항공기 비행시간 향상을 위한 무선 전력획득 기술)

  • Nam, Kyu-hyun;Jung, Won-jae;Jang, Jong-eun;Chae, Hyung-il;Park, Jun-seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1574-1579
    • /
    • 2016
  • This paper presents a self-powered sensor-node scheme using a RF wireless power harvesting techniques for improve drone time of flight. Sensor-node that is proposed is turned when two conditions satisfy: The one is input RF ID data from master-node should be same with sensor-node's ID, and the other one is RF wireless power harvesting system is turned on by hysteresis switch. In this paper, master-node's output is 26 dBm at 263 MHz. Maximum RF to DC power conversion efficiency is about 55% at 4-6 dBm input power condition (2 meter from master-node). The maximum RF wireless power harvesting range is about 13 meter form master-node. And power consumption of the sensor-node's load elements such as transmitter, MCU and temperature sensors is approximately average 15 mA at 5.0 V for 10 msec.

An Occupational Exposure Assessment and Melatonin Excretion Level of Electromagnetic Fields(EMFs) (전자파의 직업성 노출평가 및 멜라토닌 분비량에 관한 연구)

  • Kim, Yoon Shin;Cho, Yong Sung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.264-271
    • /
    • 1998
  • A pilot study was undertaken to examine the possible health effects of electromagnetic fields(EMFs). The purpose of this study was to investigate of the EMFs exposures of personal environment, 60Hz magnetic fields. An experimental study was performed for six weeks of January-February 1998 to compare changes in melatonin levels in urine of 20 subjects during their normal sleeping hours and each 20 subjects in occupational and non-occupational group measured personal 24-h continual exposure, using EMDEX II (for 40-800Hz, Enertech Consultant, Inc.). An urine samples were collected 3 times a day(before sleep or around 24:00 ; immediately after wake-up ; around noon) for an week from each subjects and analyzed by radioimmunoassay. This study did not significant difference for the subjective average melatonin levels between occupational and nonoccupational groups exposed to electromagnetic fields. The mean personal exposure levels of occupational group were $0.215{\mu}T$, whereas non-occupational group were $0.18{\mu}T$. Occupational group were exposed more highly while at work. Finally, this study would provide significant data for furture study of exposure assessment of magnetic fields. A large scale study concerning more detailed exposure assessment should provide important information on health risk assessment of MFs. Further study should provide information on the contribution of various sources and the relationship between melatonin and immune system activity.

  • PDF

An Experimental Study on Structural Behaviour of Asymmetric H Beam Slim floor under Load Condition in Fire (내화 피복된 비대칭 H형강을 적용한 슬림플로어 보의 재하가열조건 화재거동에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Hyung-Jun;Min, Byung-Youl;Lee, Jae-Sung;Park, Soo-Yong
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.63-71
    • /
    • 2011
  • When it comes to slim floor using asymmetric H-beam, it was designed that the steel member is embedded in concrete with relatively low thermal conductivity so as to minimize the deterioration of rigidity of steel member in fire. But given the bottom flange of asymmetric H-beam is directly exposed to the fire, the measure of applying the fireproof coating to improve the fire rate performance of slim floor beam was sought. The test was aimed at comparing the fireproof performance by adjusting the load ratio of 0.4 and 0.3, and The test was carried out to identify the 3-hour fire performance by reinforcing the beam as well as applying the fireproof coat, In the wake of comparing the specimen depending on variation of load ratio, lowering load ratio by 0.1 resulted in difference of 12 minutes and deflection was 39 mm. It was able to improve 12 minutes by reinforcing the beam and up to 102.4 mm in deflection.

Study on the low power consumption of active RFID tag system (저전력 능동형 RFID 태그 시스템에 대한 연구)

  • Kim, Ji-Tae;Lee, Kang-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1419-1435
    • /
    • 2015
  • In this study an active RFID system of low power consumption is proposed, for which we improved the tag collection algorithm of ISO/IEC 18000-7 standard and significantly reduced the tag collection time. We classified the type of power consumption according to the operating mode of active RFID and proposed the method which can accurately estimate battery life time. By calculating the power consumptions of proposed and current methods, we can compare the battery life times of both methods. Through this analysis we can demonstrate the superiority of the proposed method in battery life time.

Wind direction field under the influence of topography: part II: CFD investigations

  • Li, S.W.;Hu, Z.Z.;Tse, K.T.;Weerasuriya, A.U.
    • Wind and Structures
    • /
    • v.22 no.4
    • /
    • pp.477-501
    • /
    • 2016
  • Though hilly topography influences both wind speeds and directions aloft, only the influence on wind speeds, i.e. the speed-up effect, has been thoroughly investigated. Due to the importance of a model showing the spatial variations of wind directions above hilly terrains, it is worthwhile to systematically assess the applicability and limitations of the model describing the influence of hilly topographies on wind directions. Based on wind-tunnel test results, a model, which describes the horizontal and vertical variations of the wind directions separately, has been proposed in a companion paper. CFD (Computational Fluid Dynamics) techniques were employed in the present paper to evaluate the applicability of the proposed model. From the investigation, it has been found that the model is acceptable for describing the vertical variation of wind directions by a shallow hill whose primary-to-secondary axis ratio (aspect ratio) is larger than 1. When the overall hill slope exceeds $20^{\circ}$, the proposed model should be used with caution. When the aspect ratio is less than 1, the proposed model is less accurate in predicting the spatial variation of wind directions in the wake zone in a separated flow. In addition, it has been found that local slope of a hill has significant impact on the applicability of the proposed model. Specifically, the proposed model is only applicable when local slope of a hill varies gradually from 0 (at the hill foot) to the maximum value (at the mid-slope point) and then to 0 (at the hill top).