• Title/Summary/Keyword: Waiting Space

Search Result 148, Processing Time 0.021 seconds

A Study on the Architectural Planning of Clinical Practice Spaces at the College of Medicine (의과대학의 임상실습공간에 관한 건축계획 연구)

  • Choi, Kwangseok
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.4
    • /
    • pp.7-14
    • /
    • 2021
  • Purpose: This study summarized architectural planning data for clinical practice spaces for CPX/OSCE and Simulation spaces, through analysis of domestic and foreign literature and a survey of domestic colleges of medicine. Methods: This study analyzed the architectural planning elements of the clinical practice spaces of the college of medicine, through a literature review on the clinical practice space and the survey of four recently established colleges of medicine. Results: ① It is desirable to plan the floor plan type for Simulation and CPX/OSCE spaces as a corridor-separated type that separates the circulations between students and staff (faculty). ② The simulation area arranges their practice rooms around the control space where the circulation of the staff is made. Conversely, it is desirable to arrange the CPX/OSCE rooms around the test waiting room where students enter. ③ It is desirable to separate access to the staff and students to allow student control, and to install various support spaces facing the staff corridor to secure the movement of equipment and the flow of evaluators. ④ In the simulation area, the equipment stored in the storage must be set in each room before the practice according to the setting of delivery or surgery like, and the equipment that has been removed must be back, so the circulation is short and does not intersect with the student circulations. ⑤ Debriefing rooms, seminar rooms, etc. are arranged in the staff area for review and discussion of clinical situations where practice and evaluation have been completed. Implications: It is important to configure an appropriate movement system and spatial zoning for each space for simulation and CPX/OSCE.

Analysis of Institutional Limitations on Evacuation of Urban Railway Station Facilities and Guidelines (도시철도역 시설의 피난에 대한 제도적 한계점 분석과 가이드라인)

  • Yekyeong Shin;Okkyung Yuh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.4
    • /
    • pp.1-9
    • /
    • 2022
  • This study analyzes the institutional status related to 'evacuation' and 'firefighting' in underground subway stations, derives institutional limitations for 'evacuation' in underground subway stations, and proposes guidelines in terms of architectural space based on this. As a result of the study, the following points were derived. First, since similar standards are separately enacted in individual laws and it is difficult to grasp the standards and they are dualized, it is necessary to standardize and regulate the space where users stay according to the movement of urban railway users, limited to urban railways. Second, in order to use trains, a special procedure called 'ticketing' must be considered, and regulations on evacuation safety zones and evacuation stairs between the waiting room and the platform are required. Finally, if there is a platform at a depth of more than 30m underground, it is necessary to install an evacuation floor in accordance with standards similar to the current building law.

Healing Environment at the General Hospital Lobby Space -By comparison of the lobby plan type- (종합병원 로비공간의 치유환경에 관한 연구 -로비 평면형태의 비교를 중심으로-)

  • Lee, Yu-Jung;Oh, Joon-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.89-97
    • /
    • 2018
  • In the past, hospitals were planned with a minimum of public space for the sole purpose of treatment. On the other hand, modern hospitals have more public space as the importance of the healing environment increases and are planned taking into consideration the patients, guardians, and medical staff. In addition, the lobby shape is developed from a HALL type and planned as a STREET type or CONCOURSE type, increasing the public area. Unlike past hospitals, which were used as reception, waiting, and procedure spaces, modern hospitals are used as commercial, hobby, and cultural space. The purpose of the study was to evaluate the healing environment of the hospital lobby based on the shape of the plane surface by deducting the elements of general hospitals' healing environment from preceding studies as a framework. The hospital lobby is an important place where many actions occur. Therefore, 3 types of cases were evaluated based on the plane form. As a result of the study, the STREET type showed a better healing environment than the HALL type, but the accessibility, roof garden, and resting place showed similar results. Because the case was based on a large general hospital, which had sufficient planned space, the factor has little to do with the style of the lobby. Among the STREET types, the linear atrium showed a better result in terms of the sense of space and inflow effect of natural lighting than the four-sided atrium because the linear atrium has large open volume ratio. When the lobby plane is the HALL type, a cross section of the courtyard had a large open volume ratio. Therefore, the shape of the cross section is as important as the plane form of the lobby.

A study on Classification of Temporarily Access Group about Sanitation Workers in Nuclear Medicine Department (핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰)

  • Yoo, Jae-Sook;Jang, Jeong-Chan;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.50-56
    • /
    • 2012
  • Purpose: Those who access to the nuclear medicine department are classified as radiation workers, temporarily access group, and occasional access group as defined by the atomic energy law. The radiation workers and temporarily access people wear a personal radiation dosimeter for checking their own radiation absorbed dose periodically. However, because of the sanitation workers, classified as temporarily access group, who are working in the nuclear medicine department are moved in a cycle with other departments and their works are changeful, it is hard to control their radiation absorbed dose. Thus, this study is going to examine the state of the sanitation worker's radiation absorbed dose, and then make sure whether they are classified as temporarily access group or not. Materials and methods: In the first instance, the first sanitation worker who works in vitro laboratory and PET room and the second sanitation worker who works in gamma camera rooms (invivo room) wore radiation dosimeter-OSL(Optically Stimulated Luminescence)- to measure their own radiation absorbed dose during work time from May to June 2011. Secondly, this study was taken place 5 places in gamma camera rooms, 2 places in PET bed room, operating room, waiting room and cyclotron room in PET and 4 places in vitro laboratory. And then to measure the radiation space dose rate, it is measured 10 times each of places as sanitation worker's work flow by using radiation survey meter. Results: The radiation absorbed dose on OSL of the first c who works in vitro laboratory and PET room and the second one who works in gamma camera rooms are 0.04, 0.02 mSv per month respectively. That means the estimated annual radiation absorbed doses are less than 1mSv as 0.48, 0.24 mSv/yr respectively. The radiation space dose rates as sanitation worker's work flow using survey meter are 0.0037, 0.0019 mSv/day, so the estimated annual radiation absorbed dose are 0.93, 0.47 mSv/yr respectively. The weighted exposure dose of first sanitation worker of each places are 1.62% in cyclotron room, 3.88% in waiting room, 2.39% in operating room, 81.01% in bed room of PET and 11.01% in vitro laboratory. The weighted exposure dose of second sanitation worker of each places are 45.22% in radiopharmaceutical laboratory, gamma 30.64% in camera rooms, 15.65% in waiting room, 8.49% in reading room. Conclusion: The annual radiation absorbed doses on OSL of both sanitation workers are less than 1 mSv per year and the annual radiation absorbed doses by using survey meter are less than 1mSv either, but close up to 1 mSv. Thus, to clarify whether the sanitation workers are temporarily access group or not, and to be lessen their s radiation absorbed dose, they should be educated about management of radiation and modified their work flow or work time appropriately, their radiation absorbed dose would be lessen certainly.

  • PDF

The Actual Experiences of the Living World among Cancer Patients (암환자의 생활세계 경험)

  • Yang, Jin-Hyang
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.1
    • /
    • pp.140-151
    • /
    • 2008
  • Purpose: The purpose of this study was to understand the meanings and nature of living in the world among cancer patients. The present study adopted a hermeneutic phenomenological method which was developed by van Manen. Method: The participants for this study were 5 men and 6 women, who were over the age of 20 with admission or a follow up visit in the medical or surgical department. Data were collected by using in-depth interviews and observations from February to September, 2007. The contents of the interviews were tape-recorded with the consent of the subject. Result: The essential themes that fit into the context of the 4 existential grounds of body, time, space and other people were: a body that cannot be restored, a body that endures and lives, waiting in uncertainty, a valued calculation for the living day, being in a world of invisible power, reestablishing relationships, and reflection on his or her life. Conclusion: These findings revealed that living in the world is affected to varying degrees by the cancer. It is important for nurses to identify and take care of disabilities and to support the reorientation in the disintegrated life situation. The result of this study can give nurses some insight into these experiences and help promote empathetic care.

Bluetooth Low-Energy Current Sensor Compensated Using Piecewise Linear Model

  • Shin, Jung-Won
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.283-292
    • /
    • 2020
  • Current sensors that use a Hall element and Hall IC to measure the magnetic fields generated in steel silicon core gaps do not distinguish between direct and alternating currents. Thus, they are primarily used to measure direct current (DC) in industrial equipment. Although such sensors can measure the DC when installed in expensive equipment, ascertaining problems becomes difficult if the equipment is set up in an unexposed space. The control box is only opened during scheduled maintenance or when anomalies occur. Therefore, in this paper, a method is proposed for facilitating the safety management and maintenance of equipment when necessary, instead of waiting for anomalies or scheduled maintenance. A Bluetooth 4.0 low-energy current-sensor system based on near-field communication is used, which compensates for the nonlinearity of the current-sensor output signal using a piecewise linear model. The sensor is controlled using its generic attribute profile. Sensor nodes and cell phones used to check the signals obtained from the sensor at 50-A input currents showed an accuracy of ±1%, exhibiting linearity in all communications within the range of 0 to 50 A, with a stable output voltage for each communication segment.

Chest Wall Reconstruction with a Transverse Rectus Abdominis Musculocutaneous Flap in an Extremely Oversized Heart Transplantation

  • Yim, Ji Hong;Eom, Jin Sup;Kim, Deok Yeol
    • Archives of Reconstructive Microsurgery
    • /
    • v.23 no.2
    • /
    • pp.89-92
    • /
    • 2014
  • An 8-year-old girl diagnosed with dilated cardiomyopathy and Russell-Silver syndrome was admitted to our pediatric intensive care unit due to low cardiac output and multiple-organ dysfunction. The patient was placed on the heart transplant waiting list and extracorporeal membrane oxygenation was performed as a bridge to transplantation. After 17 days, heart transplantation was performed. The donor was a 46-year-old female (weight, 50 kg; height, 150 cm). The donor:recipient weight ratio was 3.37:1. Because the dimension and volume of the recipient's thoracic cage were insufficient, the sternum could not be closed. Nine days after transplantation, the patient underwent delayed sternal closure. To obtain adequate space, we left the sternum 4.5 cm apart from each margin using four transverse titanium plates. A transverse rectus abdominis musculocutaneous flap was chosen to cover the wound. Due to the shortage of donors, a size-mismatched pediatric heart transplantation is sometimes unavoidable. Closure of the opened sternum of a transplant recipient can be challenging. Sternal reconstruction after an extremely oversized heart transplantation with transverse titanium plate fixation and a musculocutaneous flap can effectively achieve sternal closure and stability.

A Study on the Survey about the Interior Design of General Hospital's Ultrasonography (종합병원별 초음파검사실의 실내디자인에 대한 이용자 평가에 관한 연구)

  • Kim Su-Jung;Choi Young-Mi;Lee Sang-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.6
    • /
    • pp.39-47
    • /
    • 2004
  • A general hospitals change continuously and rapidly, the way of growth and change becomes an important factor in the interior design. For this purpose, it compares and analyzes the image between different general hospital's ultrasonography with content level in the interior design to aspect investigating the preferences of the patient. Also the field survey on the real users was carried out, asking what kind of interior design you like in the general hospital ultrasonography. These research materials can be utilized for the practice application in the interior design of general hospital ultrasonography with the analyzing each available space. In the survey result, the point on the users needs things which are considered as the most important aspect for the fundamental data for the reasonable design planning and the basic principles of the modeling plan in the hospital's ultrasonography. So this study is to investigate and analyze the characteristics of the waiting area, way finding, color, lighting, counter design. This study would apply to interior design for the modeling of general hospital's ultrasonography.

Experiences of Admission for Critically Ill Patients in ICU (중환자실 환자의 입원 경험)

  • Yang, Jin-Hyang
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.1
    • /
    • pp.149-162
    • /
    • 2008
  • Purpose: The purpose of this study was to understand the meanings and nature of ICU admission experienced among patients with critical illness. The present study adopted a hermeneutic phenomenological method which was developed by van Manen. Methods: The participants for this study were 6 men and 3 women, who were over the age of 20 with ICU admission period more than 3 days. Data were collected by using in-depth interviews and observations from March, 2007 to September, 2007. The contents of the interviews were tape-recorded with the consent of the subject. Results: The essential themes that fit into the context of the 4 existential grounds of body, time, space and other people were as follows: a body that cannot react the way it wants, a wave of fear and insecurity everywhere, a struggle to survive, coming out from death's door, loss of time path, a long and continued waiting until escaping, more of machinery room than a patient's room, existence of life and death, an abyss of suffering seen thru another patient, taken care of by a doctor, trust and distrust, family, the ultimate safe zone. Conclusion: Critically ill patients in ICU experienced feelings of discomfort, unsafety, and insecurity. The result of this study can give nurses some insight into these experiences and help promote empathetic care.

  • PDF

A Study on the Change and Characteristics of Stereotyped Japanese Elementary School in Meiji Era - Focusing on the Standard Drawings by Japanese Ministry of Education - (명치기(明治期) 일본(日本) 소학교건축(小學校建築)의 표준화 과정 및 특성에 관한 연구 - 문부성 제정 표준도 분석을 중심으로 -)

  • Lee, Jeong-Woo;Shim, Woo-Gab
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.2
    • /
    • pp.27-38
    • /
    • 2008
  • This study aims to examine Japanese elementary school architecture in Meiji Era, in which Japanese modern education system was settled down and the school architecture flourished by mass construction of stereotyped school buildings. It is assumed that stereotyped school architecture is due to the influence of the standard drawings made by Japanese Ministry of Education, therefore standard drawings could be a key to understand the characteristics of the stereotyped school buildings in Meiji Era. In this perspective this study attempts to analyze 4 standard drawings and interpret it in relation to regulations and design guidelines for school architecture in that time. As results of this study the change and characteristics of stereotyped school architecture in Meiji Era are clarified in several categories. They are as follows : the deviation of classroom and corridor, the change of classroom size fixing to 4 kan(間) by 5 kan(間), the absolute use of north-lacing single corridor type block-plan, and the change of other space such as waiting room(控所), special instruction room, auditorium and gymnasium.