• Title/Summary/Keyword: WS이

Search Result 655, Processing Time 0.024 seconds

Behaviors of Arsenic in Paddy Soils and Effects of Absorbed Arsenic on Physiological and Ecological Characteristics of Rice Plant lll. Effect of Water Management on As Uptake and the Growth of Rice Plant at As Added Soil (토양중(土壤中) 비소(砒素)의 행동(行動)과 수도(水稻)의 비소흡수(砒素吸收)에 의(依)한 피해생리(被害生理) 생태(生態)에 관(關)한 연구(硏究);Ⅲ.물관리(管理)가 수도의 비소흡수(砒素吸收) 및 생육(生育)에 미치는 영향(影響))

  • Lee, Min-Hyo;Lim, Soo-Kill-H
    • Korean Journal of Environmental Agriculture
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 1987
  • A pot experiment was conducted to find out the effect of water management on the growth and uptake of arsenic and inorganic nutrients of rice plant at As added soil. The arsenic were added to soil at the levels of As 0, 10, 50, 100 and 150 ppm, respectively. Water management was done with two ways: intermittent irrigation from ten days after transplanting, and continuous submersion until harvest. Higher soil As levels increased As content in plant but reduced growth rate. Aresenic content in plant was considerably reduced with intermittent irrigation compared to continuous submersion. Rice growth showed also same trend. With increasing As levels in soil, N content in plant was increased but P, K, Ca, Mg, $SiO_2$, Fe and Mn content in plant were tend to be decreased. These inorganic nutrients in plant were also much absorbed in continuous submersion compared to intermittent irrigation. Soil pH was slightly increased with increasing As levels in soil while soil Eh has no relationship with soil As levels. On the other hand, soil pH was higher in the treatment of continuous submersion than that of intermittent irrigation but soil Eh showed reverse trend. With increasing As levels in soil, water soluble-As and Ca-As fractions in soil tend to be increased with continuous submersion, but these fractions has no tendency with intermittant irrigation.

  • PDF

Germination and Growth of Oaks (Quercus serrata, Q. mongolica, Q. variabilis) Seedlings by Gradient of Light Intensity and Soil Moisture (광도와 토양수분 구배(勾配)에 따른 참나무류(Quercus Serrata, Q. mongolica, Q. variabilis)치수(稚樹)의 발아 및 성장)

  • Beon Mu-Sup
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.4
    • /
    • pp.183-189
    • /
    • 2000
  • This study was carried out to analyze ecophysiological responses for seedling of Quercus serrata, Quercus mongolica and Quercus variabilis that are the typical species of deciduous broadleaved forests in Korea. And executed experiments in the climatic control room to provide necessary information to ecological forest management and methods of natural regeneration through the analysis of seedling responses. The details of experimental analysis were growth processes of 4 months after seeding that vary with the condition of three light intensity[relative light intensity(RLI) 8%, 20%, 52%] and three soil moisture[water suction(WS) Ψ=100 hPa, Ψ=280 hPa, Ψ=330 hPa] gradient, growth factors after harvesting and the nutrition condition of leaves. The results of this study are followings: 1) Early growth was prosperous after germination for the species which have more weight of acorn. 2) The formation of lammas shoot was favourable with Q. variabilis and Q. mongolica. And the rate of the occurrence was the highest in the RLI 20%, and it was remarkably reduced in the RLI 8%. 3) As the height growth of seedling of all 3 species were greater in the RLI 20% and 8% than that of the RLI 52%, they showed strong shade tolerance. 4) The increase of light intensity promoted the diameter at root collar growth, and development of main and lateral roots with all 3 species. 5) It showed that the increase of light intensity in the experimental radiation condition raised special leaf area weight(mg/cm$^2$) and leaf area productivity(mg/cm$^2$). Consequently, these resulted in the increase of leaf thickness and total dry biomass per the unit area of leaf. 6) As the increase of light intensity, the minerals contents of leaves such as N, P and K were lowered, and the increase of soil moisture resulted in the increase of P, K, Ca and Mg.

  • PDF

A Study of Satisfaction About Dental technician's Post and Laboratory in Great Cities (일부(一部) 대도시(大都市) 지역(地域) 치과기공사(齒科機工士)의 직업(職業) 및 직업장(職業場) 만족도(滿足度)에 관한 조사연구(調査硏究))

  • Lee, Tea-Jung;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.7 no.1
    • /
    • pp.41-51
    • /
    • 1985
  • This study has been to survey the present situation of satisfaction to the occupation and dental laboratory by means of selscting 200 dental technicians who are woked in Pusan, Deagu, Kwangju, Deajun. Questionaires were distributed to them and the summerized results were as follows; 1. In general, the dental technician's satisfaction of the occpation was revealed as moderate(Mn, 2.83), the dental technician's satisfaction of the laboratory was revealas moderate(Mn, 2.80). The highest degree item out of the satisfaction of occpation was the outlook(Mn, 3.23), and the lowest degree item was the advancement and the rise to a high position(Mn, 2.22). The highest degree item out of the satisfaction of laboratory was dental material(Mn, 3.07), and the lowest degree item was the equipment of dust collection(Mn, 2.49) 2. By age, the highest degree item out of the satisfaction of occpation was 30 to 43 group(Mn, 3.28), 50 and over group was the lowest degree item(Mn, 2.89). The highest degree item out of the satisfaction of laboratory was 40 to 50 group(Mn, 3.10), the lowest degree item was 35 to 39 group(Mn, 2.88). 3. By school career, the satisfaction of occpation and dental laboratory were higher in the graduated college group than the graduated highschool group. 4. By personal health state, the highest degree item of the satisfaction of occpation was the health group(Mn, 3.25). The highest degree item of the satisfaction of laboratory was the unhealthy group(Mn, 3.07). 5. By religion, the satisfaction if iccupation of laboratory ws higher in the religious group than the non-religious group. 6. By job career, the highest degree item of occupation satisfaction was 15 to 20 years group(Mn, 3.27), the lowest degree item was 20 and over group(Mn, 3.02). The highest degree item out of the satisfaction of laboratory was 15 to 20 years group(Mn, 3.05), The lowest degree item was 7 to 10 years group (Mn, 2.90). 7. By job position, the highest degree item out of satisfaction of occupation was the chief of laboratory group(Mn, 3.33), the head of laboratory group was the lowest degree item(Mn, 3.07). The hightest degree item out of the satisfaction of laboratory was the head of laboratory group(Mn, 3.10), the lowest degree item was the chief of laboratory group(Mn, 2.88). 8. By the place of employment, the degree of occpational satisfaction by items was found that the highest degree in the group engagel in general hospital(Mm, 3.43), the group engaged in dental clinic and hospital(Mn. 3.24), and the dental laboratory group(Mn. 3.14) in order. The difference among the group was significant emough(P<0.05). The highest degree item out of the satisfaction of laboratory was dental laboratory group(Mn. 2.70). The difference among the group was significant emough(P<0.01). 9. By monthly salary, the highest degree item out of the satisfaction of occupation was ₩500,000 to 600,000 group(Mn. 3.32), the lowest degree item was ₩600,000 and over group(Mn, 3.07). The highest degree item out of the laboratory satisfaction was ₩100,000 to 200,000 group(Mn, 3.03), the lowest degree group was ₩300,000 to 400,000 group(Mn, 2.95). 10. As compared with the degree of satisfaction according to job satisfaction, the highest degree item out of the occupational satisfaction was much satisfied group(Mn, 3.65), the lowest degree item was non-satisfied group(Mn, 2.68). The difference among the group was significant enough(P<0.05). The highest degree item out of the satisfaction of laboratory was non-satisfied group(Mn, 30.9), the lowest degree item was satisfied group(Mn, 2.84). The difference among the group was significant enough(P<0.01).

  • PDF

A study on the calibration characteristics of organic fatty acids designated as new offensive odorants by cryogenic trapping-thermal desorption technique (유기지방산 신규악취물질에 대한 저온농축 열탈착방식 (Thermal desorber)의 검량특성 연구)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Im, Moon-Soon;Ju, Do-Weon
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.488-497
    • /
    • 2009
  • In this study, analytical methodology for several organic fatty acids (OFA: propionic acid (PA), butyric acid (BA), isovaleric acid (IA), and valeric acid (VA)) designated as new offensive odorants in Korea (as of year 2010) was investigated along with some odorous VOCs (styrene, toluene, xylene, methyl ethyl ketone, methyl isobutyl ketone, butyl acetate, and isobutyl alcohol). For this purpose, working standards (WS) containing all of these 13 compounds were loaded into adsorption tube filled with Tenax TA, and analyzed by gas chromatography (GC) system thermal desorber interfaced with. The analytical sensitivities of organic fatty acids expressed in terms of detection limit (both in absolute mass (ng) and concentration (ppb)) were lower by 1.5-2 times than other compounds (PA: 0.24 ng (0.16 ppb), BA: 0.19 ng (0.11 ppb), IA: 0.15 ng (0.07 ppb), and VA: 0.28 ng (0.13 ppb)). The precision of BA, IA, and VA, if assessed in terms of relative standard error (RSE), maintained above 5%, while the precison of other compounds were below 5%. The reproducibility of analysis improved with the aid of internal standard calibration (PA: $1.1{\pm}0.4%$, BA: $10{\pm}0.46$, IA; $12{\pm}0.3%$, VA: $4{\pm}0.1%$), respectively. The results of this study showed that organic fatty acid can be analyzed using adsorption tube and thermal desorber in a more reliable way to replace alkali absorption method introduced in the odor prevention law of the Korea Ministry of Environment (KMOE).

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.