• 제목/요약/키워드: WIND FLOWS

검색결과 308건 처리시간 0.026초

차체 기밀특성이 선루프 성능에 미치는 영향 연구 (Study of Effects of Body Leakage on Performance of a Sunroof)

  • 이영림
    • 한국자동차공학회논문집
    • /
    • 제9권3호
    • /
    • pp.201-209
    • /
    • 2001
  • Some passenger cars with sunroofs open at tilted positions experience reverse flows into cabin rooms and wind noises much louder compared to other cars. In this study, flows around open sunroofs are numerically studied with the variations of body leakage. The effects of body leakage on ventilation and wind noise of a sun roof are examined, in particular. Furthermore, flow visualization, pressure, and noise measured from wind tunnel and road tests are presented. The results show that too small body leakage results in poor performance of ventilation and generates high wind noise around a sunroof. It is therefore very important to secure an adequate body leakage from the early design stage to achieve better performance of a sunroof as well as passengers' comfort related to HVAC(Heating, Ventilation, and Airconditioning).

  • PDF

다중규모 모델을 이용한 도시 지역 흐름과 초미세먼지(PM2.5) 분포 특성 연구: Part I - 상세 흐름 분석 (A Numerical Study on the Characteristics of Flows and Fine Particulate Matter (PM2.5) Distributions in an Urban Area Using a Multi-scale Model: Part I - Analysis of Detailed Flows)

  • 박수진;최원식;김재진
    • 대한원격탐사학회지
    • /
    • 제36권6_3호
    • /
    • pp.1643-1652
    • /
    • 2020
  • 본 연구에서는 국지예보시스템(LDAPS)과 전산유체역학(CFD) 모델을 접합하여, 부산 중구 광복동에 소재한 건물 밀집 지역의 상세 흐름을 조사하였다. 도시 지역 기상에 대한 보다 현실적인 수치 모의를 위해 기상청이 현업으로 운용하는 LDAPS 결과로부터 기상 요소(풍향, 풍속, 온위)를 추출하여 CFD 모델의 초기·경계장으로 사용하였다. LDAPS로부터 추출한 기상 요소(U, V)는 공간 선형 보간법을 이용하여 CFD 모델의 수평·연직 격자에 맞게 내삽하였고, 공간 선형 보간법을 이용해 내삽한 온위는 CFD 모델의 각 격자점에서 온도로 변환된다. 본 연구에서는 건물 옥상에서 측정한 3차원 초음파 풍향·풍속계에서 측정한 풍속과 풍향을 이용하여 수치 모의 결과를 검증하였다. 대상 기간(2020년 6월 22일) 동안 측정 지점(PKNU-SONIC)에서는 바람이 약하게 나타났고, 새벽 시간에는 북동풍과 북서풍이 불었으며, 주간에는 주로 남동풍이 불었다. LDAPS-CFD 접합 모델은 측정 풍향과 풍속을 유사하게 수치 모의하였다. 07시에는 동북동쪽에서 유입되는 흐름이 지형과 건물에 의해 변화하였고, PKNU-SONIC 지점에서 수치 모의된 풍향(동남동풍)은 측정 풍향과 유사하다. 19시에는 남동쪽에서 유입되는 흐름이 PKNU-SONIC 지점까지 유입되어 측정 풍향과 유사하게 모의하였다.

등밀도 수로흐름에서 의 난류모형 비교 (Comparison of Turbulence Models in Homogeneous Channel Flows)

  • 이종찬;최병호
    • 한국해양학회지
    • /
    • 제30권1호
    • /
    • pp.13-26
    • /
    • 1995
  • Blumberg와 Mellor(1987)의 2 방정식 난류모형, Bleackadar(1962)의 1 산정식을 이용한 1 방정식 난류모양 및 Prandtl(1925)의 혼합거리식을 이용한 0 방정식 난류모 양을 일련의 등밀도 문제에 적용 비교하였다. 구체적으로 일정유량이 주어진 수심이 급변하는 수로의 흐름, 유한수로에서 의 조류의 연직구조 및 일정수심 수로에서 의 정 상상태 취송류 문제에 대하여 비교되었다. 불규칙한 수심에 일정유량이 주어진 수로 흐름 및 점모양을 이용한 조류의 수치실험에서는 적용된 난류모양 모두 거의 비슷한 결과를 보였으며, 비교적 관측된 유속구조와 부합하는 좋은 결과를 보였다. 그러나 정 상상태의 취송류 경우에는 2 방정식만이 관측된 유속과 부합하는 유속구조를 재현하 였으며, Blackadar의 l 산정식을 이용한 1, 0 방정식 난류모형은 수면근처의 유속을 관측치보다 작게 계산하였다. 이류항 및 수평확산항의 영향이 작은 조류 및 취송류의 경우, 2 방정식 난류모형에 의한 연직와점성계수 이류항 및 수평확산항의 영향이 작은 조류 및 취송류의 경우, 2 방정식 난류모양에 의한 연직와점성계수 및 특성길이의 연 직분포는 중간수심에서 최대값을 갖는 포물형이었으며, Blackadar의 l 산정식을 사용 한 1, 0 방정식 난류모형에 의한 연직와점성계수 및 혼합특성길이의 연직분포는 수면 에서 최대인 선형에 가까웠다.

  • PDF

Characteristics of downslope winds in the Liguria Region

  • Burlando, Massimiliano;Tizzi, Marco;Solari, Giovanni
    • Wind and Structures
    • /
    • 제24권6호
    • /
    • pp.613-635
    • /
    • 2017
  • Strong downslope windstorms often occur in the Liguria Region. This part of North-Western Italy is characterised by an almost continuous mountain range along its West-East axis consisting of Maritime Alps and Apennines, which separate the Padan Plain to the North from the Mediterranean Sea to the South. Along this mountain range many valleys occur, frequently perpendicular to the mountain range axis, where strong gap flows sometimes develop from the top of the mountains ridge to the sea. In the framework of the European projects "Wind and Ports" and "Wind, Ports, and Sea", an anemometric monitoring network made up of 15 (ultra)sonic anemometric stations and 2 LiDARs has been realised in the three main commercial ports of Liguria. Thanks to this network two investigations are herein carried out. First, the wind climatology and the main statistical parameters of one Liguria valley have been studied through the analysis of the measurements taken along a period of 4 years by the anemometer placed at its southern exit. Then, the main characteristics of two strong gap flows that occurred in two distinct valley of Liguria are examined. Both these studies focus, on the one hand, on the climatological and meteorological characterisation of the downslope wind events and, on the other hand, on their most relevant quantities that can affect wind engineering problems.

Will CFD ever Replace Wind Tunnels for Building Wind Simulations?

  • Phillips, Duncan A.;Soligo, Michael J.
    • 국제초고층학회논문집
    • /
    • 제8권2호
    • /
    • pp.107-116
    • /
    • 2019
  • The use of computational fluid dynamics (CFD) is becoming an increasingly popular means to model wind flows in and around buildings. The first published application of CFD to both indoor and outdoor building airflows was in the 1970's. Since then, CFD usage has expanded to include different aspects of building design. Wind tunnel testing (WTT) on buildings for wind loads goes back as far as 1908. Gustave Eiffel built a pair of wind tunnels in 1908 and 1912. Using these he published wind loads on an aircraft hangar in 1919 as cited in Hoerner (1965 - page 74). The second of these wind tunnels is still in use today for tests including building design ($Damljanovi{\acute{c}}$, 2012). The Empire State Building was tested in 1933 in smooth flow - see Baskaran (1993). The World Trade Center Twin Towers in New York City were wind tunnel tested in the mid-sixties for both wind loads, at Colorado State University (CSU) and the [US] National Physical Laboratory (NPL), as well as pedestrian level winds (PLW) at the University of Western Ontario (UWO) - Baskaran (1993). Since then, the understanding of the planetary boundary layer, recognition of the structures of turbulent wakes, instrumentation, methodologies and analysis have been continuously refined. There is a drive to replace WTT with computational methods, with the rationale that CFD is quicker, less expensive and gives more information and control to the architects. However, there is little information available to building owners and architects on the limitations of CFD for flows around buildings and communities. Hence building owners, developers, engineers and architects are not aware of the risks they incur by using CFD for different studies, traditionally conducted using wind tunnels. This paper will explain what needs to happen for CFD to replace wind tunnels. Ultimately, we anticipate the reader will come to the same conclusion that we have drawn: both WTT and CFD will continue to play important roles in building and infrastructure design. The most pressing challenge for the design and engineering community is to understand the strengths and limitations of each tool so that they can leverage and exploit the benefits that each offers while adhering to our moral and professional obligation to hold paramount the safety, health, and welfare of the public.

CAN A WIND MODEL MIMIC A CONVECTION-DOMINATED ACCRETION FLOW MODEL\ulcorner

  • Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2001
  • In this paper we investigate the properties of advection-dominated accretion flows (ADAFs) in case that outflows carry away infalling matter with its angular momentum and energy. Positive Bernoulli number in ADAFs allow a fraction of the gas to be expelled in a form of outflows. The ADAFs are also unstable to convection. We present self-similar solutions for advection-dominated accretion flows in the presence of outflows from the accretion flows(ADIOS). The axisymmetric flow is treated in variables integrated over polar sections and the effects of outflows on the accretion flow are parameterized for possible configurations compatible with the one dimensional self-similar ADAF solution. We explicitly derive self-similar solutions of ADAFs in the presence of outflows and show that the strong outflows in the accretion flows result in a flatter density profile, which is similar to that of the convection-dominated accretion flows(CDAFs) in which convection transports the angular momentum inward and the energy outward. There two different versions of the ADAF model should show similar behaviors in X-ray spectrum to some extent. Even though the two models may show similar behaviors, they should be distinguishable due to different physical properties. We suggest that for a central object of which mass is known these two different accretion flow should have different X-ray flux value due to deficient matter in the wind model.

  • PDF

On the Length Scale and the Wall Proximity Function in the Mellor-Yamada Level 2.5 Turbulence Closure Model for Homogeneous Flows

  • Lee, Jong-Chan;Jung, Kyung-Tae
    • Journal of the korean society of oceanography
    • /
    • 제32권2호
    • /
    • pp.75-84
    • /
    • 1997
  • Relation between the length scale and the wall proximity function in the Mellor-Yamada level 2.5 turbulence closure model has been investigated through various experiments using a range of wall proximity functions. The model performance has been evaluated quantitatively by comparing with laboratory data for wind-driven flow (Baines and Knapp, 1965) and for open-channel flows without and with adverse wind action (Tsuruya, 1985). Comparison shows that a symmetric wall proximity function used by Blumberg and Mellor(1987) gives rise to current profiles with better accuracy than asymmetric wall proximity functions considered. It is noted that in modelling homogeneous flows the length scale 1= 0.31${\|}$z${\|}$(1+z/h) can be used with tolerable accuracy.

  • PDF

유동 저항에 따른 원심홴의 선정 (Selection of Centrifugal Fan for Flows with Down-Stream Resistance)

  • 김재원;장동희;안은영
    • 한국유체기계학회 논문집
    • /
    • 제9권3호
    • /
    • pp.44-48
    • /
    • 2006
  • Comprehensive experimental works are carried out for the optimal design of a centrifugal blower adopted in an indoor unit of an air-conditioner. The models for consideration are typical multi-blade turbo blower and limit loaded one, respectively. The main interest lies on the fluid dynamics performance when the blower Is installed in the practical system. The methodologies are an experimental estimations with a wind tunnel for blower performance and PIV measurement for the detail flow information. A centrifugal blower with limit loaded fan shows pronounced performances in terms of the flow rate and static pressure rise and the reason is explained by the precise measurement of the flows between blades using PIV. Consequently, it is found that the blower is proper for the flows with a resistance in down stream such as a heat exchanger.

Time-Dependent Characteristics of the Nonequilibrium Condensation in Subsonic Flows

  • Baek, Seung-Cheol;Kwon, Soon-Bum;Toshiaki Setoguchi;Kim, Heuy-Dong
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1511-1521
    • /
    • 2002
  • High-speed moist air or steam flow has long been of important subject in engineering and industrial applications. Of many complicated gas dynamics problems involved in moist air flows, the most challenging task is to understand the nonequilibrium condensation phenomenon when the moist air rapidly expands through a flow device. Many theoretical and experimental studies using supersonic wind tunnels have devoted to the understanding of the nonequilibrium condensation flow physics so far. However, the nonequilibrium condensation can be also generated in the subsonic flows induced by the unsteady expansion waves in shock tube. The major flow physics of the nonequilibrium condensation in this application may be different from those obtained in the supersonic wind tunnels. In the current study, the nonequilibrium condensation phenomenon caused by the unsteady expansion waves in a shock tube is analyzed by using the two-dimensional, unsteady, Navier-Stokes equations, which are fully coupled with a droplet growth equation. The third-order TVD MUSCL scheme is applied to solve the governing equation systems. The computational results are compared with the previous experimental data. The time-dependent behavior of nonequilibrium condensation of moist air in shock tube is investigated in details. The results show that the major characteristics of the nonequilibrium condensation phenomenon in shock tube are very different from those in the supersonic wind tunnels.

측풍영향을 고려한 고속전철 주위의 3차원 난류유동 해석 (Numerical Analysis of 3-D Turbulent Flows Around a High Speed Train Including Cross-Wind Effects)

  • 정영래;박원규;하성도
    • 한국전산유체공학회지
    • /
    • 제1권1호
    • /
    • pp.71-80
    • /
    • 1996
  • An iterative time marching procedure for solving incompressible turbulent flow has been applied to the flows around a high speed train including cross-wind effects. This procedure solves three-dimensional unsteady incompressible Reynolds-averaged Navier-Stokes equations on a non-orthogonal curvilinear coordinate system using first-order accurate schemes for the time derivatives and third/second-order accurate schemes for the spatial derivatives. Turbulent flows have been modeled by Baldwin-Lomax turbulent model. To validate present procedure, the flow around a high speed train at zero yaw angle was simulated and compared with experimental data. Generally good agreement with experiments was achieved. The flow fields around the high speed train at 9.2°, 16.7°, and 45° of yaw angle were also simulated.

  • PDF