• Title/Summary/Keyword: WALKING SPEED

Search Result 609, Processing Time 0.024 seconds

A Study on smartphone indoor navigation technology using Extended Kalman filter (확장 칼만 필터를 이용한 스마트폰 실내 위치 추적 기술 연구)

  • Do, Hyenyeol;Oh, Jongtaek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.133-138
    • /
    • 2019
  • The indoor navigation system using smart phone is a very important infrastructure technology for users' location based services in large indoor facilities. For this purpose, if the user can estimate the movement distance and direction by using the acceleration sensor and the gyro sensor built in the smartphone, the additional external environment is not necessary, which is a very useful technique. This paper deals with indoor navigation system technology that uses Pedestrian Dead Reckoning (PDR) technology and Kalman filter on a general smartphone and allows the user to trace the position while moving the smartphone in front of his chest. In particular, an extended Kalman filter was designed to estimate the direction of movement, and its performance was verified when walking at a constant speed.

Effects of Recreation Combined Exercise Program on Physical Strength for Elderly Women (레크리에이션 복합운동 프로그램이 여성 노인의 체력에 미치는 효과)

  • Han, Yoon-Soo;Choi, Jung-Hyun
    • 한국노년학
    • /
    • v.28 no.4
    • /
    • pp.941-952
    • /
    • 2008
  • The purpose of this study was to improve the physical strength through the application of the recreation combined exercise program for elderly women. The subjects of this study were consisted of 20 elderly women were 75 year ~ 88 year. The recreation combined exercise program was executed 50 minute a day, 3times a week for 8 weeks. The result was significantly improved in terms of the grip strength, sit to stand, timed up & go, one leg with eyes opened, sit and reach, 4.6meter fast walking speed. Therefore, recreation combined exercise program expect that it was helpful for the elderly women in terms of physical strength.

Relationship between Hallux Valgus Severity and 3D Ground Reaction Force in Individuals with Hallux Valgus Deformity during Gait

  • Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.3
    • /
    • pp.21-27
    • /
    • 2021
  • PURPOSE: This study examined the relationship between the severity of a hallux valgus (HV) deformity and the kinetic three-dimensional ground reaction force (GRF) through a motion analysis system with force platforms in individuals with a HV deformity during normal speed walking. METHODS: The participants were 36 adults with a HV deformity. The participants were asked to walk on a 6 m walkway with 40 infrared reflective markers attached to their pelvic and lower extremities. A camera capture system and two force platforms were used to collect kinetic data during gait. A Vicon Nexus and Visual3D motion analysis software were used to calculate the kinetic GRF data. RESULTS: This research showed that the anterior maximal force that occurred in the terminal stance phase during gait had a negative correlation with the HV angle (r = -.762, p < .01). In addition, the HV angle showed a low negative correlation with the second vertical maximal force (r = .346, p < .05) and a moderate positive correlation with the late medial maximal force (r = .641, p < .01). CONCLUSION: A more severe HV deformity results in greater abnormal translation of the plantar pressure and a significantly reduced pressure force under the first metatarsophalangeal joint.

Design and Implementation of a Mobile-based Sarcopenia Prediction and Monitoring System (모바일 기반의 '근감소증' 예측 및 모니터링 시스템 설계 및 구현)

  • Kang, Hyeonmin;Park, Chaieun;Ju, Minina;Seo, Seokkyo;Jeon, Justin Y.;Kim, Jinwoo
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.3
    • /
    • pp.510-518
    • /
    • 2022
  • This paper confirmed the technical reliability of mobile-based sarcopenia prediction and monitoring system. In implementing the developed system, we designed using only sensors built into a smartphone without a separate external device. The prediction system predicts the possibility of sarcopenia without visiting a hospital by performing the SARC-F survey, the 5-time chair stand test, and the rapid tapping test. The Monitoring system tracks and analyzes the average walking speed in daily life to quickly detect the risk of sarcopenia. Through this, it is possible to rapid detection of undiagnosed risk of undiagnosed sarcopenia and initiate appropriate medical treatment. Through prediction and monitoring system, the user may predict and manage sarcopenia, and the developed system can have a positive effect on reducing medical demand and reducing medical costs. In addition, collected data is useful for the patient-doctor communication. Furthermore, the collected data can be used for learning data of artificial intelligence, contributing to medical artificial intelligence and e-health industry.

Gait Recovery Characteristic According to the Injury Aspect of Descending Motor Pathway in a Chronic Stroke Patient: a Case Study

  • Sang Seok Yeo
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.6
    • /
    • pp.326-331
    • /
    • 2022
  • Purpose: The stroke patients have gait dysfunction due to impaired neural tracts; corticospinal tract (CST), corticoreticular pathway (CRP), and vestibulospinal tract (VST). In this study, we investigated characteristics of gait pattern according to the injury aspect of the neural track in a stroke patient. Methods: One patient and six control subjects of similar age participated. A 19-year-old male patient with spontaneous intracerebral hemorrhage on right basal ganglia, thalamus, corona radiata and cerebral cortex due to arteriovenous malformation rupture. Diffusion tensor imaging (DTI) data was acquired 21 months after the stroke. Kinematic and spatio-temporal parameters of gait were collected using a three-dimensional gait analysis system. Results: On 21 months DTI, the CST and CRP in affected hemisphere showed severe injury, in contrast, the VST in affected hemisphere showed intact integrity. Result of gait analysis, walking distance and speed were significantly decreased in a patient. The stance rate of unaffected lower limb, the swing rate of affected lower limb and the duration of double stance significantly increased compared with normal control. The knee and hip joint angle were significantly decreased in a patient. Conclusion: We found recovered independent gait ability may be associated with unimpaired VST in a patient with severe injury in CST and CRP.

A study on Data Analysis by Type of Traffic Accident for Children (어린이 교통사고 유형별 데이터 분석 연구)

  • Lee, Jeongwon;Lee, Choong Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.490-492
    • /
    • 2021
  • In order to realize a safety society in traffic accidents, Korea prepared comprehensive government-wide measures in 2017. Efforts are being made to minimize accidents while walking by children and the elderly by lowering the speed limit in urban areas from 60 km to 50 km and limiting the vehicle to 30 km in the case of child protection zones. In this study, after pre-processing each data with the status of vehicle registration and traffic accident spatial data (GIS) by designating a specific area, Danyang-gun, where the rate of child traffic accidents is increasing every year, it is intended to understand the structure of the data and find out the structural pattern of the data analytical studies were conducted.

  • PDF

Relationship between 3D Ground Reaction Force and Leg Length Discrepancy during Gait among Standing Workers

  • Kim, Yong-Wook
    • PNF and Movement
    • /
    • v.20 no.1
    • /
    • pp.59-66
    • /
    • 2022
  • Purpose: The aim of this research was to verify the relationship between three-dimensional (3D) ground reaction force (GRF) and severity of leg length discrepancy (LLD) while walking at a normal speed. It used a 3D motion analysis system with force platforms in standing workers with LLD. Methods: Subjects comprising 45 standing workers with LLD were selected. Two force platforms were used to acquire 3D GRF data based on a motion analysis system during gait. Vicon Nexus and Visual3D v6 Professional software were used to analyze kinetic GRF data. The subjects were asked to walk on a walkway with 40 infrared reflective markers attached to their lower extremities to collect 3D GRF data. Results: The results indicated the maximal force in the posterior and lateral direction of the long limb occurring in the early stance phase during gait had significant positive correlation with LLD severity (r = 0.664~0.738, p <0.01). In addition, the maximal force medial direction of the long limb occurring in the late stance phase showed a highly positive correlation with the LLD measurement (r = 0.527, p <0.01). Conclusion: Our results indicate that greater measured LLD severity results in more plantar pressure occurring in the foot area during heel contact to loading response of the stance phase and the stance push-off period during gait.

Muscle Stiffness based Intent Recognition Method for Controlling Wearable Robot (착용형 로봇을 제어하기 위한 근경도 기반의 의도 인식 방법)

  • Yuna Choi;Junsik Kim;Daehun Lee;Youngjin Choi
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.4
    • /
    • pp.496-504
    • /
    • 2023
  • This paper recognizes the motion intention of the wearer using a muscle stiffness sensor and proposes a control system for a wearable robot based on this. The proposed system recognizes the onset time of the motion using sensor data, determines the assistance mode, and provides assistive torque to the hip flexion/extension motion of the wearer through the generated reference trajectory according to the determined mode. The onset time of motion was detected using the CUSUM algorithm from the muscle stiffness sensor, and by comparing the detection results of the onset time with the EMG sensor and IMU, it verified its applicability as an input device for recognizing the intention of the wearer before motion. In addition, the stability of the proposed method was confirmed by comparing the results detected according to the walking speed of two subjects (1 male and 1 female). Based on these results, the assistance mode (gait assistance mode and muscle strengthening mode) was determined based on the detection results of onset time, and a reference trajectory was generated through cubic spline interpolation according to the determined assistance mode. And, the practicality of the proposed system was also confirmed by applying it to an actual wearable robot.

Electroacupuncture Treatment for Post-Stroke Foot Drop: A Systemic Review of Randomized Controlled Trials

  • Hye Jeong Jo;Go Eun Chae;Hyun Woo Kim;Young Jin Lee;Ahra Koh;Ji Eun Choi;So Jung Kim;Woo Young Kim
    • Journal of Acupuncture Research
    • /
    • v.41 no.2
    • /
    • pp.75-86
    • /
    • 2024
  • A review of randomized controlled trials (RCTs) using electroacupuncture (EA) to treat patients with foot drop was performed to analyze the effectiveness of EA for this condition. Relevant studies (n = 183) from 7 databases (Cochrane Library, Excerpta Medica Database, PubMed, China National Knowledge Infrastructure, Korean Studies Information Service System, Research Information Sharing Service, and Oriental Medicine Advanced Searching Integrated System) were selected based on the inclusion and exclusion criteria, and 12 RCTs met the selection criteria. In all 12 studies, EA showed significantly positive changes. In most indicators, positive changes were observed in the EA group compared with that in the control group. Significant increases were confirmed in muscle strength-related indicators such as the Fugl-Meyer motor scale, surface electromyography, active range of motion, and gait-related indicators such as the Tinetti score, maximum walking speed, and Berg balance scale. No notable adverse events were reported. EA is suggested as an effective treatment for post-stroke foot drop; however, more RCTs are required.

Step Counts and Posture Monitoring System using Insole Type Textile Capacitive Pressure Sensor for Smart Gait Analysis (깔창 형태의 전기용량성 섬유압력센서를 이용한 보행 횟수 검출 및 자세 모니터링 시스템)

  • Min, Se-Dong;Kwon, Chun-Ki
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.8
    • /
    • pp.107-114
    • /
    • 2012
  • We have developed a textile capacitive pressure sensor for smart gait analysis. The proposed system can convert sensor signal into step counts and pressure levels by different posture. To evaluate the performance of insole type textile capacitive sensor, we measured capacitance change by increment of weights from 10 kg to 100 kg with 10 kg increment using M1 class rectangular weights (four 20 kg weights and two 10 kg weights) which have ${\pm}10%$ tolerance. The result showed non-linearity characteristic of a general capacitive pressure sensor. The test was performed according to a test protocol for four different postures (sitting, standing, standing on a left leg and standing on a right leg) and different walking speeds (1 km/h and 4 km/h). Five healthy male subjects were participated in each test. As we expected, the pressure level was changed by pressure distribution according to posture. Also, developed textile pressure sensor showed higher recognition rate (average 98.06 %) than commercial pedometer at all walking speed. Therefore, the proposed step counts and posture monitoring system using conductive textile capacitive pressure sensor proved to be a reliable and useful tool for monitoring gait parameters.