• 제목/요약/키워드: Vortex turbine

검색결과 197건 처리시간 0.025초

비정상 와류격자 기법을 이용한 해상용 부유식 풍력발전기의 공력하중특성

  • 전민우;김호건;이승민;이수갑
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.62.1-62.1
    • /
    • 2011
  • The wind can be stronger and steadier further from shore, but water depth is also deeper. Then bottom-mounted towers are not feasible, and floating turbines are more competitive. There are additional motions in an offshore floating wind turbine, which results in a more complex aerodynamics operating environment for the turbine rotor. Many aerodynamic analysis methods rely on blade element momentum theory to investigate aerodynamic load, which are not valid in vortex ring state that occurs in floating wind turbine operations. So, vortex lattice method, which is more physical, was used in this analysis. Floating platform's prescribed positions were calculated in the time domain by using floating system RAO and waves that are simulated using JONSWAP spectrum. The average value of in-plane aerodynamic force increase, but the value of out-of-plane force decrease. The maximum variation aerodynamic force abruptly increases in severe sea state. Especially, as the pitch motion of the barge platform is large, this motion should be avoided to decrease the aerodynamic load variation.

  • PDF

러쉬톤 교반기의 초기 비정상 유동 특성 (Characteristics of the Starting Flow of a Rushton Turbine Mixer)

  • 박경현;김경천
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1543-1551
    • /
    • 2001
  • The characteristics of starting flow of a six-blade Rushton turbine mixer were investigated by using a cinematic Particle Image Velocimetry technique. The flows were quantified by measurements of velocity fields with a 4 ms time interval for a blade rotational speed of 100 r.p.m, so that the turbine Reynolds number(ND$^2$/ ν) was fixed to 6,960. The radial shedding of the trailing vortices starts from passing four blades after the beginning of rotation. It clearly shows that the vortex pairing phenomena caused by the interactions between trailing cortices firm consequtive blades. The average convection velocity of the radial flow is found to be 28 % of the tip velocity. The starting flow seems to arrive at a steady state after 8 revolutions in this study, which corresponds nearly one circulation through the bulk flow trajectory with the average radial convection velocity.

Assembly strategies of wind turbine towers for minimum fatigue damage

  • Nunez-Casado, Cristina;Lopez-Garcia, Oscar;de las Heras, Enrique Gomez;Cuerva-Tejero, Alvaro;Gallego-Castillo, Cristobal
    • Wind and Structures
    • /
    • 제25권6호
    • /
    • pp.569-588
    • /
    • 2017
  • The aim of this paper is to present a method to obtain the dynamic response of a wind turbine tower in time domain by means of the generation of time series and to estimate the associated fatigue damage by means of a Rainflow counting algorithm. The proposed method is based on assuming the vortex shedding is a bidimensional phenomena and on following a classical modal superposition method to obtain the structure dynamic response. Four different wind turbine tower geometric configurations have been analyzed in a range of usual wind velocities and covering extreme wind velocities. The obtained results have shown that, depending on the turbulence intensity and the mean wind velocity, there are tower geometric configurations more advantageous from the fatigue load standpoint. Consequently, the presented model can be utilized to define assembly strategies oriented to fatigue damage minimization.

Experimental study of the loads induced by a large-scale tornado simulation on a HAWT model

  • Lopez, Juan P.;Hangan, Horia;El Damatty, Ashraf
    • Wind and Structures
    • /
    • 제33권6호
    • /
    • pp.437-446
    • /
    • 2021
  • As wind turbine rotors increase, the overall loads and dynamic response become an important issue. This problem is augmented by the exposure of wind turbines to severe atmospheric events with unconventional flows such as tornadoes, which need specific designs not included in standards and codes at present. An experimental study was conducted to analyze the loads induced by a tornado-like vortex (TLV) on horizontal-axis wind turbines (HAWT). A large-scale tornado simulation developed in The Wind Engineering, Energy and Environment (WindEEE) Dome at Western University in Canada, the so-called Mode B Tornado, was employed as the TLV flow acting on a rigid wind turbine model under two rotor operational conditions (idling and parked) for five radial distances. It was observed that the overall forces and moments depend on the location and orientation of the wind turbine system with respect to the tornado vortex centre, as TLV are three-dimensional flows with velocity gradients in the radial, vertical, and tangential direction. The mean bending moment at the tower base was the most important in terms of magnitude and variation in relation to the position of the HAWT with respect to the core radius of the tornado, and it was highly dependent on the rotor Tip Speed Ratio (TSR).

Experimental study of the loads induced by a large-scale tornado simulation on a HAWT model

  • Lopez, Juan P.;Hangan, Horia;El Damatty, Ashraf
    • Wind and Structures
    • /
    • 제34권3호
    • /
    • pp.303-312
    • /
    • 2022
  • As wind turbine rotors increase, the overall loads and dynamic response become an important issue. This problem is augmented by the exposure of wind turbines to severe atmospheric events with unconventional flows such as tornadoes, which need specific designs not included in standards and codes at present. An experimental study was conducted to analyze the loads induced by a tornado-like vortex (TLV) on horizontal-axis wind turbines (HAWT). A large-scale tornado simulation developed in The Wind Engineering, Energy and Environment (WindEEE) Dome at Western University in Canada, the so-called Mode B Tornado, was employed as the TLV flow acting on a rigid wind turbine model under two rotor operational conditions (idling and parked) for five radial distances. It was observed that the overall forces and moments depend on the location and orientation of the wind turbine system with respect to the tornado vortex centre, as TLV are three-dimensional flows with velocity gradients in the radial, vertical, and tangential direction. The mean bending moment at the tower base was the most important in terms of magnitude and variation in relation to the position of the HAWT with respect to the core radius of the tornado, and it was highly dependent on the rotor Tip Speed Ratio (TSR).

Effects of load variation on a Kaplan turbine runner

  • Amiri, K.;Mulu, B.;Cervantes, M.J.;Raisee, M.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.182-193
    • /
    • 2016
  • Introduction of intermittent electricity production systems like wind and solar power to electricity market together with the deregulation of electricity markets resulted in numerous start/stops, load variations and off-design operation of water turbines. Hydraulic turbines suffer from the varying loads exerted on their stationary and rotating parts during load variations since they are not designed for such operating conditions. Investigations on part load operation of single regulated turbines, i.e., Francis and propeller, proved the formation of a rotating vortex rope (RVR) in the draft tube. The RVR induces pressure pulsations in the axial and rotating directions called plunging and rotating modes, respectively. This results in oscillating forces with two different frequencies on the runner blades, bearings and other rotating parts of the turbine. This study investigates the effect of transient operations on the pressure fluctuations exerted on the runner and mechanism of the RVR formation/mitigation. Draft tube and runner blades of the Porjus U9 model, a Kaplan turbine, were equipped with pressure sensors for this purpose. The model was run in off-cam mode during different load variations. The results showed that the transients between the best efficiency point and the high load occurs in a smooth way. However, during transitions to the part load a RVR forms in the draft tube which induces high level of fluctuations with two frequencies on the runner; plunging and rotating mode. Formation of the RVR during the load rejections coincides with sudden pressure change on the runner while its mitigation occurs in a smooth way.

Influence of the Francis Turbine location under vortex rope excitation on the Hydraulic System Stability

  • Alligne, S.;Nicolet, C.;Allenbach, P.;Kawkabani, B.;Simond, J.J.;Avellan, F.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.286-294
    • /
    • 2009
  • Hydroelectric power plants are known for their ability to cover variations of the consumption in electrical power networks. In order to follow this changing demand, hydraulic machines are subject to off-design operation. In that case, the swirling flow leaving the runner of a Francis turbine may act under given conditions as an excitation source for the whole hydraulic system. In high load operating conditions, vortex rope behaves as an internal energy source which leads to the self excitation of the system. The aim of this paper is to identify the influence of the full load excitation source location with respect to the eigenmodes shapes on the system stability. For this, a new eigenanalysis tool, based on eigenvalues and eigenvectors computation of the nonlinear set of differential equations in SIMSEN, has been developed. First the modal analysis method and linearization of the set of the nonlinear differential equations are fully described. Then, nonlinear hydro-acoustic models of hydraulic components based on electrical equivalent schemes are presented and linearized. Finally, a hydro-acoustic SIMSEN model of a simple hydraulic power plant, is used to apply the modal analysis and to show the influence of the turbine location on system stability. Through this case study, it brings out that modeling of the pipe viscoelastic damping is decisive to find out stability limits and unstable eigenfrequencies.

반와류 홀의 각도가 평판의 막냉각 효율에 미치는 영향 연구 (Effect of Anti-Vortex Hole Angle on the Flat Plate Film Cooling Effectiveness)

  • 박순상;박정신;이상훈;문영기;곽재수
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.5-10
    • /
    • 2014
  • In this paper, the experimental study was carried to investigate the effect of angle of the anti-vortex holes on the film cooling effectiveness on a flat plate. The pressure sensitive paint technique was applied to measure the film cooling effectiveness. Two anti-vortex hole angles of $0^{\circ}$ and $15^{\circ}$ with respect to the primary hole were considered, and the simple cylindrical hole case was also tested. The blowing ratio based on the cylindrical hole was 0.5 and the same flow rate was kept for all anti-vortex hole cases. Results showed that the film cooling effectiveness for the anti-vortex hole cases were much higher than that of the cylindrical case. Among the anti-vortex hole cases, $15^{\circ}$ angle anti-vortex hole case showed higher film cooling effectiveness than that by the $0^{\circ}$ angle anti-vortex hole case.

Numerical Investigation of Pressure Fluctuation Reducing in Draft Tube of Francis Turbines

  • Li, WF;Feng, JJ;Wu, H;Lu, JL;Liao, WL;Luo, XQ
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권3호
    • /
    • pp.202-208
    • /
    • 2015
  • For a prototype turbine operating under part load conditions, the turbine output is fluctuating strongly, leading to the power station incapable of connecting to the grid. The field test of the prototype turbine shows that the main reason is the resonance between the draft tube vortex frequency and the generator natural vibration frequency. In order to reduce the fluctuation of power output, different measures including the air admission, water admission and adding flow deflectors in the draft tube are put forward. CFD method is adopted to simulate the three-dimensional unsteady flow in the Francis turbine, to calculate pressure fluctuations in draft tube under three schemes and to compare with the field test result of the prototype turbine. Calculation results show that all the three measures can reduce the pressure pulsation amplitude in the draft tube. The method of water supply and adding flow deflector both can effectively change the frequency and avoid resonance, thus solving the output fluctuation problem. However, the method of air admission could not change the pressure fluctuation frequency.

고낙차 펌프-터빈에서의 축계 진동 특성 (Characteristics of the Shaft Vibration in a High Head Pump-Turbine)

  • 하현천;최성필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.166-172
    • /
    • 1998
  • This paper describes the shaft vibration phenomena measured on a pump-turbine ofa pumped storage power plant. The pump-turbine runs at a rotational speed of 450 rpm (7.5 Hz). The power output (load) of the pump-turbine was varied from 100 to 300 MW in the generating mode. It was found that the magnitude of the shaft vibration was highly dependent upon the power load. The vibration magnitude of the shaft vibration is very high in the middle load zone from 170 to 210 MW, elsewhere the vibration low. From vibration spectra, it was found that the frequency of major vibration in that load zone was 2.5 Hz which is approximately $34\%$ of the shaft rotating speed in Hz. This frequency component disappeared below and above that load zone. This subsynchronous vibration is caused by the flow induced disturbance due to spiral vortex flow downstream of the pump-turbine runner. Furthermore, it was found that shaft vibration was highly decreased due to the increase of bearing preload.

  • PDF