• Title/Summary/Keyword: Volunteers

Search Result 2,000, Processing Time 0.027 seconds

Three Dimensional Measurement of Ideal Trajectory of Pedicle Screws of Subaxial Cervical Spine Using the Algorithm Could Be Applied for Robotic Screw Insertion

  • Huh, Jisoon;Hyun, Jae Hwan;Park, Hyeong Geon;Kwak, Ho-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.376-381
    • /
    • 2019
  • Objective : To define optimal method that calculate the safe direction of cervical pedicle screw placement using computed tomography (CT) image based three dimensional (3D) cortical shell model of human cervical spine. Methods : Cortical shell model of cervical spine from C3 to C6 was made after segmentation of in vivo CT image data of 44 volunteers. Three dimensional Cartesian coordinate of all points constituting surface of whole vertebra, bilateral pedicle and posterior wall were acquired. The ideal trajectory of pedicle screw insertion was defined as viewing direction at which the inner area of pedicle become largest when we see through the biconcave tubular pedicle. The ideal trajectory of 352 pedicles (eight pedicles for each of 44 subjects) were calculated using custom made program and were changed from global coordinate to local coordinate according to the three dimensional position of posterior wall of each vertebral body. The transverse and sagittal angle of trajectory were defined as the angle between ideal trajectory line and perpendicular line of posterior wall in the horizontal and sagittal plane. The averages and standard deviations of all measurements were calculated. Results : The average transverse angles were $50.60^{\circ}{\pm}6.22^{\circ}$ at C3, $51.42^{\circ}{\pm}7.44^{\circ}$ at C4, $47.79^{\circ}{\pm}7.61^{\circ}$ at C5, and $41.24^{\circ}{\pm}7.76^{\circ}$ at C6. The transverse angle becomes more steep from C3 to C6. The mean sagittal angles were $9.72^{\circ}{\pm}6.73^{\circ}$ downward at C3, $5.09^{\circ}{\pm}6.39^{\circ}$ downward at C4, $0.08^{\circ}{\pm}6.06^{\circ}$ downward at C5, and $1.67^{\circ}{\pm}6.06^{\circ}$ upward at C6. The sagittal angle changes from caudad to cephalad from C3 to C6. Conclusion : The absolute values of transverse and sagittal angle in our study were not same but the trend of changes were similar to previous studies. Because we know 3D address of all points constituting cortical shell of cervical vertebrae. we can easily reconstruct 3D model and manage it freely using computer program. More creative measurement of morphological characteristics could be carried out than direct inspection of raw bone. Furthermore this concept of measurement could be used for the computing program of automated robotic screw insertion.

Oral Bioavailability for Sub-micron Particle Curcumin (TheracurminCR-033P) and Absorption Rate by Product Composition in Healthy Human Volunteers (서브마이크론 입자 형태 커큐민의 생체 흡수율 및 제품 조성에 따른 흡수율 동등성 연구)

  • Park, Hee Jung;Takahashi, Tsukasa;Ozawa, Hitomi
    • Food Engineering Progress
    • /
    • v.21 no.3
    • /
    • pp.273-279
    • /
    • 2017
  • Curcumin have various health-beneficial properties in numerous studies. However, its bioavailability is low due to its limited intestinal uptake and rapid metabolism. This study aimed to evaluate the pharmacokinetics of newly developed sub-micron particle curcumin with increased water dispersibility (Theracurmin(R) CR-033P). Plasma curcumin levels were measured at 0, 1, 2, 4, 8 h after Theracurmin(R) CR-033P intake using high-performance liquid chromatography. For analyzing pharmacokinetics of Theracurmin(R) CR-033P, eighteen healthy subjects were recruited and received Theracurmin(R) CR-033P at a single oral dose containing curcumin 30 mg. $C_{max}$ was 28.14 ng/ml, and the area under the curve for 8 h was estimated to be 104.36 ng/ml. Based on the area under the plasma concentration (AUC), the bioavailability of sub-micron particle curcumin was higher 22-, 35-, 28-fold than native curcumin in men, women, and all subjects, respectively. For comparing by formulation, seven healthy subjects were recruited and received two type of treatment: (1) existing dosage form 300 mg (contained curcumin 30 mg) ${\times}$ 3 capsule, (2) high dosage form 300 mg (contained curcumin 90 mg) ${\times}$ 1 capsule + placebo 300 mg ${\times}$ 2 capsule. In the cross-over study, there was no significant differences in $C_{max}$ and AUC of plasma curcumin. In conclusion, submicron particle curcumin with increased water dispersibility significantly improved its oral bioavailability and women absorbed curcumin more effectively than men. Different formulation of Theracurmin(R) CR-033P has shown equivalent to the reference in terms of pharmacokinetics.

Effects of Kinesiology tape in ankle joint of quadriceps and hamstring muscles activation during squat exercise (스쿼트 운동 시 발목 관절에 키네시오 테이프의 적용이 넙다리 네갈래근과 뒤넙다리근의 활성에 미치는 영향)

  • Park, Jae-heung;Lee, Seung-hee;Kim, So-jung;Cho, Seung-ju;Park, Hyun-hee;Lee, Yu-jin;Sim, Hye-ji;Choi, Bo-ram
    • Journal of Korean Physical Therapy Science
    • /
    • v.28 no.2
    • /
    • pp.57-64
    • /
    • 2021
  • Background: During squat exercises, Ankle joint stability during squat movement transfers forces produced by unstable supports or various loads to the leg joints and trunk, reducing the risk of injury; therefore, a reference is needed for correct ankle joint posture during squat exercises. The purpose of this study was to examine the effect of ankle joint stability on quadriceps femoris and hamstring activation during squat exercises. Design: Quasi-experiment one group pretest-posttest design. Methods: The participants in this study were 20 volunteers who performed squat exercises with and without kinesiology tape. We measured quadriceps femoris and hamstring activation using surface electromyography. The ankle joint was stabilized with kinesiology tape using the ankle balance taping (ABT) method. A paired t-test was performed to compare differences between taping conditions. Results: Vastus medialis and vastus lateralis activation were greater following squat exercises with kinesiology tape than without; however, the difference was not significant. Medial and lateral hamstring activation was not significantly different between taping conditions. Conclusion: Although it is difficult to maintain stability using kinesiology tape alone, ankle joint stability is believed to affect quadriceps femoris muscle activity, which increases the effectiveness of the squat exercise.

Invited Clinical Trials: Biocapital, Ethical Variability, and the Industrialization of Clinical Trial in Korea (초대받은 임상시험: 한국 임상시험 산업화 과정에서 생명자본(biocapital)과 윤리 가변성(ethical variability))

  • Song, Hwasun;Park, Buhm Soon
    • Journal of Science and Technology Studies
    • /
    • v.18 no.3
    • /
    • pp.1-45
    • /
    • 2018
  • South Korea has recently emerged as one of the leading countries conducting clinical trials. Seoul, for instance, is now ranked at the top of the list among the cities in the world. This paper examines the rapid growth of research involving human subjects in Korea, not just from the economic perspective (e.g., the growth of global pharmaceutical markets and the subsequent increase in the demand for clinical trials), but from the policy perspective (e.g., the government?s drive to support and promote this field as a new industry). The industrialization of clinical trials in Korea has manifested itself in the rise of international Contract Research Organizations (CRO) doing their business in Korea. They are, figuratively speaking, invited to Korea by the government. This paper intends to uncover and discuss the bioethical issues concerning research on human subjects, the issues that tend to be set aside merely as procedural ones like ??workable documents??. To this end, it investigates the practice of clinical trials by collecting hitherto unherad voices from patient-volunteers, physician-researchers, CRO employees, and government officials. This paper also explores the themes of ??ethical variability?? and ??biocapital?? in order to compare and constrast the case in Korea with those in other countries.

Intraosseous anesthesia in symptomatic irreversible pulpitis: Impact of bone thickness on perception and duration of pain

  • Nilius, Manfred;Mueller, Charlotte;Nilius, Minou Helene;Haim, Dominik;Leonhardt, Henry;Lauer, Guenter
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.6
    • /
    • pp.367-375
    • /
    • 2020
  • Background: Intraosseous anesthesia (IO) allows the anesthetic solution to be injected directly into the cancellous bone. The anesthetic solution immediately reaches the periapical region, and thus the axonal area of the nerve, where it can temporarily disable the sodium pump. The effect is felt almost without any time delay, and only a small amount of anesthetic solution is required. Methods: This study aims to investigate the efficacy of IO using the AnestoⓇ device after infiltration anesthesia (IA) and/or inferior alveolar nerve block anesthesia (IANB) failed to work in symptomatic irreversible pulpitis (hot tooth). The 33 patients included in the study were treated additionally with 1.7 ml articaine hydrochloride with 1:100,000 epinephrine hydrochloride (UltracainⓇ D-S, Sanofi-Aventis, Frankfurt, Germany) IO. Results: The electrical pulp test showed that 95.76% of the volunteers reacted positively to the combination of IANB or IA with the IO. In women, the additive IO was effective at 97.22%. In men, the IO led to pain elimination in 94.00% of cases. The duration of the IO was less than a quarter of an hour (13.03 min). The IO worked longer in women than in men (13.61 min vs. 12.33 min). Overall, more than every third tooth that needed trepanation was located in the posterior area of the mandible (36.4%). Treatment of hot teeth in this area was associated with an increased pulse rate and increased residual pain. There was a moderate correlation (Spearman-Rho [IRI] = 0.280) between the Visual Analog Scale (VAS) score and bone density, and a significant correlation (IRI = 0.612) between subjective residual pain and bone width. The IO resulted in a moderate, transient increase in the pulse rate by approximately 20 bpm. This is similar to the temporary increase in heart rate after conventional anesthesia techniques in non-preloaded patients and can be considered clinically irrelevant. Conclusion: IO with the AnestoⓇ device as an extension and deepening of local pain elimination is recommended for the treatment of hot teeth.

Comparison of pharmacokinetic characteristics of sildenafil citrate chewable tablets and film-coated tablets in healthy male subjects

  • Yoo, Hyounggyoon;Cho, Sang Min;Choi, Youn Woong;Lee, Hye Jung;Kwon, Ji-Hye;Kim, Soo-Whan;Kim, Jae Woo;Lee, SeungHwan;Hong, Jang-Hee
    • Translational and Clinical Pharmacology
    • /
    • v.25 no.3
    • /
    • pp.153-156
    • /
    • 2017
  • UI14SDF100CW is a chewable tablet of sildenafil citrate, which was developed to improve compliance through convenience of administration. The purpose of this study was to compare the pharmacokinetic (PK) properties of sildenafil citrate chewable tablets (UI14SDF100CW) and conventional sildenafil citrate film-coated tablets ($Viagra^{(R)}$, Pfizer). A randomized, open-label, single dose, two-treatment, two-period, two-way crossover study was conducted in 60 healthy male volunteers. In each period, the subjects received a single oral dose of UI14SDF100CW or $Viagra^{(R)}$ (both tablets contain 140.45 mg of sildenafil citrate, which is equivalent to 100 mg of sildenafil). Serial blood samples were collected up to 24 h post-dose for PK analysis. The plasma concentration of sildenafil was determined using a validated HPLC-MS/MS assay. PK parameters of sildenafil were calculated using non-compartmental methods. The plasma concentration-time profiles of sildenafil in both formulations were similar. For UI14SDF100CW, the $C_{max}$ and $AUC_{last}$ of sildenafil were $1068.69{\pm}458.25$ (mean${\pm}$standard deviation) mg/L and $3580.59{\pm}1680.29h{\cdot}mg/L$, and the corresponding values for $Viagra^{(R)}$ were $1146.84{\pm}501.70mg/L$ and $3406.35{\pm}1452.31h{\cdot}mg/L$, respectively. The geometric mean ratios (90% confidence intervals) of UI14SDF100CW to $Viagra^{(R)}$ for $C_{max}$ and $AUC_{last}$ were 0.933 (0.853-1.021) and 1.034 (0.969-1.108), respectively, which met the bioequivalence criteria of Korean regulatory agency. In conclusion, UI14SDF100CW and $Viagra^{(R)}$ showed similar PK properties. Therefore, UI14SDF100CW can be an alternative to sildenafil for the treatment of erectile dysfunction, providing better compliance.

A Survey and Study on Operator's Awareness for a Suggestion of Policy for Revitalization of Small Libraries in Gwangmyeong City (광명시 작은도서관 활성화 정책 제안을 위한 운영자 인식조사 연구)

  • Choi, Man-Ho;Noh, Younghee;Kim, Yoon-Jeong
    • Journal of the Korean Society for information Management
    • /
    • v.38 no.1
    • /
    • pp.1-23
    • /
    • 2021
  • Small libraries have continued to be extended since 2013 enactment of regulations requiring establishment of small libraries in multi family housing complex not less than 500 households and the 'Living SOC Project' of national government. Gwangmyeong city designated the year of 2020 as the 'year of citizen autonomy' sharing the authority with citizens and publicly announced its plan to rapidly extend the living and cultural spaces as a part of that extension. Likewise, as the social environment and the need of users are expected to change, it seems that the small libraries in Gyangmyeong City must prepare a plan for practicing a long and mid term practices in responding to that change. Thus, this Study tries to make a suggestion for a plan for the policy for revitalization of small libraries in order to handle those changing social environment and the need of users. For this, a survey and in-depth group interview were conducted for the operators of the small libraries in Gyangmyeong City. As a result of this Study, the following policies are suggested: first, improvement of support system for improving operational system, strengthening of cooperative system of public libraries, and strengthening of role of public small libraries, strengthening of public characters of private small libraties and differentiated support through evaluation based on abilities; and second, it is necessary for utilization of circulating librarians and professional volunteers, sharing of materials through mutual lending of books, associate librarians having term of office and revitalization of small library conference by regions.

Effects of Blood Flow Restriction Exercise on the Alacrity and Balanced Capacity of Female University Students in Their 20s for Health-Care Increase (헬스케어증진을 위한 하지혈류제한운동이 20대 여대생의 순발력과 균형에 미치는 영향)

  • Seo, Tae-Hwa;Kim, Eun-Ho;Jeong, Yeon-Woo
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.333-340
    • /
    • 2020
  • This study aims to examine the effects of squat exercise on the vitality and balanced capacity of female university students in their 20s with lower blood flow control. This study selected 40 volunteers from normal adult women in their twenties. Blood flow restriction used Blood Flow Restriction bands (BFR bands). The application method was to put on a blood flow restriction belt in the lower leg of the restricted blood flow area and put 120 mmHg of pressure to limit blood flow while the subject was standing comfortably. It was found that there were statistically significant differences in Height, Maximum concentric power and Take off speed between two groups(p<.05), There was statistically unimportant differences in foot scan between two groups(p>.05). This study found that to find out the changes in balance and alacrity, the experimental and control groups were divided into two groups. In conclusion, there were no significant differences in balance capability, but there were significant differences over time in net power.

Characterization of exopolysaccharide-producing lactic acid bacteria from Taiwanese ropy fermented milk and their application in low-fat fermented milk

  • Ng, Ker-Sin;Chang, Yu-Chun;Chen, Yen-Po;Lo, Ya-Hsuan;Wang, Sheng-Yao;Chen, Ming-Ju
    • Animal Bioscience
    • /
    • v.35 no.2
    • /
    • pp.281-289
    • /
    • 2022
  • Objective: The aim of this study was to characterize the exopolysaccharides (EPS)-producing lactic acid bacteria from Taiwanese ropy fermented milk (TRFM) for developing a clean label low-fat fermented milk. Methods: Potential isolates from TRFM were selected based on the Gram staining test and observation of turbid suspension in the culture broth. Random amplified polymorphic DNA-polymerase chain reaction, 16S rRNA gene sequencing, and API CHL 50 test were used for strain identification. After evaluation of EPS concentration, target strains were introduced to low-fat milk fermentation for 24 h. Fermentation characters were checked: pH value, acidity, viable count, syneresis, and viscosity. Sensory evaluation of fermented products was carried out by 30 volunteers, while the storage test was performed for 21 days at 4℃. Results: Two EPS-producing strains (APL15 and APL16) were isolated from TRFM and identified as Lactococcus (Lc.) lactis subsp. cremoris. Their EPS concentrations in glucose and lactose media were higher than other published strains of Lc. lactis subsp. cremoris. Low-fat fermented milk separately prepared with APL15 and APL16 reached pH 4.3 and acidity 0.8% with a viable count of 9 log colony-forming units/mL. The physical properties of both products were superior to the control yogurt, showing significant improvements in syneresis and viscosity (p<0.05). Our low-fat products had appropriate sensory scores in appearance and texture according to sensory evaluation. Although decreasing viable cells of strains during the 21-day storage test, low-fat fermented milk made by APL15 exhibited stable physicochemical properties, including pH value, acidity, syneresis and sufficient viable cells throughout the storage period. Conclusion: This study demonstrated that Lc. lactis subsp. cremoris APL15 isolated from TRFM had good fermentation abilities to produce low-fat fermented milk. These data indicate that EPS-producing lactic acid bacteria have great potential to act as natural food stabilizers for low-fat fermented milk.

Immobilization Effect and Abdominal Pressure of Newly-Developed Lumbosacral Spinal Orthosis during Task Performance (새롭게 개발한 요천추 보조기의 과제 수행 중 척추의 고정효과와 복부압력)

  • Jeon, Kyung Soo;Yang, Hee Seung;Jang, Soo Woong;Shin, Hee Dong;Lee, Yun kyung;Lee, Young;Lee, Seul Bin Na;Ahn, Dong Young;Sim, Woo Sob;Cho, Min;Cho, Kyu Jik;Park, Dong Beom;Park, Kwan Soo
    • Clinical Pain
    • /
    • v.19 no.2
    • /
    • pp.70-79
    • /
    • 2020
  • Objective: We evaluated the efficacy of a newly-developed spinal orthoses (V-LSO) by comparing the stabilizing effect, abdominal pressure, and comfort of 3 different semirigid LSOs (classic LSO, V-LSO, and Cybertech®) during various body movements. Method: Thirty healthy volunteers (23~47 years, 24 males, 6 females) were selected. A dual inclinometer measured the range of motion (ROM) while the participants performed flexion/extension and lateral flexion of the lumbar spine with 3 LSOs. The LSO's pressure on the abdominal surface was measured using 9 pressure sensors while lying, sitting, standing, flexion/extension, lateral flexion, axial rotation, and lifting a box. Comfort and subjective immobilization were analyzed by a questionnaire. Results: V-LSO had a statistically significant effect on flexion over Cybertech®. No significant differences were noted during extension and lateral flexion between the 3 LSOs. The abdominal pressure showed no significant differences while supine. While sitting, standing, and lifting a box, the mean abdominal pressure for V-LSO were significantly higher than those for Cybertech®. During lumbar flexion, the mean abdominal pressures for classic LSO and V-LSO were significantly higher than that of Cybertech®. For extension, lateral flexion and axial rotation, the abdominal pressure for V-LSO was significantly higher than those of classic LSO and Cybertech®. In the subjective analysis, V-LSO and Cybertech® scored best for comfort. Conclusion: The V-LSO and Cybertech® were more comfortable than the classic LSO, and hence, may have improved compliance with decreased discomfort. V-LSO may be superior to the other LSOs in restricting lumbar movement and increasing intraabdominal pressure.