• 제목/요약/키워드: Volumetric Ratio

검색결과 385건 처리시간 0.027초

다단층 부착성장 공법($A^2/O$향)에서 순환비에 따른 질소제거 (Nitrogen Removal in the Multi-stage Bed Attached Growth Process of $A^2/O$ System with Interanal Recycle Ratio)

  • 최규철;윤용수;정일현
    • 환경위생공학
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 1997
  • The process which can stabilize water quality of treatment and improve nitrogen removal rate under the condition of high organic loading was developed by charging fibrous HBC media to single sludge nitrification-denitrification process. This process was operated easier, minimized the treatment cost, and shortened the retention time. To improve T-N removal rate, a part of nitrifing liquid at aerobic zone was recycled to anoxic zone by approximate internal recycle ratio. The experimental results are as follows ; T-N removal efficiency in the organic volumetric loading 0.14-0.19 kg/COD/m$^{3}$·d was obtained asmaxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.

  • PDF

와이어로프로 횡보강된 고중량콘크리트 전단벽의 연성평가 (Ductility Evaluation of Heavyweight Concrete Shear Walls with Wire Ropes as a Lateral Reinforcement)

  • 문주현;양근혁
    • 콘크리트학회논문집
    • /
    • 제27권3호
    • /
    • pp.207-214
    • /
    • 2015
  • 이 연구에서는 중량콘크리트 전단벽의 경계요소내에서 횡보강근으로서 와이어로프의 적용가능성을 평가하였다. 와이어로프의 횡보강근의 배근간격은 60 mm에서 120 mm로 변화되었는데, 이때의 횡보강근체적지수는 0.126~0.234이다. 와이어로프는 주철근의 외부와 경계요소내 내부의 크로스타이로 적용되었다. 와이어로프로 횡보강된 5개의 중량콘크리트 전단벽은 축력하중하에서 반복횡하중의 실험이 수행되었다. 실험결과, 횡보강근체적지수가 증가함에 따라 전단벽의 연성은 현저하게 증가한 반면, 휨 내력의 변화는 미미하였다. 전단벽의 휨 내력의 실험결과는 ACI 318-11 기준의 예측값 보다 다소 높았다. 동일한 횡보강근체적지수에서 와이어로프로 횡보강된 전단벽의 변위연성비는 일반철근으로 보강된 전단벽보다 높았다. 특히, 이 실험결과로부터 고연성설계를 위한 곡률연성비 16 이상을 확보하기 위해서는 횡보강근체적지수가 0.233 이상이 요구되었다.

음식물 쓰레기와 폐활성 슬러지를 이용한 생물학적 수소생산 및 수소생산 미생물 군집분석 (Continuous Bio-hydrogen Production from Food Waste and Waste Activated Sludge)

  • 김동건;이윤지;김동임;김지성;유명진;박대원;김미선;상병인
    • KSBB Journal
    • /
    • 제20권6호
    • /
    • pp.438-442
    • /
    • 2005
  • 1. 회분식 실험결과 유기물의 함량이 높은 음식물만을 기질로 이용한 경우보다 폐활성 슬러지의 혼합비율이 $10{\sim}20%$일 때 더 높은 수소생산을 나타내었다. 또한 폐활성 슬러지의 혼합비율이 40%인 경우에는 메탄이 발생하여 생성된 수소가 소모되는 반응을 나타내었다. 2. 연속 실험의 경우 HRT를 줄여 유기물의 부하를 증가시킬 경우 수소생산량이 급격히 증가하였으며, HRT 2일까지는 미생물의 wash out 없이 안정적 수소생산을 보였다. 3. 음식물과 폐활성 슬러지를 이용한 연속 운전을 HRT와 두 기질의 비율을 달리하여 운전한 결과 2일의 HRT와 FW:WAS=80:20의 비율에서 140 mL $H_2/g$ VSS의 높은 수소생산율을 얻을 수 있었다. 4. 음식물 쓰레기와 폐활성 슬러지의 비율을 적절히 혼합할 경우, 수소생산의 상승작용을 할 수 있는 가능성을 확인하였다. 5. SEM과 FISH 분석을 통하여 반응조 내의 수소 미생물의 공간적 분포 및 형태를 관측하였으며, 음식물이나 슬러지 주변에 많은 수소생산 미생물이 관측되었다.

고강도 철근콘크리트 교각의 내진거동특성 (Characteristic Behavior of High-Strength Reinforced Concrete Bridge Column under Simulated Seismic Loading)

  • 나홍성;이경준;류효진;황선경;이진옥
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.22-27
    • /
    • 2004
  • This experimental investigation was conducted to examine the seismic performance of reinforced concrete bridge columns. The columns were subjected to a constant axial load and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research are the volumetric ratio of transverse reinforcement (ps = 0.96, 1.44 per cent) and axial load ratio (0.05, 0.1, 0.2 P/Po) and strength $(350kgf/cm^2,\;600kgf/cm^2)$. Test results show that bridge columns with 50 per cent higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behaviour. For bridge columns with axial load ratio(P/Po) less than 0.2, the ratio of Mmax over Mad, nominal moment capacity predicted by ACI 318-02 provisions, is consistently greater than 1 with approximately a 20 percent margin of safty.

  • PDF

반복 횡하중을 받는 철근콘크리트 교각의 내진성능에 관한 실험적 연구 (An Experimental Study on Seismic Performance of Reinforced Concrete Bridge Columns under Lateral Cyclic Load)

  • 이진옥;윤현도;황선경;류효진;나홍성;이경준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.161-164
    • /
    • 2003
  • This experimental investigation was conducted to examine the seismic performance of reinforced concrete bridge columns. The columns were subjected to a constant axial load and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research are the volumetric ratio of transverse reinforcement ($P_s$ =0.96, 1.44 per cent) and axial load ratio (0.05, 0.1, 0.2 P/$P_o$). Test results show that bridge columns with 50 per cent higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behaviour. For bridge columns with axial load ratio(P/$P_o$) less than 0.2, the ratio of $M_{max}$ over $M_{aci}$, nominal moment capacity predicted by ACI 318-02 provisions, is consistently greater than 1 with approximately a 20 percent margin of safty.

  • PDF

초고강도 RC 기둥의 이력특성에 관한 실험적 연구 (Hysteric Behavior of Ultra-High Strength RC Columns)

  • 김종근;안종문;한범석;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.31-34
    • /
    • 2005
  • An experimental investigation was conducted to examine the hysteric behavior of Ultra-High strength concrete columns for the requirement of ACI provision. Seven 1/3 scaled columns were fabricated to simulate an 1/2 story of actual structural members with the cross section $300\times300mm$ and the shear span ratio 4. The main variables are axial load ratio, configuration and volumetric ratio of transverse reinforcement. It has been found that the behavior of columns was affected by axial load ratio rather than the amount and the configuration of transverse reinforcement. Consequently, to secure the ductile behavior of 100MPa Ultra-High strength concrete columns, ACI provision for the requirement of transverse steel may considered axial level and the detail of transverse reinforcement.

  • PDF

PVDF 중공사막 제조 및 벤치규모 기-액 접촉기를 이용한 SO2 흡수특성 (Preparation of PVDF Hollow Fiber Membrane and Absorption of SO2 from Flue Gas Using Bench Scale Gas-Liquid Contactor)

  • 박현희;조항대;김인원;이형근
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.521-528
    • /
    • 2008
  • 중공사막 접촉기에 적절한 PVDF 중공사막을 상전이 공정에 의하여 제조하였으며, SEM 과 기체투과도에 의하여 그 특성을 분석하였다. 벤치규모 중공사막 접촉기에서 $SO_2$ 제거를 위한 흡수제는 수산화나트륨 수용액을 사용하였다. 기체는 shell side, 액체는 lumen side로 흐르는 counter-current로 실험하였으며, 흡수제의 농도, 기체의 유속, 액가스비, 유입 $SO_2$ 농도에 따른 영향을 알아보았으며, 수학적 모델링에 의해 막 물질전달계수($k_m$)를 측정하였다. 흡수제의 농도와 액기비가 증가함에 따라 기-액 계면에서 충분한 알칼리도가 제공되므로, 액체막 저항이 감소하며, 총괄물질전달 용량계수는 증가하였다. 기체유속이 증가함에 따라 기체막저항은 감소하게 되므로 총괄물질전달 용량계수는 증가하였다.

저관리 용기일체형 벽면녹화에서 황금줄사철과 송악의 초기활착에 미치는 친수성 중합체의 효용성 (Effect of Hydrophilic Polymer on Early Stages of Plant Growth of Euonymus fortunei 'Emerald and Gold' and Hedera japonica in a Vertical Greenery System for Low Maintenance)

  • 주진희;김혜란;허혜;김원태;최은영;윤용한
    • 한국환경복원기술학회지
    • /
    • 제19권3호
    • /
    • pp.1-9
    • /
    • 2016
  • The objective of this study was to exam early stages of plant growth of Euonymus fortunei 'Emerald and Gold' and Hedera japonica grown in fabric felt bag attached on vertical greenery system with the ratio of hydrophilic polymer to substrate, 0(referred as Control), 0.1, 0.2, or 0.4% (v/v), in order to effectively utilize rainfall for low maintenance. After rainfall, the increase in volumetric water content of substrate amended with the hydrophilic polymer was between 13% and 87%, compared to that in Control. During drought period, higher ratio of hydrophilic polymer to substrate slowly decreased the volumetric water content, and increased plant height, leaf length, leaf width, number of leaves, branch number, and stem diameter of both Euonymus fortunei 'Emerald and Gold' and Hedera japonica with the highest fresh and dry weights of shoots or roots under the 0.1% ratio of hydrophilic polymer.

다단 생물반응기에 의한 질소제거 (Nitrogen Removal from Wastewater by a Multi-stage Bio-reactor)

  • 최규철;정일현
    • 환경위생공학
    • /
    • 제13권1호
    • /
    • pp.91-103
    • /
    • 1998
  • Design data for COD and nitrogen removal from wastewater were collected from Pilot's Multi-stage Bio-reactor. Hyraulic conditions and pollutant loadings were varied in order to optimize the biological and operational parameters. Pilot's experimental results summarize as followings. 1. T-N removal efficiency in the organic volumetric loading 0.2 kgCOD/m$^{3}$·d was obtained as maxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.. 2. Nitrification reaction was shown as maxium in the SCOD$_{cr}$/NH$^{+}$-N ratio of 6.5 and in more ratio than this it was decreased. Denitrification rate was the maxium as 85% in more than 7.5 of SCOD$_{cr}$/NO$_{x}$-N ratio and in the ratio over this ratio it becomes constant. 3. By utilizing an applied new model of Stover-Kincannon from Monod's kinetic model, concentration of T-N in the effluent according to flow quanity in the influent was estimated as 8.74 and -67.5 respectively. The formula for estimating T-N concentration of effluent was obtained like this: N$_e$=N$_0$(1- $\frac{8.74}{(QN$_0$/A)-67.05}$)

  • PDF

3D 매트릭스 개질기를 활용한 모사 바이오가스 부분산화 및 수증기 영향 연구 (The Study of Effect of Steam on Partial Oxidation for Model Biogas using 3D Matrix Reformer)

  • 임문섭;전영남
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.772-779
    • /
    • 2011
  • New type of syngas generator based on the partial oxidation of biogas in volumetric permeable matrix reformers was suggested as an effective, adaptable and relatively simple way of syngas and hydrogen production for various low-scale applications. The use of biogas as an energy source reduces the chance of possible emission of two greenhouse gases, $CH_4$ and $CO_2$, into the atmosphere at the same time. Its nature of being a reproducible energy source makes its use even more attractive. Parametric screening studies were achieved as air ratio, biogas component ratio, input gas temperature, Steam/Carbon ratio. As the air ratio was low, the production of the hydrogen and carbon monoxide increased in the condition that 3D matrix reformer maintains the stable driving. As it was the simulation biogas in which the carbon dioxide content is high, the flammable range became narrow. And the flammable range was extended if the injected gas was preheated. The stable driving was possible in the low air ratio. The amount of hydrogen production was increased as S/C ratio increased.