• Title/Summary/Keyword: Volumetric Method

Search Result 600, Processing Time 0.028 seconds

다양한 온도에서 석탄/바이오매스의 혼합 촤-CO2 가스화 반응특성 연구 (Kinetic Study of Coal/Biomass Blended Char-CO2 Gasification Reaction at Various temperature)

  • 김정수;김상겸;조종훈;이시훈;이영우
    • Korean Chemical Engineering Research
    • /
    • 제53권6호
    • /
    • pp.746-754
    • /
    • 2015
  • 본 연구는 이온교환법을 통해 Ni촉매를 담지한 저등급 석탄(인도네시아 Eco탄)과 바이오매스(대한민국 상록수)의 혼합물로부터 제조된 촤(char)를 $700{\sim}900^{\circ}C$ 등온조건에서 온도가 반응속도에 미치는 영향에 대해 알아보았다. $Char-CO_2$ 가스화 반응은 700, 750, 800, 850, $900^{\circ}C$의 온도에서 진행하였으며, 기-고체 반응의 가스화 거동특성을 알아보기 위하여 각각 다른 가정을 갖고 있는 shrinking core model(SCM), volumetric reaction model(VRM), random pore model(RPM), modified volumetric reaction model(MVRM)을 실험결과에 적용하여 비교하였다. Arrhenius equation를 이용하여 Ni-coal/biomass와 Non-catalyst coal/biomass의 활성화에너지를 구하였고 이를 비교하였다.

고정층 반응기에서의 저등급 석탄 혼합촉매가스화 반응특성 (Low-rank Coal Char Gasification Research with Mixed Catalysts at Fixed Reactor)

  • 안승호;박지윤;진경태;이영우
    • Korean Chemical Engineering Research
    • /
    • 제55권1호
    • /
    • pp.99-106
    • /
    • 2017
  • 본 연구에서는 인도네시아 저등급 석탄인 Kideco탄을 이용하여 질소 분위기 하에 등온상태에서 촤(char)를 생성한 후 반응가스(스팀,이산화탄소)를 주입하여 합성가스를 생성하는 가스화를 진행하였다. 온도가 반응속도에 미치는 영향을 알아보기 위해 $850^{\circ}C$ 이하의 운전온도(700, 750, 800, $850^{\circ}C$)에서 반응을 진행하였다. 촉매가 미치는 영향을 알아보기 위해 알카리계 촉매인 탄산칼륨과 금속촉매인 니켈을 이용하였으며 두가지 촉매의 혼합비율(1:9, 3:7, 5:5, 7:3, 9:1)을 다르게 하여 연구를 수행하였다. 탄산칼륨은 물리적 혼합을 통해 니켈은 이온교환법을 통해 준비하였다. 기-고체 반응 특성을 알아보기 위해 열중량분석기와 가스크로마토그래피를 통해 얻은 실험결과를 shrinking core model (SCM), volumetric reaction model (VRM), random pore model (RPM) and modified volumetric reaction model (MVRM)에 적용하여 비교하였다.

Super-resolution Microscopy with Adaptive Optics for Volumetric Imaging

  • Park, Sangjun;Min, Cheol Hong;Han, Seokyoung;Choi, Eunjin;Cho, Kyung-Ok;Jang, Hyun-Jong;Kim, Moonseok
    • Current Optics and Photonics
    • /
    • 제6권6호
    • /
    • pp.550-564
    • /
    • 2022
  • Optical microscopy is a useful tool for study in the biological sciences. With an optical microscope, we can observe the micro world of life such as tissues, cells, and proteins. A fluorescent dye or a fluorescent protein provides an opportunity to mark a specific target in the crowd of biological samples, so that an image of a specific target can be observed by an optical microscope. The optical microscope, however, is constrained in resolution due to diffraction limit. Super-resolution microscopy made a breakthrough with this diffraction limit. Using a super-resolution microscope, many biomolecules are observed beyond the diffraction limit in cells. In the case of volumetric imaging, the super-resolution techniques are only applied to a limited area due to long imaging time, multiple scattering of photons, and sample-induced aberration in deep tissue. In this article, we review recent advances in super-resolution microscopy for volumetric imaging. The super-resolution techniques have been integrated with various modalities, such as a line-scan confocal microscope, a spinning disk confocal microscope, a light sheet microscope, and point spread function engineering. Super-resolution microscopy combined with adaptive optics by compensating for wave distortions is a promising method for deep tissue imaging and biomedical applications.

SR-Ivocap resin system의 물리적 특성과 체적 안정성에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES AND VOLUMETRIC STABILITY OF SR-IVOCAP RESIN SYSTEM)

  • 은성식;권혁신;정재헌
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.453-467
    • /
    • 1998
  • This study helps to clarify conflicting reports by comparing the physical properties and accuracy of complete denture processed by the pack and press technique, continuous- pressure injection technique(SR-Ivocap system) and Mark press technique. The 6 different specimens have been evaluated using the SEM, Impact test, DSC (Differential Scanning Calorimetry) and DMTA (Dynamic Mechanical Thermal Analysis). Each sample was made of SR-Ivocap resin and QC-20 resin by different processing methods. The results were as follows ; 1. As the result of the observation on the fracture surface of resin by use of SEM, sample SR-Ivocap resin cured by continuous pressure injection method showed the most homogeneous structure. This is why molecules in SR-Ivocap resin have no orientation. 2. As the result of the Impact test in order to measure the deformity, fracture energy and impact resistance of resin, the samples with QC-20 acrylic resin and SR-Ivocap resin cured by continuous pressure injection method were exellent. 3. In consequence of measuring ${\alpha}$-glass transition temperature by use of DSC on the basis of temperature change, the glass transition temperatures of sample QC-20 resin cured by pack and press method and sample SR-Ivocap resin cured by continuous pressure injection method were very similar. Thus volumetric stability could not be evaluated only by glass transition temperature. 4. In comparing volumetric stability data by DMTA, the glass transition temperature(Tg) showed $137.88^{\circ}C$ at sample QC-20 resin cured by pack and press method and $139.78^{\circ}C$ at sample SR-Ivocap resin cured by continuous pressure injection method. Therefore sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in the dimensional stability at high temperature. 5. In comparing storage modulus data by DMTA, the storage modulus of sample SR-Ivocap resin cured by continuous pressure injection method was higher than that of sample QC-20 resin cured by pack and press method. So. sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in impact strength.

  • PDF

초산(醋酸)훼닐수은(水銀)의 Polarography (Polarography of Phenyl Mercuric Acetate)

  • 강영규
    • Applied Biological Chemistry
    • /
    • 제1권
    • /
    • pp.26-33
    • /
    • 1960
  • Organic mercurial fungicides, for seed treatments and dust formulations, has been increasingly used by farmers. Evaluation of the purity of organic mercurial fungicides has been performed by precipitation method at this laboratory. There are several methods for the an alyses of organic mercuric formulation, among which are (1) Precipitation met hod, (2) Volatilization method, (3) Volumetric method, and (4) Dithizon method. These methods, however, show some deffects in specificity (differentiation of organic form) and quantitativity. Polarography applied for the estimation of phenyl mercuric acetate was found to be simple, rapid and accurate. Tile fundamental method of polarography arid accuracy of analysis are discussed statistically and a satisfactory results was obtained.

  • PDF

MRI Content-Adaptive Finite Element Mesh Generation Toolbox

  • Lee W.H.;Kim T.S.;Cho M.H.;Lee S.Y.
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권3호
    • /
    • pp.110-116
    • /
    • 2006
  • Finite element method (FEM) provides several advantages over other numerical methods such as boundary element method, since it allows truly volumetric analysis and incorporation of realistic electrical conductivity values. Finite element mesh generation is the first requirement in such in FEM to represent the volumetric domain of interest with numerous finite elements accurately. However, conventional mesh generators and approaches offered by commercial packages do not generate meshes that are content-adaptive to the contents of given images. In this paper, we present software that has been implemented to generate content-adaptive finite element meshes (cMESHes) based on the contents of MR images. The software offers various computational tools for cMESH generation from multi-slice MR images. The software named as the Content-adaptive FE Mesh Generation Toolbox runs under the commercially available technical computation software called Matlab. The major routines in the toolbox include anisotropic filtering of MR images, feature map generation, content-adaptive node generation, Delaunay tessellation, and MRI segmentation for the head conductivity modeling. The presented tools should be useful to researchers who wish to generate efficient mesh models from a set of MR images. The toolbox is available upon request made to the Functional and Metabolic Imaging Center or Bio-imaging Laboratory at Kyung Hee University in Korea.

VOB를 이용한 선형 설계 실용화에 대한 연구 (Practical Hull Form Design using VOB)

  • 김현철
    • 한국해양공학회지
    • /
    • 제30권4호
    • /
    • pp.235-242
    • /
    • 2016
  • In general, ship hull form design is carried out in two stages. In the first stage, the longitudinal variation of the sectional area curves is adapted from a similar mother ship to determine the volume distribution in ships. At this design stage, the initial design conditions of displacement, longitudinal center of buoyancy, etc. are satisfied and the global hydrodynamic properties of the structure are optimized. The second stage includes the local designing of the sectional forms. Sectional forms are related to the local pressure resistance in the fore- and aft-body shapes, cargo boundaries, interaction between the hull and propeller, etc. These relationships indicate that the hull sections need to be optimized in order to minimize the local resistance. The volumetric balanced (VOB) variation of ship hull forms has been suggested by Kim (2013) as a generalized, systematic variation method for determining the sectional area curves in hull form design. This method is characterized by form parameters and is based on an optimization technique. This paper emphasizes on an extensional function of the VOB considering a geometrical wave profile. We select a container ship and an LNG carrier to demonstrate the applicability of the proposed technique. Through analysis, we confirm that the VOB method, considering the geometrical wave profile, can be used as an efficient tool in the hull form design for ships.

황등화강암을 이용한 암석의 손상기준 결정방법 연구 (The Optimal Method to Determine Damage Threshold of Rock using Hwangdeung Granite)

  • 장보안;지훈;장현식
    • 지질공학
    • /
    • 제20권1호
    • /
    • pp.89-100
    • /
    • 2010
  • 암석의 손상상태를 평가하기위한 여러 방법들이 제안되어 있으나, 일부의 방법은 명확한 손상기준을 제시하기도 하지만 일부의 방법은 매우 모호하여 분석자의 주관에 따라 값이 달라지기도 한다. 그러므로 이 연구에서는 황등화강암을 대상으로 현재까지 제안된 모든 손상기준 결정방법을 적용하여, 각 방법의 적용성, 오차 및 최적의 손상기준결정 방법 등을 연구하였다. 또한 암석의 균열발달 및 파괴특성의 규명에 가장 중요한 손상기준인 균열개시응력과 균열손상응력을 FSR 및 장기 정하중 시험을 이용하여 검정하였다. 황등화강암의 균열닫힘응력과 균열개시응력은 각각 57.5 MPa, 77.6 MPa이며 균열체적변형률에서 측정하는 것이 가장 정확한 것으로 판단된다. 2차 균열개시응력은 90.6 MPa로 측정되었으며, 미소파괴음 계수 및 계수율이 균열개시응력의 측정에 가장 효과적인 것으로 판단된다. 균열결합응력 측정은 체적강성곡선, 미소파괴음 계수 및 미소파괴음 계수율이 가장 효과적인 방법으로 판단되며, 균열결합응력은 110.3 MPa이다. 균열손상응력은 체적강성곡선 및 미소파괴음 계수율에서 가장 명확히 측정되며, 약 127.5 MPa이다. 일축압축강도에 대한 비로서 나타낸 균열개시응력은 0.47로 FSR 값 0.46과 매우 유사하며, 균열손상응력은 0.77로 장기 정하중 시험을 통하여 측정된 장기 강도비 0.75~0.8과 거의 일치하여 균열개시응력 및 균열손상응력 값이 정확함을 검정하였다.

다채널 체적식 태양열 흡수기에서 열전달 수치해석 (Numerical Analysis of Heat Transfer in Multichannel Volumetric Solar Receivers)

  • 이현진;김종규;이상남;강용혁
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1383-1389
    • /
    • 2011
  • 본 연구는 태양열 발전에 사용하는 공기식 다채널 체적식 흡수기의 일관성 있는 열전달 해석에 초점을 두고 있다. 이를 위해 흡수 소재 물성과 채널 형상 변화의 영향을 몬테카를로 광선추적법에 기반한 광학 모델과 전도, 대류, 복사를 고려한 1 차원 열전달 모델에 동시에 반영하였다. 광학 모델 결과는 채널 반경 대비 길이의 형상비가 매우 커서 대부분의 태양 에너지는 15 mm 이내의 짧은 길이에서 흡수됨을 증명하고 있다. 복사 열손실 분류를 통해 채널의 낮은 흡수율에서는 방사 손실은 줄지만 반사손실이 증가하여 흡수기 효율이 감소하는 것을 보였다. 큰 채널 반경이나 작은 질량 유량으로 인해 흡수기 평균 온도가 상승할 때, 방사 손실과 반사 손실 모두 증가하지만 방사 손실의 영향이 더 큰 것으로 나타났다.

체적골밀도 측정법 동향: 수술부위 골밀도 분석 (Volumetric Bone Mineral Density Measurement: for Surgery Specific Bone Volumes)

  • 이연수
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.53-59
    • /
    • 2022
  • CT영상을 기반으로 한 QCT는 CT장비와 컴퓨터영상처리기술의 발전과 함께 적은 방사선 투과양으로도 체적골밀도를 측정할 수 있는 방향으로 크게 발전하고 있다. 방사선 의료영상을 대표적인 골밀도 측정법인 이중방사선흡수계수법(DXA)은 척추나 근위대퇴골과 다른 뼈와의 상관성이 떨어지는 경우가 많고질량효과에 의한 부정확성의 근본 원인을 가지고 있기 때문에 체적골밀도측정법인 단일에너지CT영상을 이용한 QCT법이 가장 보편적인 정확한 골밀도 측정법이다. 이중에너지CT의 사용은 단단한 뼈와 동시에 종양이나 연부조직의 이상을 같이 볼 수 있는 영상을 얻을 수 있게 되어 QCT 골밀도와 함께 특정연부조직이나 장기를 검사할 수 있어 그 사용이 더욱 늘어날 것으로 예상된다. 임상수술이나 추적검사가 필요한 위치에 사용자가 해부학적으로 특정한 형상체적에 대한 국부골밀도측정 방법도 병원의 임상현장에서 활용할 기술로 대두되고 있다.