• 제목/요약/키워드: Volumetric CT

검색결과 101건 처리시간 0.02초

IMPROVEMENT OF DOSE CALCULATION ACCURACY ON kV CBCT IMAGES WITH CORRECTED ELECTRON DENSITY TO CT NUMBER CURVE

  • Ahn, Beom Seok;Wu, Hong-Gyun;Yoo, Sook Hyun;Park, Jong Min
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.17-24
    • /
    • 2015
  • To improve accuracy of dose calculation on kilovoltage cone beam computed tomography (kV CBCT) images, a custom-made phantom was fabricated to acquire an accurate CT number to electron density curve by full scatter of cone beam x-ray. To evaluate the dosimetric accuracy, 9 volumetric modulated arc therapy (VMAT) plans for head and neck (HN) cancer and 9 VMAT plans for lung cancer were generated with an anthropomorphic phantom. Both CT and CBCT images of the anthropomorphic phantom were acquired and dose-volumetric parameters on the CT images with CT density curve (CTCT), CBCT images with CT density curve ($CBCT_{CT}$) and CBCT images with CBCT density curve ($CBCT_{CBCT}$) were calculated for each VMAT plan. The differences between $CT_{CT}$ vs. $CBCT_{CT}$ were similar to those between $CT_{CT}$ vs. $CBCT_{CBCT}$ for HN VMAT plans. However, the differences between $CT_{CT}$ vs. $CBCT_{CT}$ were larger than those between $CT_{CT}$ vs. $CBCT_{CBCT}$ for lung VMAT plans. Especially, the differences in $D_{98%}$ and $D_{95%}$ of lung target volume were statistically significant (4.7% vs. 0.8% with p = 0.033 for $D_{98%}$ and 4.8% vs. 0.5% with p = 0.030 for $D_{95%}$). In order to calculate dose distributions accurately on the CBCT images, CBCT density curve generated with full scatter condition should be used especially for dose calculations in the region of large inhomogeneity.

Tumor bed volumetric changes during breast irradiation for the patients with breast cancer

  • Chung, Mi Joo;Suh, Young Jin;Lee, Hyo Chun;Kang, Dae Gyu;Kim, Eun Joong;Kim, Sung Hwan;Lee, Jong Hoon
    • Radiation Oncology Journal
    • /
    • 제31권4호
    • /
    • pp.228-233
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate changes in breast tumor bed volume during whole breast irradiation (WBI). Materials and Methods: From September 2011 to November 2012, thirty patients who underwent breast-conserving surgery (BCS) followed by WBI using computed tomography (CT) simulation were enrolled. Simulation CT scans were performed before WBI (CT1) and five weeks after the breast irradiation (CT2). The tumor bed was contoured based on surgical clips, seroma, and postoperative change. We retrospectively analyzed the factors associated with tumor bed volumetric change. Results: The median tumor bed volume on CT1 and CT2 was 29.72 and 28.6 mL, respectively. The tumor bed volume increased in 9 of 30 patients (30%) and decreased in 21 of 30 patients (70%). The median percent change in tumor bed volume between initial and boost CT was -5%. Seroma status (p = 0.010) was a significant factor in tumor bed volume reduction of 5% or greater. However, patient age, body mass index, palpability, T stage, axillary lymph node dissection, and tumor location were not significant factors for tumor bed volumetric change. Conclusion: In this study, volumetric change of tumor bed cavity was frequent. Patients with seroma after BCS had a significant volume reduction of 5% or greater in tumor bed during breast irradiation. Thus, resimulation using CT is indicated for exquisite boost treatment in breast cancer patients with seroma after surgery.

Volumetric CT Texture Analysis of Intrahepatic Mass-Forming Cholangiocarcinoma for the Prediction of Postoperative Outcomes: Fully Automatic Tumor Segmentation Versus Semi-Automatic Segmentation

  • Sungeun Park;Jeong Min Lee;Junghoan Park;Jihyuk Lee;Jae Seok Bae;Jae Hyun Kim;Ijin Joo
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1797-1808
    • /
    • 2021
  • Objective: To determine whether volumetric CT texture analysis (CTTA) using fully automatic tumor segmentation can help predict recurrence-free survival (RFS) in patients with intrahepatic mass-forming cholangiocarcinomas (IMCCs) after surgical resection. Materials and Methods: This retrospective study analyzed the preoperative CT scans of 89 patients with IMCCs (64 male; 25 female; mean age, 62.1 years; range, 38-78 years) who underwent surgical resection between January 2005 and December 2016. Volumetric CTTA of IMCCs was performed in late arterial phase images using both fully automatic and semi-automatic liver tumor segmentation techniques. The time spent on segmentation and texture analysis was compared, and the first-order and second-order texture parameters and shape features were extracted. The reliability of CTTA parameters between the techniques was evaluated using intraclass correlation coefficients (ICCs). Intra- and interobserver reproducibility of volumetric CTTAs were also obtained using ICCs. Cox proportional hazard regression were used to predict RFS using CTTA parameters and clinicopathological parameters. Results: The time spent on fully automatic tumor segmentation and CTTA was significantly shorter than that for semi-automatic segmentation: mean ± standard deviation of 1 minutes 37 seconds ± 50 seconds vs. 10 minutes 48 seconds ± 13 minutes 44 seconds (p < 0.001). ICCs of the texture features between the two techniques ranged from 0.215 to 0.980. ICCs for the intraobserver and interobserver reproducibility using fully automatic segmentation were 0.601-0.997 and 0.177-0.984, respectively. Multivariable analysis identified lower first-order mean (hazard ratio [HR], 0.982; p = 0.010), larger pathologic tumor size (HR, 1.171; p < 0.001), and positive lymph node involvement (HR, 2.193; p = 0.014) as significant parameters for shorter RFS using fully automatic segmentation. Conclusion: Volumetric CTTA parameters obtained using fully automatic segmentation could be utilized as prognostic markers in patients with IMCC, with comparable reproducibility in significantly less time compared with semi-automatic segmentation.

A micro-computed tomographic study using a novel test model to assess the filling ability and volumetric changes of bioceramic root repair materials

  • Fernanda Ferrari Esteves Torres;Jader Camilo Pinto;Gabriella Oliveira Figueira;Juliane Maria Guerreiro-Tanomaru;Mario Tanomaru-Filho
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.2.1-2.8
    • /
    • 2021
  • Objectives: New premixed bioceramic root repair materials require moisture for setting. Using micro-computed tomography (micro-CT), this study evaluated the filling ability and volumetric changes of calcium silicate-based repair materials (mineral trioxide aggregate repair high-plasticity [MTA HP] and Bio-C Repair, Angelus), in comparison with a zinc oxide and eugenol-based material (intermediate restorative material [IRM]; Dentsply DeTrey). Materials and Methods: Gypsum models with cavities 3 mm deep and 1 mm in diameter were manufactured and scanned using micro-CT (SkyScan 1272. Bruker). The cavities were filled with the cements and scanned again to evaluate their filling capacity. Another scan was performed after immersing the samples in distilled water for 7 days to assess the volumetric changes of the cements. The statistical significance of differences in the data was evaluated using analysis of variance and the Tukey test with a 5% significance level. Results: Bio-C Repair had a greater filling ability than MTA HP (p < 0.05). IRM was similar to Bio-C and MTA HP (p > 0.05). MTA HP presented the largest volumetric change (p < 0.05), showing more volume loss than Bio-C and IRM, which were similar (p > 0.05). Conclusions: Bio-C Repair is a new endodontic material with excellent filling capacity and low volumetric change. The gypsum model proposed for evaluating filling ability and volumetric changes by micro-CT had appropriate and reproducible results. This model may enhance the physicochemical evaluation of premixed bioceramic materials, which need moisture for setting.

Volumetric measurement of the tongue and oral cavity with cone-beam computed tomography: A systematic review

  • Kannitha Alina, Aflah;Winny, Yohana;Fahmi, Oscandar
    • Imaging Science in Dentistry
    • /
    • 제52권4호
    • /
    • pp.333-342
    • /
    • 2022
  • Purpose: The goal of this systematic review was to compare the use of cone-beam computed tomography (CBCT) with that of computed tomography (CT) for volumetric evaluations of the tongue and oral cavity. Materials and Methods: A search for articles was conducted in accordance with the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. The PubMed, Scopus, ScienceDirect, and SAGE Journals databases were searched for articles published between 2011 and 2021. Articles were screened and assessed for eligibility. Screening involved checking for duplication, reading the title and abstract, and reading the full text. Results: The initial search retrieved 25,780 articles. Application of the eligibility criteria yielded 16 articles for qualitative analysis. Multiple uses of CBCT were identified. In several studies, researchers assessed the volumetric correlation between tongue and oral cavity volumes, as well as other parameters. Post-treatment volumetric evaluations of the oral cavity were also reported, and the reliability of CBCT was assessed. The use of CT resembled that of CBCT. Conclusion: CBCT has been used in the evaluation of tongue and oral cavity volumes to assess correlations between those volumes and with the upper airway. It has also been used for volumetric evaluation after surgical and nonsurgical procedures and to assess the relationships between tongue volume, tooth position, occlusion, and body mass index. Participants with obstructive sleep apnea and malocclusion have been evaluated, and the reliability of CBCT has been assessed. In the included studies, CT was utilized for similar purposes as CBCT, but its reliability was not assessed.

Prognostic Value of Artificial Intelligence-Driven, Computed Tomography-Based, Volumetric Assessment of the Volume and Density of Muscle in Patients With Colon Cancer

  • Minsung Kim;Sang Min Lee;Il Tae Son;Taeyong Park;Bo Young Oh
    • Korean Journal of Radiology
    • /
    • 제24권9호
    • /
    • pp.849-859
    • /
    • 2023
  • Objective: The prognostic value of the volume and density of skeletal muscles in the abdominal waist of patients with colon cancer remains unclear. This study aimed to investigate the association between the automated computed tomography (CT)-based volume and density of the muscle in the abdominal waist and survival outcomes in patients with colon cancer. Materials and Methods: We retrospectively evaluated 474 patients with colon cancer who underwent surgery with curative intent between January 2010 and October 2017. Volumetric skeletal muscle index and muscular density were measured at the abdominal waist using artificial intelligence (AI)-based volumetric segmentation of body composition on preoperative pre-contrast CT images. Patients were grouped based on their skeletal muscle index (sarcopenia vs. not) and muscular density (myosteatosis vs. not) values and combinations (normal, sarcopenia alone, myosteatosis alone, and combined sarcopenia and myosteatosis). Postsurgical disease-free survival (DFS) and overall survival (OS) were analyzed using univariable and multivariable analyses, including multivariable Cox proportional hazard regression. Results: Univariable analysis showed that DFS and OS were significantly worse for the sarcopenia group than for the non-sarcopenia group (P = 0.044 and P = 0.003, respectively, by log-rank test) and for the myosteatosis group than for the non-myosteatosis group (P < 0.001 by log-rank test for all). In the multivariable analysis, the myosteatotic muscle type was associated with worse DFS (adjusted hazard ratio [aHR], 1.89 [95% confidence interval, 1.25-2.86]; P = 0.003) and OS (aHR, 1.90 [95% confidence interval, 1.84-3.04]; P = 0.008) than the normal muscle type. The combined muscle type showed worse OS than the normal muscle type (aHR, 1.95 [95% confidence interval, 1.08-3.54]; P = 0.027). Conclusion: Preoperative volumetric sarcopenia and myosteatosis, automatically assessed from pre-contrast CT scans using AI-based software, adversely affect survival outcomes in patients with colon cancer.

입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획 (3-D Conformal Radiotherapy for CNS Using CT Simulation)

  • 추성실;조광환;이창걸
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.90-98
    • /
    • 2003
  • 목적 : 척수에 전이가 가능한 뇌종양 치료를 위한 두개척수 방사선치료를 전산화단층촬영장치(volumetric spiral CT)와 입체조준장치(CT simulator) 및 3차원 조형치료계획장치(3D conformal planning system)를 이용한 두개척수 방사선치료계획 방법을 개발하고 기하학적 검증을 통하여 유용성과 정확성을 평가한다. 방법 : 연세암센터 방사선종양학과에서 두개척수 방사선치료를 받은 환자 11명을 대상으로 전산화 단층촬영을 이용한 입체 모의치료계획과 3차원 방사선조형치료를 시행하였다. 중증의 뇌종양 환자의 두경부는 두부고정틀(thermoplastic mask, $Aquaplast^{R}$)로 고정시키고, 전신은 $Vac-Loc$ $Aquaplast^{R}$ (전성물산, 한국)으로 고정한 후 전산화단층촬영장치(Spiral CT)를 이용하여 전신체적영상(volumetric image)을 얻었다. 환자자세의 재현성 확인 및 검증을 위해 두부에 세 개의 점과 전신에 기준선 및 기준점 등을 표시하였다. 이후 입체조준장치(CT-simulator)의 가상현실영상(virtual fluoroscopy)에서 인체의 크기와 방향에 제약이 없고 치료 침대와 고정기구에 대한 시각장애를 제거함으로써 자유롭게 모의치료를 할 수 있었으며, 조사면과 선속을 결정하고 디지털화재구성사진(digitally reconstructed radiography, DRR)과 디지털화합성사진(digitally composited radiography, DCR)을 통하여 분해능이 좋은 화질의 투시 및 모의치료영상을 획득하였다. 기하학적 검증은 치료중심점 이동시 얻은 모의치료영상과 첫 치료 시에 얻은 조사면 검증 사진(port verification film) 등을 전산화단층촬영영상으로부터 재구성한 DRR 영상과 시각적, 정량적으로 비교, 분석 였다. 결론 : 입체조준장치와 3차원 방사선치료계획 장치 등을 이용하여 두개척수 방사선 치료계획을 신속하고 정확하게 원활히 수행할 수 있었다. 가상현실영상에서 대부분의 설계작업이 이루어지므로 환자의 자세고정을 요하는 시간은 전신체적 영상을 얻는 10분 이내이므로 환자의 불편을 줄일 수 있을 뿐 아니라 모의치료과정 중의 체위 변동 변수를 제거할 수 있었다. 또한 전산화단층촬영영상을 얻음으로써 중요정상조직인 안구, 척수 등을 정확하게 설정할 수 있었고, 조사면 결정과 차폐의 정확성을 증진시킬 수 있었다. 환자자세오차는 디지털화재구성사진과 치료 시마다 얻은 포트필름에서 치료중심점과 척수 사이의 거리를 측정하여 3 mm 이내의 정확성을 얻을 수 있었다. CT조준장치를 이용한 중추신경계의 방사선 입체조형치료는 가상현실모의치료계획으로 두개척수의 방사선치료를 정확하고 용이하게 실현할 수 있었다.

  • PDF

흉부 CT 검사에서 3차원 체적 영상의 정량적 분석 (Quantitative analysis of three dimensional volumetric images in Chest CT)

  • 장현철;조재환;박철수
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.255-260
    • /
    • 2011
  • 본 연구는 흉부 CT 검사 시 늑골 골절 환자를 대상으로 3차원 체적 재구성 기법의 유용성에 대해 알아보고자 하였다. 임상에서 주로 이용 하는 재구성기법인 다평면재구성(MPR), 3차원 체적 영상 기법(VRT)을 적용하여 영상데이터를 각 각 정량적 방법과 정성적 방법으로 비교 분석하였다. 재구성 영상의 분석 및 평가결과 늑골 골절 환자의 흉부 CT 검사 시 조영 전 원 자료를 이용하여 3차원 체적영상으로 재구성 하는 것이 보다 더 인공 음영을 최소화 시켰으며, 늑골 골절 판단 및 3차원 체적 영상 재구성 소요시간이 단축 됨을 알 수 있었다.

Volumetric changes in the lumpectomy cavity during whole breast irradiation after breast conserving surgery

  • Cho, Heung-Lae;Kim, Cheol-Jin
    • Radiation Oncology Journal
    • /
    • 제29권4호
    • /
    • pp.277-282
    • /
    • 2011
  • Purpose: This study was performed to evaluate the change in the lumpectomy cavity volumes before and after whole breast radiation therapy (WBRT) and to identify factors associated with the change of volume. Materials and Methods: From September 2009 to April 2010, the computed tomography (CT) simulation data from 70 patients obtained before and after WBRT was evaluated. The lumpectomy cavity volumes were contoured based on surgical clips, seroma, and postoperative changes. Significant differences in the data from pre-WBRT CT and post-WBRT CT were assessed. Multiple variables were examined for correlation with volume reduction in the lumpectomy cavity. Results: The mean and median volume reduction in the lumpectomy cavity after WBRT were 17.6 $cm^3$ and 16.1 $cm^3$, respectively with the statistical significance (p < 0.001). The volume reduction in the lumpectomy cavity was inversely correlated with time from surgery to radiation therapy (R = 0.390). The presence of seroma was significantly associated with a volumetric change in the lumpectomy cavity after WBRT (p = 0.011). Conclusion: The volume of lumpectomy cavity reduced significantly after WBRT. As the time from surgery to the start ot WBRT increased, the volume reduction in the lumpectomy cavity during WBRT decreased. A strong correlation was observed between the presence of seroma and the reduced volume. To ensure appropriate coverage and to limit normal tissue exposure during boost irradiation in patients who has seroma at the time of starting WBRT, repeating CT simulation at boost planning is suggested.

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

  • Kim, Ho Jin;Mun, Da Na;Goo, Hyun Woo;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • 제50권2호
    • /
    • pp.71-77
    • /
    • 2017
  • Background: Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: $197mL/m^2$ vs. $175mL/m^2$, p=0.008; median LV-EDVI: $94mL/m^2$ vs. $92mL/m^2$, p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.