• 제목/요약/키워드: Volumetric Analysis

검색결과 610건 처리시간 0.025초

머시닝센터의 오차보상을 통한 구면 가공형상 측정 OMM 시스템 연구 (A study of an OMM system for machined spherical form measurement using the volumetric error compensation of Machining Center)

  • 이찬호;오창진;이응석;김성청
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.838-841
    • /
    • 2000
  • To improve the accuracy of products and improve the product quality, we need to enhance the machining accuracy of the machine tools. To this point of view, measurement and inspection of finished part as well as error analysis of machine tools has been studied for last several decades. OMM(On the Machine Measurement) has been issued to alternate with CMM, pointing out disadvantages of high expenses and lots of setting time in CMM. In this paper, we study 1) the spherical surface manufacturing by volumetric error compensation of machine tool, 2) the system development of OMM without detaching work piece from a bed of machine tool after working. 3) the generation of the finished part profile by On the machine measurement. Furthermore, the output of OMM is compared with that of CMM, and verified the feasibility of the measurement system.

  • PDF

직접접촉식 액화천연가스 기화기의 특성에 관한 연구 (A Study on Characteristics of Direct Contact LNG Evaporator)

  • 한승탁;김종보
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.903-911
    • /
    • 1994
  • This study addresses the phenomena of bubbling, icing, eruption, component varieties of the evaporated natural gas, and volumetric heat transfer coefficients obtained during the operation of a proposed LNG evaporator between LNG and water in direct contact. In the present investigation, the explosive and eruption phenomena within the water column were not observed during the entire operation of the heat exchanger. Compared with the natural gas produced by conventional LNG evaporator, the analysis of the gas produced by the direct contact LNG evaporator shows that nitrogen, methane, and ethane components were reduced by 0.002~0.007mol%(4~14%), 1.6~1.92mol%(1.9~2.3%) and 0.17~1.28mol%(1.1~8.4%) respectively, while the moisture content was rather increased by 0.51~0.76mol%. The maximum volumetric heat transfer coefficient of the direct contact heat exchanger was found to be $21, 800kW/m^3\cdotK$.

반구상의 나선형 볼바측정을 통한 공작기계 오차해석의 역기구학적 접근 (A Reverse Kinematic Approach for Error Analysis of a Machine tool Using Hemispherical Helix Ball bar test)

  • 양승한;김기훈
    • 한국정밀공학회지
    • /
    • 제18권3호
    • /
    • pp.143-151
    • /
    • 2001
  • Machine tool errors have to be characterized and predicted to improve machine tool accuracy. A real-time error compensation system has been developed based on volumetric error synthesis model which is composed of machine tool errors. This paper deals with new algorithm about verification of machine tool errors. This new algorithm uses a simplified volumetric error synthesis model. This simplified model is constructed with only main components among the error components of the machine. The main error components are analyzed by ball bar test of hemispherical helix. The novel measurement method using ball bar system has many advantages which are more efficient, easier to use than conventional measurement system.

  • PDF

헬리컬 볼바 측정을 사용한 공작기계 오차해석의 역기구학적 접근 (A Reverse Kinematic Approach for Error Analysis of a Machine Tool Using Helical Ball Bar Test)

  • 김기훈;양승한
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.703-707
    • /
    • 2000
  • Machine tool errors have to be characterized and predicted to improve machine tool accuracy. A real-time error compensation system has been developed based on volumetric error synthesis model which is composed of machine tool errors. This paper deals with new algorithm about verification of machine tool errors. This new algorithm uses a simplified volumetric error synthesis model. This simplified model is constructed with only main components among the error components of the machines. This main error components are analyzed by three-dimensional helical ball bar test. By substituting result of helical ball bar test fer simplified model, we could find that obtained error components are closed to real error components.

  • PDF

A Study on the Characteristics of Volumetric Efficiency of an Axial Piston Pump considering Piston Tilting

  • Park, In-Kyu;Rhim, Yoon-Chul
    • KSTLE International Journal
    • /
    • 제10권1_2호
    • /
    • pp.37-42
    • /
    • 2009
  • This paper presents the characteristics of volumetric efficiency of an axial type piston pump considering the piston tilting. A numerical analysis is carried out in order to obtain the pressure distribution considering the fluid inertia at the notch of the valve plate. The cylinder pressure variation and the discharge flow rate are measured experimentally according to the operating conditions such as supply pressure, rotational speed, and viscosity of the working fluid by using the cam type test apparatus. Leakage is also measured considering piston tilting. The characteristics of the volumetric efficiency are analyzed with respect to various operating conditions and leakage is also analyzed according to the piston tilting angle. Results are applicable to improve the design of an axial type piston pump.

유량계 교정장치의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Flowmeter Calibrator)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

보스 벽 두께가 사출성형의 싱크마크 발생에 미치는 영향 (Effect of Boss Wall Thickness on Sink Mark in Injection Molding)

  • 김현필;김용조
    • 한국금형공학회:학술대회논문집
    • /
    • 한국금형공학회 2008년도 하계 학술대회
    • /
    • pp.103-109
    • /
    • 2008
  • The sink mark on boss parts is generated by the volumetric shrinkage that is caused by both the molding thickness and the boss wall thickness. The volumetric shrinkage is caused by packing pressure and its amount tends to decrease by increasing the packing pressure. The packing pressure can therefore increase the flow rate to a boss part and causes the depth of sink mark to increase. As the molding thickness and the boss wall thickness in the boss part can increase the part volume, these may yield bad solidifying and also extend the molding cycle. In this paper, both the injection molding test and the flow analysis were carried out to investigate the effect of sink mark that was generated in the boss wall thickness of injection molded products. The sink mark could also be caused by thickness ratio of boss part. For a given thickness ratio of boss, several molding process parameters such as packing pressure, packing time and melt temperature, affecting to generation of the sink mark were discussed

  • PDF

Stencil Buffer를 이용한 형상의 복셀화 (Hardware accelerated Voxelization using a Stencil Buffer)

  • 장동고;김광수
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2002년도 춘계공동학술대회
    • /
    • pp.266-271
    • /
    • 2002
  • We propose a hardware accelerated voxelization method for various 3D object model such as surface models, solid models, and volumetric CSG models. The algorithm utilizes the stencil buffer that is one of modern Open히 graphics hardware features. The stencil buffer is originally used to restrict drawing to certain portions of the screen. The volumetric representations of given 3D objects are constructed slice-by-slice. For each slice, the algorithm restricts the drawing areas constructed inner region of 3D objects using the stencil buffer, and generates slices of the volumetric representation for target objects. As a result, we can provide volume graphics support for various engineering applications such as multi-axis machining simulation, collision detection and finite element analysis.

  • PDF

기구볼바를 이용한 공작기계의 오차평가 시스템 개발 (Development of Computer Aided System for Error Assessoment for Multi-axis Machine Tools using the Double Ball Bar)

  • 문준희;박희재;주종남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.336-342
    • /
    • 1994
  • This paper presents an useful technique for assessing the volumetric error in multi_axis machine tools using the kinematic double ball bar and 3 dimensional spherical contouring. The developed system proposes the 3 dimensional spherical contour for the error analysis. The developed system input the measured radial data, analysing the volumetric errors such as positional, strightness, angle, and squareness errors, etc. The developed system has been tested in a practical machine tool, and showed high

  • PDF

부피법 자동장치를 이용한 LaNi5 수소화합물의 열분석 장치개발 (Thermal Analysis of LaNi5 Hydride by Volumetric Method)

  • 한정섭;김선중
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.25-31
    • /
    • 2018
  • To apply Sievert's type apparatus to thermal analysis of hydrogen absorption materials, the dehydrogenation of $LaNi_5$ system was investigated. As the initial wt% of hydrogen was increased from 0.44 to 1.24 wt%, the peak temperature of evolution rate shifted to higher temperature. However, with the initial wt% of hydrogen higher than 0.95 wt%, the peak temperature of evolution rate did not change. As the heating rate was increased, the peak temperature increased; the peak temperatures for heating rates 0.5, 1.0 and 1.5 K/min were 262.2, 264.1, and 265.9 K respectively. The Sievert's type automatic apparatus can be successively applied to the thermal analysis of $LaNi_5$ hydride.