• Title/Summary/Keyword: Volumes

Search Result 2,618, Processing Time 0.036 seconds

Effects of Solvent Extraction by Immersion on the Quality and Storage Stability of Rice (용매침지(溶媒浸漬)에 의한 탈지(脫脂)처리가 쌀의 품질(品質) 및 저장성(貯臧性)에 미치는 영향)

  • Cheigh, Hong-Sik;Kwon, Tai-Wan
    • Korean Journal of Food Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.271-275
    • /
    • 1972
  • Effects of solvent extraction by immersion on the quality and storage stability of Korean rice were studied. Proportions of lipid extracted from whole grain of rice by immersing into two volumes(v/wt) of hexane and ethanol for 72 hours at room temperature were 0.41% and 0.38% respectively. Small changes of water content and hardness of rice were observed by solvent treatment. Cooking characteristics; that is, water-uptake ratio. extended volume, total solid, and starch-iodine blue test of rice was markedly changed by ethanol treatment, while little changes were observed by hexane treatment. No considerable differences in moisture sorption isotherm of rice were observed by both solvent treatments. Changes in TBA number and stale flavor appearance of rice treated with or without solvent immersion during storage at $60^{\circ}C$ showed that rice treated with hexane had best storage stability compared to ethanol treatment, while ethanol treatment of rice had better storage stability than no treatment. Similar results were noted in changes of the flavor score of cooked rice samples which were freeze dried.

  • PDF

Wearable Computers

  • Cho, Gil-Soo;Barfield, Woodrow;Baird, Kevin
    • Fiber Technology and Industry
    • /
    • v.2 no.4
    • /
    • pp.490-508
    • /
    • 1998
  • One of the latest fields of research in the area of output devices is tactual display devices [13,31]. These tactual or haptic devices allow the user to receive haptic feedback output from a variety of sources. This allows the user to actually feel virtual objects and manipulate them by touch. This is an emerging technology and will be instrumental in enhancing the realism of wearable augmented environments for certain applications. Tactual displays have previously been used for scientific visualization in virtual environments by chemists and engineers to improve perception and understanding of force fields and of world models populated with the impenetrable. In addition to tactual displays, the use of wearable audio displays that allow sound to be spatialized are being developed. With wearable computers, designers will soon be able to pair spatialized sound to virtual representations of objects when appropriate to make the wearable computer experience even more realistic to the user. Furthermore, as the number and complexity of wearable computing applications continues to grow, there will be increasing needs for systems that are faster, lighter, and have higher resolution displays. Better networking technology will also need to be developed to allow all users of wearable computers to have high bandwidth connections for real time information gathering and collaboration. In addition to the technology advances that make users need to wear computers in everyday life, there is also the desire to have users want to wear their computers. In order to do this, wearable computing needs to be unobtrusive and socially acceptable. By making wearables smaller and lighter, or actually embedding them in clothing, users can conceal them easily and wear them comfortably. The military is currently working on the development of the Personal Information Carrier (PIC) or digital dog tag. The PIC is a small electronic storage device containing medical information about the wearer. While old military dog tags contained only 5 lines of information, the digital tags may contain volumes of multi-media information including medical history, X-rays, and cardiograms. Using hand held devices in the field, medics would be able to call this information up in real time for better treatment. A fully functional transmittable device is still years off, but this technology once developed in the military, could be adapted tp civilian users and provide ant information, medical or otherwise, in a portable, not obstructive, and fashionable way. Another future device that could increase safety and well being of its users is the nose on-a-chip developed by the Oak Ridge National Lab in Tennessee. This tiny digital silicon chip about the size of a dime, is capable of 'smelling' natural gas leaks in stoves, heaters, and other appliances. It can also detect dangerous levels of carbon monoxide. This device can also be configured to notify the fire department when a leak is detected. This nose chip should be commercially available within 2 years, and is inexpensive, requires low power, and is very sensitive. Along with gas detection capabilities, this device may someday also be configured to detect smoke and other harmful gases. By embedding this chip into workers uniforms, name tags, etc., this could be a lifesaving computational accessory. In addition to the future safety technology soon to be available as accessories are devices that are for entertainment and security. The LCI computer group is developing a Smartpen, that electronically verifies a user's signature. With the increase in credit card use and the rise in forgeries, is the need for commercial industries to constantly verify signatures. This Smartpen writes like a normal pen but uses sensors to detect the motion of the pen as the user signs their name to authenticate the signature. This computational accessory should be available in 1999, and would bring increased peace of mind to consumers and vendors alike. In the entertainment domain, Panasonic is creating the first portable hand-held DVD player. This device weight less than 3 pounds and has a screen about 6' across. The color LCD has the same 16:9 aspect ratio of a cinema screen and supports a high resolution of 280,000 pixels and stereo sound. The player can play standard DVD movies and has a hour battery life for mobile use. To summarize, in this paper we presented concepts related to the design and use of wearable computers with extensions to smart spaces. For some time, researchers in telerobotics have used computer graphics to enhance remote scenes. Recent advances in augmented reality displays make it possible to enhance the user's local environment with 'information'. As shown in this paper, there are many application areas for this technology such as medicine, manufacturing, training, and recreation. Wearable computers allow a much closer association of information with the user. By embedding sensors in the wearable to allow it to see what the user sees, hear what the user hears, sense the user's physical state, and analyze what the user is typing, an intelligent agent may be able to analyze what the user is doing and try to predict the resources he will need next or in the near future. Using this information, the agent may download files, reserve communications bandwidth, post reminders, or automatically send updates to colleagues to help facilitate the user's daily interactions. This intelligent wearable computer would be able to act as a personal assistant, who is always around, knows the user's personal preferences and tastes, and tries to streamline interactions with the rest of the world.

  • PDF

Arm Span-Height Relationship for Prediction of Spirometric Values in Korean Adult Women (우리나라 성인여성에서 정상 폐활량 예측을 위한 양팔벌린 손끝길이와 신장과의 관계)

  • Koh, Won-Jung;Ju, Young-Su;Kim, Tae-Yub;Park, Jae-Sung;Yu, Seung-Do;Choi, Kwaung-Soo;Paek, Do-Myung;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.786-794
    • /
    • 1999
  • Back ground : Arm span measurements provide a practical substitute for standing height to predict normal spirometric values in subjects unable to stand or those with a skeletal deformity such as kyphoscoliosis. The relationship between arm span and height has previously been reported as either a fixed ratio unaffected by age or as a regression equation in which the ratio varies as a function of age. The fixed ratio or regression equation is known to be specific for sex and race. Methods : We studied the relationship between standing height, arm span, and age in 381 Korean adult female subjects (ages 20 to 69 yrs) sampled in a general population. Results : The mean ratio for arm span to height is 1.004. Multiple linear analysis found arm span and age to be predictive of standing height (p=0.0001, $r^2$=0.76). We performed the analysis of the difference between the predicted height using either fixed ratio or regression equation and actual height. At the extremes of arm span and age, the ratio method either underestimated(at smaller arm span or younger age) or overestimated(at larger arm span or older age) as compared with actual height (p=0.0001). Conclusion : This results indicate that the estimated height using the fixed ratio method provides a less acceptable method of estimating height for the prediction of lung volumes in the Korean adult women when compared with the regression equations, especially at the extremes of stature or age.

  • PDF

The Correlation between HRCT Emphysema Score and Exercise Pulmonary Testing Parameters (HRCT Emphysema Scoring과 운동부하 폐기능검사 지표들 간의 상관관계)

  • Choi, Eun-Kyoung;Choi, Young-Hee;Kim, Doh-Hyung;Kim, Yong-Ho;Yoon, Se-Young;Park, Jae-Seuk;Kim, Keun-Youl;Lee, Kye-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.415-425
    • /
    • 2001
  • Background : The correlation between the high resolution computed tomography(HRCT) emphysema score and the physiologic parameters including resting and exercise pulmonary function test was investigated in 14 patients($60.6{\pm}10.3$ years) with pulmonary emphysema. Methods : The patients underwent a HRCT, a resting pulmonary function test, and incremental exercise testing(cycle ergometer, 10 W/min). Computed tomography scans were obtained on a GE highlight at 10 mm intervals using 10 mm collimation, from the apex to the base after a full inspiration. The emphysema scores were determined by a CT program 'Density mask' outlining the areas with attenuation values less than -900 HU, indicating the emphysema areas, and providing an overall percentage of lung involvement by emphysema. Results : Among the resting PFT parameters, only the diffusing capacity(r=-0.75) and $PaO_2$ (r=-0.66) correlated with the emphysema score(p<0.05). Among the exercise test parameters, the emphysema score correlated significantly with the maximum power(r=-0.74), maximum oxygen consumption(r=-0.68), anaerobic threshold(V-slope method: r=-0.69), maximal $O_2$-pulse(r=-0.73), and the physiologic dead space ratio at the maximum workload(r=-0.80)(p<0.01). Conclusion: We could find that exercise testing parameters showed a much better correlation with the HRCT emphysema score, which is known to have a good correlation with the pathologic severity than the resting PIT parameters. Therefore it is suggested that exercise testing is superior to resting PIT for estimating in the estimation of the physiologic disturbance in emphysema patients.

  • PDF

Importance of Carbon Monoxide Transfer Coefficient (KCO) Interpretation in Patients with Airflow Limitation (기류제한 환자의 일산화탄소확산능 해석에서 폐용적 보정의 의의)

  • Seo, Yong Woo;Choi, Won-Il;Lee, Jeong Eun;Park, Hun Pyo;Ko, Sung Min;Won, Kyoung Sook;Keum, Dong Yoon;Lee, Mi-Young;Jeon, Young June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.374-379
    • /
    • 2005
  • Background : The single-breath carbon monoxide diffusion capacity (DLCO) and the per unit alveolar volume (KCO; $D_LCO/VA$) gave discordant values when there was an abnormal alveolar volume (VA). However, the clinical significance of the discordant values in patients with airflow limitation has not been examined. This study investigated the $D_LCO$ and KCO changes after improving the airflow limitation. Methods : The baseline $D_LCO$ and KCO with lung volume were measured in patients with an airflow obstruction. The effective alveolar volume was measured using the single-breath $CH_4$ dilution method. The patients divided into two groups according to the baseline values: (1) increased KCO in comparison with the $D_LCO$ (high discordance) (2) decreased or not increased KCO in comparison with the $D_LCO$ (low discordance). The diffusion capacity and lung volume were measured after treatment. Results : There was no significant difference in the baseline lung volumes including the $FEV_1$ and FVC between the two groups. The $FEV_1$ and FVC were significantly increased in the high discordance group compared with the low discordance group after treating the airflow limitation. The $D_LCO$ and alveolar volume were significant higher in the high discordance group compared with the low discordance group while the TLC was not. Conclusion : The discordance between the $D_LCO$ and KCO could be translated into an airflow reversibility in patients with an airflow limitation.

The Quality Characteristics of Sponge Cake with Added Steamed Garlic Powder (증숙 마늘 분말 첨가 스폰지 케이크의 품질 특성)

  • Shin, Jung-Hye;Choi, Duck-Joo;Kwen, O-Chen
    • Korean journal of food and cookery science
    • /
    • v.23 no.5
    • /
    • pp.696-702
    • /
    • 2007
  • The effect of different steamed garlic powder concentrations on sponge cake quality were investigated by analyzing both physicochemical and sensory properties. The sponge cakes were mixed with either steamed and freeze-dried garlic powders at different ratio [0, 2, 4, 6, 8 and 10 % (w/flow w)]. The density of the prepared dough increased with increasing amounts of steamed garlic powder when the concentrations were over 4%. The heights of the sponge cakes ranged from $3.53{\pm}0.12{\sim}3.60{\pm}0.15cm$ in the $4{\sim}8%$ steamed garlic powder samples, and were significantly higher than the control. The specific loaf volume of the cake was $3.86{\pm}0.07mL/g$ the highest in the 4% steamed garlic powder samples. When the garlic powder concentration was over the 6%, the specific loaf volumes of the sponge cakes decreased with increases in garlic powder contents. The measured L- and b-values of the crust were significantly decreased with increasing garlic powder concentration while the a-value gradually increased. The L-value of the crumb increased with increasing steamed garlic powder concentration, especially at concentrations greater than 4%. The a-values were higher in the steamed garlic powder treatments than in the control. however, no significant differences were found in the concentrations over 4%. The hardness of the control was $812.42{\pm}56.69g/cm^2$, whereas it ranged from $1005.36{\pm}43.65{\sim}1522.78{\pm}204.95g/cm^2$ in the experimental groups. Hardness increased with increasing garlic powder concentration. When considering moistness, overall acceptability, and other characteristics, the optimal concentration of steamed garlic powder was found to be 4%.

Prioritizing Noxious Liquid Substances (NLS) for Preparedness Against Potential Spill Incidents in Korean Coastal Waters (해상 유해액체물질(NLS) 유출사고대비 물질군 선정에 관한 연구)

  • Kim, Young-Ryun;Choi, Jeong-Yun;Son, Min-Ho;Oh, Sangwoo;Lee, Moonjin;Lee, Sangjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.846-853
    • /
    • 2016
  • This study prioritizes Noxious Liquid Substances (NLS) transported by sea via a risk-based database containing 596 chemicals to prepare against NLS incidents. There were 158 chemicals transported in Korean waters during 2014 and 2015, which were prioritized, and then chemicals were grouped into four categories (with rankings of 0-3) based on measures for preparedness against incident. In order to establish an effective preparedness system against NLS spill incidents on a national scale, a compiling process for NLS chemicals ranked 2~3 should be carried out and managed together with an initiative for NLS chemicals ranked 0-1. Also, it is advisable to manage NLS chemicals ranked 0-1 after considering the characteristics of NLS specifically transported through a given port since the types and characteristics of NLS chemicals relevant differ depending on the port. In addition, three designated regions are suggested: 1) the southern sector of the East Sea (Ulsan and Busan); 2) the central sector of the South Sea (Gwangyang and Yeosu); and 3) the northern sector of the West Sea (Pyeongtaek, Daesan and Incheon). These regions should be considered special management sectors, with strengthened surveillance and the equipment, materials and chemicals used for pollution response management schemes prepared in advance at NLS spill incident response facilities. In the near future, the risk database should be supplemented with specific information on chronic toxicity and updated on a regular basis. Furthermore, scientific ecotoxicological data for marine organisms should be collated and expanded in a systematic way. A system allowing for the identification Hazardous and Noxious Substances (HNS) should also be established, noting the relevant volumes transported in Korean waters as soon as possible to allow for better management of HNS spill incidents at sea.

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.

Toothpick-Aided Detection of Sclerotinia homoeocarpa in the Turfgrass Leaf Canopy, Thatch, and Soil in Relation to Dollar Spot Infection Centers (이쑤시개를 이용한 잔디층, 대취층, 및 토양층에서 동전마름병 전염원의 검출)

  • Lee, Jung Han;Min, Gyu Young;Shim, Gyu Yul;Kim, Dong Soo;Sang, Hyunkyu;Jung, Geunhwa;Kwak, Youn-Sig
    • Weed & Turfgrass Science
    • /
    • v.4 no.4
    • /
    • pp.376-382
    • /
    • 2015
  • Dollar spot, caused by Sclerotinia homoeocarpa, is the major disease in cool-season turfgrasses. Understanding the distribution of this pathogen in soil and thatch is important to developing disease control strategies. In this study, toothpicks were used to detect S. homoeocarpa in the turfgrass canopy, thatch, and soil at different distances from dollar spot infection centers. The effect of penetrant and contact fungicide applications with different water volumes on distribution of S. homoeocarpa was also investigated. S. homoeocarpa was detected in 100% of samples taken from the leaf canopy, 83.3% in thatch area, and 0% in the soil from within the infection center. S. homoeocarpa was isolated in 100% of samples taken from the edge of the infection center, but was only detected in 13% of the samples taken at 1.5 cm away from the infection center edge. S. homoeocarpa was isolated at a higher frequency in the propiconazole treated plots than those treated with chlorothalonil and was not detected in leaf canopy samples when either fungicides was applied with 6.78 L of water. In conclusion, the toothpick-aided detection technique has improved our understanding of S. homoeocarpa epidemiology and could be used as a diagnostic tool to detect for fungicide resistance on golf courses.

Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame (정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과)

  • Ahn Seung Do;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoo;Nho Young Ju;Shin Kyung Hwan;Kim Kyoung Ju;Chung Won Kyun;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Purpose : To evaluate efficacy and complication of stereotactic radiosurgery using stereotactic body frame. Methods and Materials :From December 1997 to June 1999, 11 patients with primary and metastatic tumors were treated with stereotactic radiosurgery using stereotactic body frame(Precision TherapyTu). Three patients were treated with primary hepatoma and seven with metastatic tumor from liver, lung, breast, trachea and one with arteriovenous malformation on neck. We used vacuum pillow for immobilization and made skin marker on sternum and tibia area with chest marker and leg marker. Diaphragm control was used for reducing movement by respiration. CT-simulation and treatment planning were peformed. Set-up error was checked by CT-Simulator before each treatment. Dose were calculated on the 80$\~$90$\%$ isodose of isocenter dose and given consecutive 3 fractions for total dose of 30 Gy (10 Gy/fraction). Results :Median follow-up was 12 months. One patient (9$\%$) showed complete response and four Patients (36$\%$) showed partial response and others showed stable disease. Planning target volumes (PTV) ranged from 3 to 111 cc (mean 18.4 n). Set-up error was within 5 mm in all directions (X, Y, Z axis). There was no complication in all patients. Conclusion :In Primary and metastatic tumors, stereotactic body frame is very safe, accurate and effective treatment modality.

  • PDF