• 제목/요약/키워드: Volume response

검색결과 1,168건 처리시간 0.022초

공압 전달관의 동적 응답 (Dynamic Response of Pneumatic Transmission Lines)

  • 박현우;박종호;신필권;심우건
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.285-294
    • /
    • 1999
  • Transient analysis for compressible fluid flow has been performed experimentally and analytically to study the dynamic characteristics of the end volume transmission lines following a sudden pressure change a its entrance. The numerical method was developed based on the method of characteristics. The sudden pressure at its entrance was generated by rupture of diaphragm in a shock tube. The sudden pressure was used to obtain the response, as input signal for the numerical analysis. The response to the sudden pressure at the end volume was measured using a pressure transducer. The experimental result shows good agreements with the numerical result. The effects of tube length, its diameter and end volume magnitude are evaluated on the responses of the pressure and on the damping factor. It is found that the viscous damping effects on the response through the transmission pipeline becomes larger with increasing pi;eline length and decreasing diameter of the pipe and the fluid-elastic stiffness decreases with increasing the terminal volume. The numerical approach presented in this paper can be very useful in designing the instrument and control system.

  • PDF

체적부하를 갖는 유체 전달관로의 압력전파 특성 (The Propagation Characteristics of the Pressure in the Volume Loaded Fluid Transmission Line)

  • 윤선주;손병진
    • 대한기계학회논문집
    • /
    • 제18권11호
    • /
    • pp.3075-3083
    • /
    • 1994
  • The applications of the electrical transmission line theory to the pressure propagation characteristics in the volume loaded fluid transmission line with step and impulse input wave is demonstrated in this paper. The method is based on the premise that the time response is the inverse Fourier transform of frequency spectrum of the wave which spectrum is a product of frequency spectrum of input pressure wave and system transfer function. The frequency response and transient response of step and impulse input wave in the volume loaded fluid transmission line is analysed by the Laplace transform and inverse Laplace transform with FFT numerical algorithm. The numerical solution of the distributed friction model is compared with the average friction model and the infinite product model. And the result is showed that FFT method may have major advantages for the simulation of fluid circuitary.

A 3D finite element static and free vibration analysis of magneto-electro-elastic beam

  • Vinyas., M;Kattimani, S.C.
    • Coupled systems mechanics
    • /
    • 제6권4호
    • /
    • pp.465-485
    • /
    • 2017
  • In this paper, free vibration and static response of magneto-electro-elastic (MEE) beams has been investigated. To this end, a 3D finite element formulation has been derived by minimization the total potential energy and linear constitutive equation. The coupling between elastic, electric and magnetic fields can have a significant influence on the stiffness and in turn on the static behaviour of MEE beam. Further, different Barium Titanate ($BaTiO_3$) and Cobalt Ferric oxide ($CoFe_2O_4$) volume fractions results in indifferent coupled response. Therefore, through the numerical examples the influence of volume fractions and boundary conditions on the natural frequencies of MEE beam is illustrated. The study is extended to evaluate the static response of MEE beam under various forms of mechanical loading. It is seen from the numerical evaluation that the volume fractions, loading and boundary conditions have a significant effect on the structural behaviour of MEE structures. The observations made here may serve as benchmark solutions in the optimum design of MEE structures.

Prognostic implications of tumor volume response and COX-2 expression change during radiotherapy in cervical cancer patients

  • Noh, Jae Myoung;Park, Won;Huh, Seung Jae;Cho, Eun Yoon;Choi, Yoon-La;Bae, Duk Soo;Kim, Byoung-Gie
    • Radiation Oncology Journal
    • /
    • 제30권4호
    • /
    • pp.218-225
    • /
    • 2012
  • Purpose: The relationship between treatment outcomes, alteration of the expression of biological markers, and tumor volume response during radiotherapy (RT) in patients with uterine cervical cancer was analyzed. Materials and Methods: Twenty patients with cervical squamous cell carcinoma received definitive RT with (n = 17) or without (n = 3) concurrent chemotherapy. Tumor volumes were measured by three serial magnetic resonance imaging scans at pre-, mid-, and post-RT. Two serial punch biopsies were performed at pre- and mid-RT, and immunohistochemical staining for cyclooxygenase (COX)-2 and epidermal growth factor receptor was performed. The median follow-up duration was 60 months. Results: The median tumor volume response at mid-RT (V2R) was 0.396 (range, 0.136 to 0.983). At mid-RT, an interval increase in the distribution of immunoreactivity for COX-2 was observed in 8 patients, and 6 of them showed poor mid-RT tumor volume response ($V2R{\geq}0.4$). Four (20%) patients experienced disease progression after 10 to 12 months (median, 11 months). All 4 patients had poor mid-RT tumor volume response (p = 0.0867) and 3 of them had an interval increase in COX-2 expression. Overall survival (OS) and progression-free survival (PFS) decreased in patients with $V2R{\geq}0.4$ (p = 0.0291 for both). An interval increase in COX-2 expression at mid-RT was also associated with a decreased survival (p = 0.1878 and 0.1845 for OS and PFS, respectively). Conclusion: Poor tumor volume response and an interval increase in COX-2 expression at mid-RT decreased survival outcomes in patients with uterine cervical cancer.

쓰레기 종량제 실시에 따른 환경위생 문제에 관한 조사 (A study on the response of environmental sanitation problems in action of the volume based waste charge system)

  • 김영환;손종렬;문경환;류재근
    • 환경위생공학
    • /
    • 제10권1호
    • /
    • pp.35-44
    • /
    • 1995
  • The study was carried out to investigate on the response of environmental sanitation problems in action of the volume based waste charge system in Seoul The responses from the 346 persons who dwelled in Seoul was stimulatively answered, this system was considered as a successful on 70.5% of total answers, but little portion(29.4 % ) of those was unknown on the mean of this system. And we knew that this system was need to the communication and education through the press media about this one. After the action of the volume based waste system, the volume of refuse discharged in a day was decreased 30 ∼40% than before. In the problems of environmental sanitation after this system, the number of sanitary insect( cockroach etc ) and rat was decreased, also the production of orders and dust caused by refuse was decreased in comparison with those before. This results were considered that the Separate Collection should be perfectly performed. In response, the regular envelope of refuse was serious problems, the improvement for this one was demanded. The kind of difficult refuse treated was waste rubbers> electric products > furniture> foodstuffs> bottles, cans> papers, pulps etc, and the next proposal for this system should be prepared. Conclusively, the volume based waste charge system should be remarkable system In terms of resources recycling as well as wastes reduction. Above all in order to conform this system the separate collection system should be systematically performed, the next improvable proposal of the detailed methods in this system should be prepared.

  • PDF

쓰레기 종량제 실시에 따른 환경위생 문제에 관한 조사 (A Study on the Response of Environmental Sanitation Problems in Action of the Volume Based Waste Charge System.)

  • 손종렬;문경환;김영환;류재근
    • 환경위생공학
    • /
    • 제13권1호
    • /
    • pp.82-90
    • /
    • 1998
  • The study was carried out to investigate on the response of environmental sanitation problems in action of the volume based waste charge system in Seoul. The responses from the 396 persons who dwelled in Seoul was stimulatively answered, this system was considered as a successful one 69.6% of total answers, but little portion (21.2%) of those was unknown on the mean of this system. And we knew that this system was need to the communication and education through the press media about this one. After the action of the volume based waste charge system, the volume of refuse discharged in a day was decreased 30-50% than before. In the problems of environmental sanitation after this system, the number of sanitary insect(cockroach etc) and rat was decreased, also the production of order and dust caused by refuse was decreased in comparison with those before. This results were considered that the Separate Collection should be perfectly performed. In response, the regular envelope of refuge was serious problems, the improvement for this one was demanded, The kind of difficult refuse treated was waste foodstuffs> electric products> rubbers> furniture> bottles, cans>papers, pulps etc. and the next proposal for this system should be prepared. Conclusively, the volume based waste charge system should be remarkable system in terms of resources recycling as well as wastes reduction. Above all in order to conform this system the separate collection system should be systematically performed, the next improvable proposal of the detailed methods in this system should be prepared.

  • PDF

신성 고혈압 백서 심방의 심방이뇨 호르몬분비 특성 (Characteristics of Atrial Natriuretic Peptide Release in Renal Hypertensive Rats)

  • 조경우;설경환;김선희;설경미;고규영
    • The Korean Journal of Physiology
    • /
    • 제24권2호
    • /
    • pp.261-268
    • /
    • 1990
  • It has long been suggested that the cardiac atrium is a low pressure volume receptor controlling body fluid volume and blood pressure. Recently, the cardiac atrium has been found to contain a family of powerful peptides. To clarify the relationship between high blood pressure and the biologically active atrial peptides, experiments were done to define the characteristics of atrial natriuretic peptide secretion in the isolated perfused atria of renal hypertensive rats. Higher concentrations of plasma atrial natriuretic peptide and renin activity were observed in the two-kidney, one clip hypertensive rat compared to the normotensive rat. Atrial volume changes in response to pressure elevations were attenuated in hypertensive rats compared to normotensive rats. Incremental response to atrial volume changes in ANP secretion was accentuated in hypertensive rats. These date suggest that the accentuated atrial natriuretic peptide response to volume changes of hypertensive rats may be a physiological or pathphysiological adaptation to the high blood pressure and may be, at least in part, responsible for the elevated levels of plasma atrial natriuretic peptide observed in hypertensive rats.

  • PDF

고온에서 외부 가진력을 받는 회전하는 경사기능 박판 블레이드의 동적응답 해석 (Dynamic Response Analysis of Rotating Functionally Graded Thin-Walled Blades Exposed to Steady Temperature and External Excitation)

  • 오병영;나성수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.643-648
    • /
    • 2004
  • This paper is dedicated to the thermoelastic modeling and dynamic response of the rotating blades made of functionally graded ceramic-metal based materials. The blades modeled as non-uniform thin walled beams fixed at the hub with various selected values of setting angles and pre-twisted angles. In this study, the blade is rotating with a constant angular velocity and exposed to a steady temperature field as well as external excitation. Moreover, the effect of the temperature gradient through the blade thickness is considered. Material properties are graded in the thickness direction of the blade according to the volume fraction power law distribution. The numerical results highlight the effects of the volume fraction, temperature gradient, taper ratio, setting angle and pre-twisted angle on the dynamic response of bending-bending coupled beam characteristics are provided for the case of a biconvex cross section and pertinent conclusions are outlined.

  • PDF

고온에서 외부 가진력을 받는 회전하는 경사기능 박간 블레이드의 동적응답 해석 (Dynamic Response Analysis of Rotating Functionally Graded Thin-Walled Blades Exposed to Steady High Temperature and External Excitation)

  • 나성수;오병영
    • 대한기계학회논문집A
    • /
    • 제29권7호
    • /
    • pp.976-982
    • /
    • 2005
  • This paper is dedicated to the thermoelastic modeling and dynamic response of the rotating blades made of functionally graded ceramic-metal based materials. The blades are modeled as non-uniform thin walled beams fixed at the hub with various selected values of setting angles and pre-twisted angles. In this study, the blade is rotating with a constant angular velocity and exposed to a steady temperature field as well as external excitation. Moreover, the effect of the temperature gradient through the blade thickness is considered. Material properties are graded in the thickness direction of the blade according to the volume fraction power law distribution. The numerical results highlight the effects of the volume fraction, temperature gradient, taper ratio, setting angle and pre-twisted angle on the dynamic response of bending-bending coupled beam characteristics and pertinent conclusions are outlined.

BLDC 모터의 소음 저감을 위한 로터부 구조 최적설계 (An Optimal Design of the Rotor of BLDC Motors for Noise Reduction)

  • 김지훈;고강호;김민수;허승진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.972-975
    • /
    • 2004
  • In order to reduce the noise of BLDC motor, a systematic optimization procedure for rotor structure is presented. The noise index is defined as the sum of volume velocity of FE-model that are calculated at the dominant frequencies during dehydration process, which is based on the principle of radiation simple volume source. Then, the five design variables are selected to represent the shape and layout or rotor structure. This discrete design optimization problem for minimizing the noise index is solved by 3-level orthogonal array based effect analysis. Finally, the response surface method (RSM) combined optimization approach is employed for more refining the approximate optimum.

  • PDF