• Title/Summary/Keyword: Volume control

Search Result 3,864, Processing Time 0.033 seconds

Shape Optimization of Cutouts in a Laminated Composite Plate Using Volume Control (체적제어에 의한 적층 복합재 구멍의 형상 최적화)

  • Han, Seog-Young;Ma, Young-Joon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.9
    • /
    • pp.1337-1343
    • /
    • 2004
  • Shape optimization was performed to obtain a precise shape of cutouts including the internal shape of cutouts in a laminated composite plate by three dimensional modeling using solid element. Volume control of the growth-strain method was implemented and the distributed parameter chosen as Tsai-Hill fracture index for shape optimization. It makes Tsai-Hill failure index at each element uniform in laminated composites under the predetermined volume a designer requires. Shapes optimized by Tsai-Hill failure index were compared with those of the initial shapes for the various load conditions and cutouts. The following conclusions were obtained in this study; (1) It was found that growth-strain method was applied efficiently to shape optimization of three dimensional cutouts in a laminate composite, (2) The optimal shapes of the various load conditions and cutouts were obtained, (3) The maximum Tsai-Hill failure indices of the optimal shapes were remarkably reduced comparing with those of the initial shapes.

Effective Heater-Area and Droplet-Volume Adjustable Microinjectors Using a Digitally Controlled Single Heater (단일 히터의 디지털 구동을 통한 유효 히터면적 변화 및 분사 액적크기 조절이 가능한 미소유체분사기)

  • Je Chang Han;Kang Tae Goo;Cho Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.67-73
    • /
    • 2005
  • The paper presents a single-heater microfluid injector, whose ejected droplet volume is adjusted by digital current path control for a single microheater. The previous droplet volume adjustable methods have used the digital current control for multiple heaters or the analog current control for a single heater, while the present method uses the digital current control for a single microheater. Two different microinjectors, having a rectangular heater and a circular hearter, are designed and fabricated in the chip area of $7.64\;mm{\times}5.26\;mm$. The fabricated microinjectors have been tested and characterized for the number, size, shape and lifetime of the generated bubbles as well as for the volume and velocity of the ejected droplets. The input power for the rectangular heater and the circular heater has been varied in the ranges of $8.7{\sim}24.9{\mu}W\;and\;8.1{\sim}43.8{\mu}W$, respectively. The projected area of the generated bubble has been changed in the ranges of $440{\sim}l,3600{\mu}m^2\;and\;800{\sim}3,300{\mu}m^2$ for the rectangular heater and the circular heater, respectively. The microinjector with the rectangular heater ejects three discrete levels of the droplet in the volume range of $9.4{\sim}20.7pl$ with the velocity range of $0.8{\sim}1.7m/s$, while the microinjector with the circular heater achieves five discrete levels of the droplet in the volume range of $7.4{\sim}27.4pl$ with the velocity range of $0.5{\sim}2.8m/s$.

Nonlinear Analysis of Hollow RC Columns using Volume Control Method (체적제어법에 의한 철근콘크리트 중공 기둥의 비선형 해석)

  • Lim Sang-Mook;Song Ha-Won;Byun Keun Joo;Nam Sang-Hyeok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.159-162
    • /
    • 2005
  • To overcome the drawbacks of conventional load-control method and displacement-control method, the so-called volume-control method was developed by utilizing a pressure node added into a layered shell element. The pressure node has an increment of pressure as an additional degree of freedom of the shell element. In this study, the hollow RC columns are discretized with multi-layered shell elements and a modeling technique utilizing the volume-control analysis for various hollow RC column structures is introduced. The results of the nonlinear analysis using the modeling for hollow RC columns subjected to lateral reversed cyclic loading as well as lateral loading under compression are shown. Validity of the modeling technique is also verified by comparing the analysis results with experimental results and other analysis data.

  • PDF

Comparison of Effects of Chaff and Sawdust on Aerobic Composting of Food Wastes (음식물쓰레기의 호기성 퇴비화에 있어서 왕겨와 톱밥의 영향에 관한 비교 연구)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.3
    • /
    • pp.28-34
    • /
    • 2003
  • This study was performed to compare the effects of chaff and sawdust as bulking materials on temperature, pH, weight and volume reduction and salinity in aerobic composting of food wastes. Volume ratios of food wastes to chaff in reactor of Control, Ch-l, Ch-2, Ch-3 and Ch-4 were 4:0, 4:1, 4:2, 4:3 and 4:4, respectively. Volume ratios of food wastes to sawdust in reactor of Control, Sd-l, Sd-2, Sd-3 and Sd-4 were 4:0, 4:1, 4:2, 4:3 and 4:4, respectively. Reactors were operated for 24 days with 1 hour stirring by 1 rpm and 2 hours aeration per day. The lowering of the volume ratio of food wastes to chaff and sawdust resulted in the reaction at higher reaction temperature and the elongation of the high temperature reaction period. The lowering of the volume ratio of food wastes to chaff and sawdust resulted in faster pH increase. In the volume ratio of 4:3 and 4:4, pH increased faster in food-chaff mixtures than in food-sawdust mixtures. The lowering of the volume ratio of food wastes to chaff and sawdust resulted in faster steady state in the weight reduction rate and the volume reduction rate. The weight reduction rates of chaff mixtures were higher than those of sawdust mixtures, but the volume reduction rates of sawdust mixtures were more higher than those of chaff mixtures. Salinity increased as composting reaction proceeded, due to reduction in mass weight. The final salinity of Control was 2.79%, and the final range of salinities of chaff and sawdust mixtures were 2.18∼2.37% and 1.86∼2.05%, respectively.

Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones (다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서)

  • Lee Dong Woo;Yi Soyeon;Cho Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

Error and Correction Schemes of Control Volume Radiative Energy with the Discrete Ordinates Interpolation Method (제어체적 복사열정산을 위한 구분종좌표보간법의 오차 및 보정방안)

  • Cha, Ho-Jin;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.796-803
    • /
    • 2003
  • The discrete ordinates interpolation method (DOIM) has shown good accuracy and versatile applicability for the radiation $problems^{(1,2)}$. The DOIM is a nonconservative method in that the intensity and temperature are computed only at grid points without considering control volumes. However, when the DOIM is used together with a finite volume algorithm such as $SIMPLER^{(3)}$, intensities at the control surfaces need to be calculated. For this reason, a 'quadratic' and a 'decoration' schemes are proposed and examined. They are applied to two kinds of radiation problem in one-dimensional geometries. In one problem, the intensity and temperature are calculated while the radiative heat source is given, and in the other, the intensity and the radiative heat source are computed with a given temperature field. The quadratic and the decoration schemes show very successful results. The quadratic scheme gives especially accurate results so that further decoration may not be needed. It is recommended that the quadratic and the decoration schemes may be used together, or, one of them may be applied for control volume radiative energy balance.

The Effect of Treadmill Training with Elastic Bands on the Chest Expansion and Pulmonary Functions of Young Adults

  • Lim, Sang-Wan;Seo, Kyo-Chul
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.2
    • /
    • pp.301-307
    • /
    • 2011
  • The purpose of this study was an determine whether elastic band on treadmill training might effect the chest expansion and pulmonary function of the 20's men. 40 subjects with experimental group(male: 20) and control group(male: 20) was participated in experiment. During four weeks, each group participated thirty minutes for three times per week. Subjects were assessed using pre-value and post-value measurement chest length(chest length for resting, chest expansion) and pulmonary function(forced vital capacity, forced expiratory volume at one second, FEV1/FVC, peak expiratory flow, vital capacity, tidal volume, expiratory reserve volume, inspiratory reserve volume) by the CardioTouch 3000S(BIONET, USA). These findings suggest that experimental group can be used to improve chest expansion, pulmonary function than control group. In comparison of both groups, post-test was more improved in experimental group. In conclusion, experimental group helped improving function of pulmonary volume and respiratory muscle, and thus it indicates that the functions will be more improved through the continued respiratory exercise program.

Comparison of Effects of Rice Straw and Sewage Sludge Cake on Aerobic Composting of Food Wastes (음식물쓰레기의 호기성 퇴비화에 있어서 볏짚과 하수슬러지케이크가 미치는 영향에 관한 비교 연구)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.43-50
    • /
    • 2003
  • This study was performed to compare the effects of rice straw and towage sludge cake as bulking materials on temperature, pH, weight and volume reduction, porosity, C/N ratio, salinity, and conductivity in aerobic composting of food wastes. Volume ratios of food wastes to rice straw in reactor control, RS-1, RS-2, RS-3 and RS-4 were 4:0, 4:1, 4:2, 4:3 and 4:4, respectively. Weight ratios of food wastes to sewage sludge rake in reactor control, SL-1, SL-2, SL-3 and SL-4 were 4:0, 4:1, 4:2, 4:3 and 4:4, respectively. Reactors were operated for 24 days with 1 hour stirring by 1 rpm and 2 hours aeration per day. The values of pH of food waters, rice straw and sewage sludge cake were 4.39, 7.40 and 5.79, respectively. The lowering of the volume ratio of food wastes to rice straw resulted in the high reaction temperature and the fast weight and volume reduction rates. The lowering of the weight ratio of food wastes to sewage sludge cake resulted in the slow weight and volume reduction rates. C/N ratio in control was larger than that in rice straw containing reactors, and that in rice straw containing reactors was larger than that in sewage sludge cake containing reactors. Salinity and conductivity in reactors were condensed and increased by reaction days.

The Effects of Samwha-tang Extracts on Reversible Forebrain Ischemia Experimentally Induced from the Occlusion of Middle Cerebral Artery (삼화탕(三化湯)이 중간대뇌동맥 결찰로 유발된 뇌허혈에 미치는 영향)

  • Jeong, Sung-Hyun;Park, In-Sick;Shin, Gil-Cho;Lee, Won-Chul;Kim, Dong-Eun
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.127-134
    • /
    • 2001
  • The purpose of this investigation is to evaluate the effects of Samwha-tang(三化湯) Extracts on reversible forebrain ischemia experimentally induced from the occlusion of middle cerebral artery. The volume of cerebral ischemia, the volume of cerebral edema, and the change of pyramidal neuron of the CA1 area in hippocampus through light microscopy were investigated. we obtained the following results. The volume of the control group, which had ischemic damage was 21%, and the volume of the sample group, which had ischemic damage, was 16%. The ratio of the volume of the right/left hemisphere was 117.2 in the control group, and 108.8 in the sample group. Also, the light microscopy revealed that the pyramidal cells of CA1 area in hippocampus had many damages like changes into discontinuous and unsystematic forms. But, in the sample group, the cells were less damaged compared with the control group.

  • PDF

A Study on Determination of Boron Makeup Flow Rate During the Load Follow Operation (부하추종 운전시 보론 보충 수량 결정에 관한 연구)

  • Song, Yong-Mann;Lee, Un-Chul;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 1988
  • During power plant operation, the flow rate from the CVCS makeup system is estimated using the continuity equation and mass balance equation, when the primary loop boron concentration change is required due to the power transient. For this purpose, primary loop, pressurizer and VCT(volume control tank)(in CVCS) are modeled by three control volumes which contain each mass and boron concentration. Connecting pipes between primary loop, pressurizer and CVCS are also modeled by time delay. Calculation for 14-2-6-2 (power 100-50-100) load follow case (at EOL, for KNU 7) is made using these models.

  • PDF