• Title/Summary/Keyword: Volume Delay Function

Search Result 41, Processing Time 0.022 seconds

Modeling and Simulation of the Cardiovascular System Using Baroreflex Control Model of the Heart Activity (심활성도 압반사 제어 모델을 이용한 심혈관시스템 모델링 및 시뮬레이션)

  • Choi Byeong Cheol;Jeong Do Un;Shon Jung Man;Yae Su Yung;Kim Ho Jong;Lee Hyun Cheol;Kim Yun Jin;Jung Dong keun;Yi Sang Hun;Jeon Gye Rok
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.565-573
    • /
    • 2004
  • In this paper, we proposed a heart activity control model for simulation of the aortic sinus baroreceptor, which was the most representative baroreceptor sensing the variance of pressure in the cardiovascular system. And then, the heart activity control model composed electric circuit model of the cardiovascular system with baroreflex control and time delay sub-model to observe the effect of time delay in heart period and stroke volume under the regulation of baroreflex in the aortic sinus. The mechanism of time delay in the heart activity baroreflex control model is as follows. A control function is conduct sensing pressure information in the aortic sinus baroreceptor to transmit the efferent nerve through central nervous system. As simulation results of the proposed model, we observed three patterns of the cardiovascular system variability by the time delay. First of all, if the time delay over 2.5 second, aortic pressure and stroke volume and heart rate was observed non-periodically and irregularly. However, if the time delay from 0.1 second to 0.25 second, the regular oscillation was observed. And then, if time delay under 0.1 second, then heart rate and aortic pressure-heart rate trajectory were maintained in stable state.

Development of Travel Time Functions Considering Intersection Delay (교차로 지체를 고려한 통행시간함수 개발)

  • Oh, Sang-Jin;Park, Sang-Hyuk;Park, Byung-Ho
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.4
    • /
    • pp.63-76
    • /
    • 2008
  • The goals of this study are to develop travel time functions based on intersection delay and to analyze the applicability of the functions to traffic assignment models. The study begins with the premise that the existing assignment models can not effectively account for intersection delay time. In pursuing the goals, this study gives particular attention to dividing the link travel time into link moving time and stopped time at node, making the models based on such variables as the travel speed, volume, geometry, and signal data of signalized intersections in Cheongju, and analyzing the applicability of these models to traffic assignment. There are several major findings. First, the study presents the revised percentage of lanes (considering type of intersection) instead of g/C for calculating intersection delay, which is analyzed to be significant in the paired t-test. Second, the assigned results of applying these models to the Cheongju network in EMME/2 are compared with the data observed from a test car survey in Cheongju. The analyses show that the BPR models do not consider the intersection delay, but the modified uniform delay model and modified Webster model are comparatively well fitted to the observed data. Finally, the assigned results of applying these models are statistically compared with the test car survey data in assigned volume, travel time, and average speed. The results show that the estimates from the divided travel time model are better fitted to observed data than those from the BPR model.

Study on the Influence of Mixing Effect to the Measurement of Particle Size Distribution using DMA and CPC (혼합효과가 DMA와 CPC를 이용한 입자분포 측정에 미치는 영향에 관한 연구)

  • Lee, Youn-Soo;Ahn, Kang-Ho;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.326-333
    • /
    • 2003
  • In the measurement using DMA and CPC in series, there is some time delay for particles classified in DMA to detect in CPC. During this time, the DMA time-response changes due to the velocity profile of sampling tube and the diffusion of particles in the volume that exists between the DMA exit and the detector of ultra-fine CPC. This is called mixing effect. In the accelerated measurement methods like the TSI -SMPS, the size distribution is obtained from the correlation between the time-varying electrical potential of the DMA and the corresponding particle concentrations sampled in DMA. If the DMA time -response changes during this delay time, this can cause the error of a size distribution measured by this accelerated technique. The kernel function considering this mixing effect using the residence time distribution is proposed by Russell et al. In this study, we obtained a size distribution using this kernel to compare to the result obtained by the commercial accelerated measurement system, TSI -SMPS for verification and considered the errors that result from the mixing effect with the geometric mean diameters of originally sampled particles, using virtually calculated responses obtained with this kernel as input data.

An Efficient Data Processing Method to Improve the Geostationary Ocean Color Imager (GOCI) Data Service (천리안 해양관측위성의 배포서비스 향상을 위한 자료 처리 효율화 방안 연구)

  • Yang, Hyun;Oh, Eunsong;Han, Tai-Hyun;Han, Hee-Jeong;Choi, Jong-Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • We proposed and verified the methods to maintain data qualities as well as to reduce data volume for the Geostationary Ocean Color Imager (GOCI), the world's first ocean color sensor operated in geostationary orbit. For the GOCI level-2 data, 92.9% of data volume could be saved by only the data compression. For the GOCI level-1 data, however, just 20.7% of data volume could be saved by the data compression therefore another approach was required. First, we found the optimized number of bits per a pixel for the GOCI level-1 data from an idea that the quantization bit for the GOCI (i.e. 12 bit) was less than the number of bits per a pixel for the GOCI level-1 data (i.e. 32 bit). Experiments were conducted using the $R^2$ and the Modulation Transfer Function (MTF). It was quantitatively revealed that the data qualities were maintained although the number of bits per a pixel was reduced to 14. Also, we performed network simulations using the Network Simulator 2 (Ns2). The result showed that 57.7% of the end-toend delay for a GOCI level-1 data was saved when the number of bits per a pixel was reduced to 14 and 92.5% of the end-to-end delay for a GOCI level-2 data was saved when 92.9% of the data size was reduced due to the compression.

A New adminstration of International Commercial Arbitration System and the Claim Under WTO (WTO시대의 국제상사중재제도와 클레임관리의 새 방향)

  • Jeong, Gi-In
    • Journal of Arbitration Studies
    • /
    • v.8 no.1
    • /
    • pp.3-33
    • /
    • 1998
  • Since the Start of WTO in 1995, world trade volume was substantially increased as much as over $250 billion by lifting the trade barriors This effect brought new problem of increasing disputes. Significantly an ever increasing atention is paid to the Question of means and procedures of settling such disputes by arbtration. The problem of arbitration has indeed become most popular with all those who take interest in legal aspects of international cooperation in various spheres. In practice arbitration seems to renovate its function to take over new disputes arising from electronic transaction such as internet trade. Looking at the actual use of arbitration, its merits than litigation should cover new aspect concerning new kind of claims caused by new type of transaction. The efficient procedure for dispute will help every country save loss of profit by the delay of settlment. This thesis aims to facilitate the appearence of more efficient arbitration procedure for dispute settlment system.

  • PDF

Estimation of Probability Density Functions of Damage Parameter for Valve Leakage Detection in Reciprocating Pump Used in Nuclear Power Plants

  • Lee, Jong Kyeom;Kim, Tae Yun;Kim, Hyun Su;Chai, Jang-Bom;Lee, Jin Woo
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1280-1290
    • /
    • 2016
  • This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.

A Study on Traffic analysis for System Optimization of CDMA base station and repeaters (CDMA 기지국과 중계기의 시스템 최적화를 위한 Traffic 분석 기법)

  • Jo, Ung;Chin, Yong-Ohk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4C
    • /
    • pp.333-341
    • /
    • 2002
  • This article is written to make a foundation for effective radio network engineering by enabling the accurate traffic assumption between Base Station (BTS : Base Station Transceiver Subsystem) md Repeater through the scientific and systematic analysis of mobile traffic dealt within CDMA Base Station. Among these, Repeater, having direct physical connection with BTS, simply does the remote relay function but the volume of the traffic flowed into the repeater is not accountable. The total BTS traffic is the sum of traffic dealt by the BTS and multiple Repeaters. In this article, we tried traffic analysis of this kind by adopting RTD (Round Trip Delay) which is specially designed to measure distribution of the distance between the Base Station and the Mobile station by differentiating the traffic dealt by BTS from traffic dealt by Repeaters. The fact that the connection between mobile station and BTS via Repeater (which is located remotely) yields far more delay than the direct connection between mobile station and BTS is the clue of this article. Based on this fact, Time Delay equipment was put at the receiving side of the Repeater to add certain amount of delay to the traffic to BTS and the result showed that the 99.78% of the traffic can be identified.

Calibration of a Network Link Travel Cost Function with the Harmony Search Algorithm (화음탐색법을 이용한 교통망 링크 통행비용함수 정산기법 개발)

  • Kim, Hyun Myung;Hwang, Yong Hwan;Yang, In Chul
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.5
    • /
    • pp.71-82
    • /
    • 2012
  • Some previous studies adopted a method statistically based on the observed traffic volumes and travel times to estimate the parameters. Others tried to find an optimal set of parameters to minimize the gap between the observed and estimated traffic volumes using, for instance, a combined optimization model with a traffic assignment model. The latter is frequently used in a large-scale network that has a capability to find a set of optimal parameter values, but its appropriateness has never been demonstrated. Thus, we developed a methodology to estimate a set of parameter values of BPR(Bureau of Public Road) function using Harmony Search (HS) method. HS was developed in early 2000, and is a global search method proven to be superior to other global search methods (e.g. Genetic Algorithm or Tabu search). However, it has rarely been adopted in transportation research arena yet. The HS based transportation network calibration algorithm developed in this study is tested using a grid network, and its outcomes are compared to those from incremental method (Incre) and Golden Section (GS) method. It is found that the HS algorithm outperforms Incre and GS for copying the given observed link traffic counts, and it is also pointed out that the popular optimal network calibration techniques based on an objective function of traffic volume replication are lacking the capability to find appropriate free flow travel speed and ${\alpha}$ value.

Cardiac MRI (심장 자기공명영상)

  • Lee, Jong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The obstacles for cardiac imaging are motion artifacts due to cardiac motion, respiration, and blood flow, and low signal due to small tissue volume of heart. To overcome these obstacles, fast imaging technique with ECG gating is utilized. Cardiac exam using MRI comprises of morphology, ventricular function, myocardial perfusion, metabolism, and coronary artery morphology. During cardiac morphology evaluation, double and triple inversion recovery techniques are used to depict myocardial fluidity and soft tissue structure such as fat tissue, respectively. By checking the first-pass enhancement of myocardium using contrast-enhanced fast gradient echo technique, myocardial blood flow can be evaluated. In addition, delayed imaging in 10 - 15 minutes can inform myocardial destruction such as chronic myocardial infarction. Ventricular function including regional and global wall motion can be checked by fast gradient echo cine imaging in quantitative way. MRI is acknowledged to be practical for integrated cardiac evaluation technique except coronary angiography. Especially delay imaging is the greatest merit of MRI in myocardial viability evaluation.

  • PDF