• Title/Summary/Keyword: Volume Axial

Search Result 370, Processing Time 0.021 seconds

Direct Numerical Simulation of 3-Dimensional Axial Turbulent Boundary Layers with Spanwise Curvature

  • Shin, Dong-Shin
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.441-447
    • /
    • 2000
  • Direct numerical simulation has been used to study turbulent boundary layers with convex curvature. A direct numerical simulation program has been developed to solve incompressible Navier-Stokes equations in generalized coordinates with the finite volume method. We considered two boundary layer thicknesses. When the curvature effect is small, mean velocity statistics show little difference with those of a plane channel flow. Turbulent intensity decreases as curvature increases. Contours suggest that streamwise vorticities are strong where large pressure fluctuations exist.

  • PDF

Surge Phenomena Analytically Predicted in a Multi-stage Axial Flow Compressor System in the Reduced-Speed Zone

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.3
    • /
    • pp.110-124
    • /
    • 2014
  • Surge phenomena in the zone of reduced speeds in a system of a nine-stage axial flow compressor coupled with ducts were studied analytically by use of a surge transient simulation code. Main results are as follows. (1) Expansion of apparently stable, non-surge working area of the pressure vs. flow field beyond the initial stage-stall line was predicted by the code in the lower speed region. The area proved analytically to be caused by significantly mismatched stage-working conditions, particularly with the front stages deep in the rotating stall branch of the characteristics, as was already known in situ and in steady-state calculations also. (2) Surge frequencies were found to increase for decreasing compressor speeds as far as the particular compressor system was concerned. (3) The tendency was found to be explained by a newly introduced volume-modified reduced surge frequency. It suggests that the surge frequency is related intimately with the process of emptying and filling of air into the delivery volume. (4) The upstream range of movement of the fluid mass having once passed through the compressor in surge was found to reduce toward the lower speeds, which could have caused additionally the increase in surge frequency. (5) The concept of the volume-modified reduced surge frequency was able to explain, though qualitatively at present, the behaviors of the area-pressure ratio parameter for the stall stagnation boundary proposed earlier by the author.

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

The Study on Performance of an Axial Fan with Centrifugal type Blades in Duct flow (덕트 내 원심식 축류팬의 성능변화에 관한 연구)

  • Han, Jae-Oh;Lee, Soo-Young;Yu, Seung-Hun;Lee, Jai-Kwon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.213-216
    • /
    • 2006
  • This paper was a study about noise reduction through flow stabilization in duct using experimental method and numerical analysis at the same time. To determine the fan's type three kinds of fans(axial fan, centrifugal fan, and axial fan with centrifugal type blades) was examined to investigate the suitability for in-line duct. As a result, under the equal number of rotation 2000 RPM, performance of an axial fan with centrifugal type blades was the most superior by 55dBA at 4.3CMM among other fans. After this, analyzed the results of the numerical analysis to find out the optimum design of pitch angle such as $0^{\circ}$, $10^{\circ}$, $15^{\circ}$ and $20^{\circ}$. The intensity of turbulence was low when pitch angle was $15^{\circ}$ and air volume became peak by 5.08 CMM. It was observed that axis component of velocity increased gradually when pitch angle increased from $0^{\circ}$ to $20^{\circ}$, and embodied noise reduction and improvement of air flow rate through flow stabilization.

  • PDF

Change in Axial Rotation of Toric Soft Contact Lens according to Tear Volume (눈물양에 따른 토릭 소프트콘택트렌즈의 축 회전양 변화)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.445-454
    • /
    • 2015
  • Purpose: The present study was aimed to investigate the effect of tear volume on a change of axial rotation according to wearing time of toric soft contact lens and gaze directions. Method: Toric soft contact lenses with double thin zone design applied on 62 eyes. Then, changes in non invasive tear film break-up time and the rotational direction/amount of lens when changing gaze direction were respectively measured after 15 minutes and 6 hours of lens wear. Results: Lens rotation to temporal direction was more found when changing gaze direction after lens wear. However, its rotation was varied according to wearing time and the subjects' tear volume. Furthermore, the frequency of lens rotation to temporal direction was higher in dry eyes compared with normal eyes at nearly all gaze directions after 15 minutes and 6 hour of lens wear. The rotational amount of lens was generally greater in dry eyes after 15 minutes of lens wear. However, its difference between normal eyes and dry eyes was not great after 6 hours of lens wear. Conclusion: The present study revealed that axial rotation of toric soft contact lens was varied according to the wearer's tear volume and lens rotational patterns at the initial, and extending periods of lens wear were different. The change in rotational pattern of toric soft contact lens from these results means the possibility of visual change after extending lens wear, and the identification of its correlation with tear volume suggests the necessity of considering factors for choosing appropriate toric soft contact lens.

Steel Fiber Reinforcement for Shear Capacity Enhancement of High Strength RC Columns (고강도 RC 기둥의 전단능력 증진을 위한 강섬유 보강)

  • 장극관;이현호;문상덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.469-474
    • /
    • 2002
  • This study was to define the strengthening effect of steel fibers in high strength RC columns. For this, ten specimens of columns were tested under cyclic lateral load and constant axial load. The testing parameters are steel fiber volume fraction of concrete and shear reinforcement ratio of hoop bars. Finally, the optimal content of steel fibers was evaluated as 1.0 - 1.5 % volume fraction of concrete.

  • PDF

Application of graded harmonic FE in the analysis of 2D-FGM axisymmetric structures

  • Karakas, Ali I.;Daloglu, Ayse T.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.3
    • /
    • pp.473-494
    • /
    • 2015
  • A graded harmonic finite element formulation based on three-dimensional elasticity theory is developed for the structural analysis of 2D functionally graded axisymmetric structures. The mechanical properties of the axisymmetric solid structures composed of two different metals and ceramics are assumed to vary in radial and axial directions according to power law variations as a function of the volume fractions of the constituents. The material properties of the graded element are calculated at the integration points. Effects of material distribution profile on the static deformation, natural frequency and dynamic response analyses of particular axisymmetric solid structures are investigated by changing the power law exponents. It is observed that the displacements, stresses and natural frequencies are severely affected by the variation of axial and radial power law exponents. Good accuracy is obtained with fewer elements in the present study since Fourier series expansion eliminates the need of finite element mesh in circumferential direction and continuous material property distribution within the elements improves accuracy without refining the mesh size in axial and radial directions.

A Variation of Maximum Stress with Axial Loading in Porcelain Insulators for Transmission Line using ANSYS (ANSYS를 이용한 송전용 자기재 애자의 장력에 따른 특성 변화)

  • Woo, B.C.;Han, S.W.;Cho, H.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.104-107
    • /
    • 2003
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing. These simulation analysis and experimental results show that axial loading affects of Porcelain insulators severely to be mechanical failure ageing.

  • PDF

A Study on Performance Characteristics of an Axial Compressor with the Casing Groove (케이싱 그루브가 존재하는 축류압축기의 성능특성 연구)

  • Choi, Kwang-Jin;Kim, Jin-Hyuk;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.2
    • /
    • pp.24-29
    • /
    • 2010
  • This paper presents a study on the performance of NASA Rotor 37 with the casing grooves based on three-dimensional numerical analysis. Reynolds-averaged Navier-Stokes equations are solved on a hexahedral grid with the shear stress transport model as a turbulence closure model. The governing equations are discretized by a finite volume method. The validation of the numerical results is performed through experimental data for the total pressure ratio and the adiabatic efficiency. The investigation for an axial compressor with a smooth casing and the casing grooves is carried out to compare the performance parameters, for example, surge margin and efficiency, etc. The surge margin is improved in the case of the casing grooves while remarkable improvement of the efficiency is not produced. The result shows that the casing groove is beneficial to expand the operating range of NASA Rotor 37.

Prediction of Permeability for Multi-axial Braided Preform by Using CVFEM (검사체적 유한요소법을 이용한 다축 브레이드 프리폼의 투과율 계수 예측)

  • Y. S. Song;K. Chung;T. J. Kang;J. R. Youn
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.68-70
    • /
    • 2002
  • Prediction of 3-D permeability tensor for multi-axial preform is critical to model and design the manufacturing process of composites by considering resin flow through the multi-axial fiber structure. In this study, the in-plane and transverse permeabilities for braided preform are predicted numerically. The flow analyses are calculated by using 3-D CVFEM(control volume finite element method) for macro-unit cells. To avoid checker-board pressure field and improve the efficiency of numerical computation, a new interpolation function for velocity is proposed on the basis of analytic solutions. Permeability of a braided preform is measured through unidirectional flow experiment and compared with the permeability calculated numerically. Unlike other studies, the current study is based on more realistic unit cell and prediction of permeability is improved.

  • PDF