• 제목/요약/키워드: Voltage-to-time conversion circuit

검색결과 51건 처리시간 0.025초

직접전력변환 방식을 이용한 전압 강하/상승 보상기의 구현 (Implementation of Voltage Sag/Swell Compensator using Direct Power Conversion)

  • 이상회;차한주;한병문
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1544-1550
    • /
    • 2009
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is proposed. A new compensator consists of input/output filter, series transformer and direct ac-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy or compensating voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method that is commonly employed in the direct power conversion. Simulation and experimental results are shown to demonstrate the advantages of the new compensator and PWM strategy. A 220V, 3kVA single-phase compensator based on the digital signal processor controller is built and tested.

역률개선회로를 갖는 에어컨용 전력변환장치 (Air-conditioner Power Conversion Equipment with Power Factor Correction Circuit)

  • 문상필;서기영;이현우;김영문
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.345-351
    • /
    • 2000
  • To improve the current waveform of diode rectifiers, we propose a new operating principle of the voltage diode rectifiers. In the conventional voltage rectifier circuit, relatively large capacitors are used to boost the output voltage, while the proposed circuit uses ones and a small reactor not boost the output voltage but improve the input current waveform. A circuit design method is shown and confirmed simulation. It explained that compared conventional PWM(Pulse-width modulated)inverter with HPWM(Half Pulse-width modulated)inverter. Proposed HPWM inverter eliminated dead-time by lowering switching loss and holding over-shooting. Output voltage and current of this paper were applied for real air-conditioner.

  • PDF

직접전력변환 방식을 이용한 새로운 전압 sag/swell 보상기 (New Voltage Sag/Swell Compensator Using Direct Power Conversion Method)

  • 차한주;이대동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.267-269
    • /
    • 2006
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is introduced. A new compensator consists of input/output filter, series transformer and direct ac-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc-link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy to compensate voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method commonly required in the direct power conversion. Simulation results are shown to demonstrate the advantages of the new compensator and PWM strategy.

  • PDF

직접전력변환 방식을 이용한 전압 sag/swell 보상기의 구현 (Implementation of Voltage Sag/Swell Compensator Using Direct Power Conversion Method)

  • 차한주;이대동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1014-1015
    • /
    • 2006
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is introduced. A new compensator consists of input/output filter, series transformer and direct at-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc-link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy to compensate voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method commonly required in the direct power conversion. Simulation results are shown to demonstrate the advantages of the new compensator and PWM strategy.

  • PDF

디지털 변환신호와 동기화된 클록을 사용하는 아날로그-디지털 변환기 (Analog-to-Digital Conveter Using Synchronized Clock with Digital Conversion Signal)

  • 최진호;장윤석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.522-523
    • /
    • 2017
  • 전류컨베이어 회로와 시간-디지털 변화기를 이용하여 아날로그-디지털 변환기를 설계하였다. 전류컨베이어 회로를 이용하여 아날로그 전압의 크기를 샘플링한 다음, 전류원을 이용하여 샘플링 전압을 방전하면서 아날로그 전압을 시간정보로 변환하였다. 시간정보는 카운터 타입의 시간-디지털 변환기를 이용하여 디지털 값으로 변환되는데 이때 변환 에러를 감소시키기 위해 시간정보 펄스와 동기화된 클록을 생성하여 사용하였다.

  • PDF

LLC Resonant Converter with Hold-up Time Extension Technique for Computer Power Supply

  • Choi, Seong-Wook;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.228-230
    • /
    • 2008
  • A LLC resonant converter with hold-up time extension technique for computer power supply is proposed. Since the proposed circuit has a current boost-up capability of resonant inductor regardless of the input voltage level and the load power condition, operating near the resonant frequency, it can provide the power to the load as the input voltage drops to half of reflected output voltage to the transformer primary. This extends the hold-up time of computer power supply and improves the system power density and conversion efficiency at nominal input voltage. The experimental results with prototype are given to confirm the validity of the proposed circuit.

  • PDF

옵셋전압을 저감시킨 실리콘 바이폴라 홀 IC 설계 (Design of HALL effect integrated circuit with reduced wolgate offset in silicon bipolar technology)

  • 김정언;홍창희
    • 전자공학회논문지A
    • /
    • 제32A권1호
    • /
    • pp.138-145
    • /
    • 1995
  • The offset voltage in silicon Hall plates is mainly caused by stress and strain in package, and by alignment in process. The offset voltage is appeared random for condition change with time in the factory, is non-linearly changed with temperature. In this paper proposed new method of design of Hall IC, and methematicaly proved relation layout of chip of 90$^{\circ}$-shift-current Hall plate pair is matched with "Differentail to single ended Conversion amplifier." In the experiment, the offset voltage is reduced about 1/100 time than the original offset voltage.

  • PDF

제어전극을 갖는 방전소자의 방전개시전압 설계에 관한 연구 (A Study on the Design of Discharge Voltage of Discharge Element with Control Electrode)

  • 박근석;최준웅;이대동
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1512-1516
    • /
    • 2018
  • The power system and control system constantly reveals surge voltage such as switching surge of lighting devices and power conversion devices, operating and stops surge of rotating devices, charge & discharge surge, opening & closing surge of circuit breakers and the like. Such a surge voltages can cause damage or malfunction of the element such as CPU, Memory, semiconductor etc. In the industry, in order to protect the system from the surge voltage, a surge protector with low discharge starting voltage, fast response time, and low capacitance is required, and technical development research for that is ongoing. In this paper, in order to solve the problem of the existing GDT discharge tube not discharging from the transient voltage which is higher than the commercial voltage and lower than the discharge voltage of the discharge element, we have developed a discharge element having the control electrode & control circuit. The discharge element having the control electrode and the control circuit can control the discharge voltage according to the needs of the consumer and can satisfy the requirement of the discharge element and the technology of the surge protector downsizing technology and the surge protection technology. It is judged to be effective for development.

A Differential Current-to-Time Interval Converter Using Current-Tunable Schmitt Triggers

  • Chung, Won-Sup
    • 전기전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.375-380
    • /
    • 2017
  • A differential current-to-time interval converter is presented for current mode sensors. It consists of a ramp voltage generator, a current mode sensor, a reference current source, two current-tunable Schmitt triggers, a one-shot multivibrator, and two logic gates. The design principle is to apply a ramp voltage to each input of the two current-tunable Schmitt triggers whose threshold voltages are proportional to the drain current values of the current mode sensors. A proposed circuit converts a current change in the ISFET biosensor into its equivalent pulse width change. A prototype circuit built using TSMC 0.18 nm CMOS process exhibit a conversion sensitivity amounting to $726.9{\mu}s/pH$ over pH variation range of 2-12 and a linearity error less than ${\pm}0.05%$.

Analysis of Voltage Stress in Stator Windings of IGBT PWM Inverter-Fed Induction Motor Systems

  • Hwang Don-Ha;Lee Ki-Chang;Jeon Jeong-Woo;Kim Yong-Joo;Lee In-Woo;Kim Dong-Hee
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.43-49
    • /
    • 2005
  • The high rate of voltage rise (dv/dt) in motor terminals caused by high-frequency switching and impedance mismatches between inverter and motor are known as the primary causes of irregular voltage distributions and insulation breakdowns on stator windings in IGBT PWM inverter-driven induction motors. In this paper, voltage distributions in the stator windings of an induction motor driven by an IGBT PWM inverter are studied. To analyze the irregular voltages of stator windings, high frequency parameters are derived from the finite element (FE) analysis of stator slots. An equivalent circuit composed of distributed capacitances, inductance, and resistance is derived from these parameters. This equivalent circuit is then used for simulation in order to predict the voltage distributions among the turns and coils. The effects of various rising times in motor terminal voltages and cable lengths on the stator voltage distribution are also presented. For a comparison with simulations, an induction motor with taps in the stator turns was made and driven by a variable-rising time switching surge generator. The test results are shown.