• Title/Summary/Keyword: Voltage to Current Convertor

Search Result 16, Processing Time 0.025 seconds

A New Current-Fed Isolated Boost Converter for Battery Powered Applications (축전지 구동 응용을 위한 새로운 승압형 DC/DC 컨버터)

  • 노정욱;한승훈;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.646-649
    • /
    • 1999
  • A new isolated boost dc to dc convertor suitable for a low input voltage application is proposed. The proposed convertor features the low switch current stresses, the wide input voltage range operation, and the inherent inrush current protection characteristics, essential to design a low to high voltage conversion circuit. A comparative analysis and experimental results are presented to show the validity of the proposed convertor.

  • PDF

Establishment of Evaluation System for 40,000 A Rogowski Coil (40,000 A 로고스키 코일 평가 시스템 구축)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Kang, Jeon-Hong;Lee, Sang-Hwa;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.202-206
    • /
    • 2009
  • Evaluation system for calibrating Rogowski coiI(RC) up to primary current of 40,000 A have been established. The system consists of 40,000 A AC high current source, current transformer(CT) comparator, standard CT, RC under test, voltage to current convertor(VCC), buffer and CT burden. An AC high current is applied to the primary windings of both the standard CT and the RC under test, and then the CT comparator measures the ratio error and the phase displacement by comparing the secondary current of the standard CT with output current of VCC. For testing of RC, we have evaluated two RCs under test of primary current ranges of 0 A ${\sim}$ 2,000 A and 0 A ${\sim}$ 40,000 A with the accuracy class of 1 %. The extended uncertainty is 0.02 % ${\sim}$ 0.23 % for ratio error and 0.29 min ${\sim}$ 1.93 min for phase displacement in the primary current ranges of 10 ${\sim}$ 40,000 A.

Reactive Current Assignment and Control for DFIG Based Wind Turbines during Grid Voltage Sag and Swell Conditions

  • Xu, Hailiang;Ma, Xiaojun;Sun, Dan
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.235-245
    • /
    • 2015
  • This paper proposes a reactive current assignment and control strategy for a doubly-fed induction generator (DFIG) based wind-turbine generation system under generic grid voltage sag or swell conditions. The system's active and reactive power constrains during grid faults are investigated with both the grid- and rotor-side convertors (GSC and RSC) maximum ampere limits considered. To meet the latest grid codes, especially the low- and high-voltage ride-through (LVRT and HVRT) requirements, an adaptive reactive current control scheme is investigated. In addition, a torque-oscillation suppression technique is designed to reduce the mechanism stress on turbine systems caused by intensive voltage variations. Simulation and experiment studies demonstrate the feasibility and effectiveness of the proposed control scheme to enhance the fault ride-through (FRT) capability of DFIG-based wind turbines during violent changes in grid voltage.

Power Factor Correction Method without Input Current Sensor (입력전류센서 없는 단상전력변환기의 역률개선 기법)

  • Jung, Young-Seok;Moon, Gun-Woo;Rho, Chung-Wook;Lee, Jun-Young;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.564-566
    • /
    • 1996
  • New simple control method of power factor correcting(PFC) boost convertor without instantaneous measurement of input current is proposed. Using the averaged model, the power factor correction scheme is presented. With the measurements of input voltage and output voltage, the control signal is generated to make the shape of the line current same as the input voltage. The validity of the controller is verified through the computer simulations.

  • PDF

Buck+Half Bridge Converter efficiency characteristics (벅+하프 브리지 컨버터에서 벅 컨버터의 출력 인덕턴스 감과 스위칭 주파수, 변압기 코어 형태에 따른 효율 특성)

  • Park N.J.;Kim C.S.;Kim T.S.;Im B.S.;Woo S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.62-65
    • /
    • 2003
  • We considered of the efficiency for the Buck+Half bridge converter This converter has advantages of applications for a low output voltage, a high output current and a wide input voltage. Developed the Buck converter ratings and the Half Bridge converter ratings are 36$\~$72V Input and 22V/5A output, 19$\~$24v input and 3.3V/30A output, respectively. Buck converter is operated with zero voltage switching process to reduce the switching losses. The 80.1 $\~$97.6$\%$ of the efficiency is measured at 18.4 $\mu$H output filter inductance of Buck convertor. In Half Bridge convertor, the 86$\~$96.4$\%$ of the efficiency is measured at 100kHz switching frequency with PQI core.

  • PDF

Analysis of Current Mode Controlled Zero Voltage Switching Half Bridge PWM Converter (전류모드로 제어되는 영전압 스위칭 하프 브리지 PWM 컨버터의 해석)

  • 정영석;권순재
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.64-69
    • /
    • 2003
  • There exist the high frequency components, which can not be predicted by the low frequency model, due to the presence of sampling effect in current mode control. In this paper, the output voltage equations for the ZVS half bridge PWM convertor are derived from the steady state analysis, and the sampling gain presented in the current control loop is Investigated to improve the Prediction Performance of low frequency model of ZVS half bridge PWM converter.

Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters (2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상)

  • Kim Young-Sin;Lee Dong-Choon;Seok Jul-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

A Study on Dynamic Stability of HVDC System Type which may be Applied the Jeju AC Network (제주계통에 적용 가능한 유형별 HVDC 시스템의 동적 안정도 연구)

  • Kwon, Young-Hun;Kim, Yong-Hak;Kim, Chan-Ki;Choy, Young-Do
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.270-277
    • /
    • 2008
  • Capacitor Commutated Converter HVDC system is required the small reactive power. It has the advantage of an application to the week grid because the firing angle ${\alpha}$ can be increased to a value well beyond $180^{\circ}$. In this paper, The three HVDC converter arrangements which are the CCC(Capacitor Commutated Converter) and the CSCC(Controlled Series Capacitor Convertor) and Conventional Converter are compared the dynamic character. and it find that the CCC HVDC is operating with more reliability. The simulation was conducted to the PSCAD/EMTDC.

A Study on the High-Efficiency. High-Power-Factor AC/DC Boost Converter Using Energy Recovery (에너지 회생 스너버를 적용한 고효률, 고역률 AC/DC Boost 컨버터에 관한 연구)

  • Ryu, Chang-Gyu;Kim, Yong;Bae, Jin-Yong;Baek, Soo-Hyun;Choi, Geun-Soo;Gye, Sang-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.160-163
    • /
    • 2004
  • A passive lossless turn-on/turn-off snubber network is proposed for the boost PWM converter. Previous AC/DC PFC Boost Converter perceives feed forward signal of output for average current-mode control. Previous Boost Convertor, the Quantity of input current will be decreased by the decrease of output current in light load, and also Power factor comes to be decreased. Also the efficiency of converter will be decreased by the decrease of power factor. The proposed converter presents the good PFC, low line current harmonic distortions and tight output voltage regulations using energy recovery circuit. All of the semiconductor devices in the converter are turned on under exact or near zero voltage switching(ZVS). No additional voltage and current stresses on the main switch and main diode occur. To show the superiority of this converter is verified through the experiment with a 640W, 100kHz prototype converter.

  • PDF

EMTP Simulation of Bipolar HVDC System (바이폴 HVDC 시스템의 EMTP 시뮬레이션)

  • Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1053-1055
    • /
    • 1998
  • Using EMTP model which describes bipolar HVDC system, switching level simulation results are presented in this paper. Voltage synchronization at point of common coupling, gate pulse generation and current control loops are represented in TACS module. The system consists of 100 km submarine cable rated 300 MW and 12 pulse rectifier and inverter stations which are connected to equivalent three-phase sources and loads through the 154 kV AC lines, respectively. In convertor stations, harmonic filters and capacitor banks are equipped to cancel out the harmonics generated by converters and to supply the required reactive power.

  • PDF