• Title/Summary/Keyword: Voltage surge

Search Result 446, Processing Time 0.028 seconds

Study on Surge Absorption Capability for Power Arrester with MOV Micro-milling Characteristics (전력용 피뢰기의 MOV 미립화와 에너지 내량 특성 연구)

  • Han, Se-Won;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.120-124
    • /
    • 2004
  • The protection performance and energy absorption capability are important for both MOAs for distribution lines and MOAs for high voltage systems, therefore the manufacturing technique of ZnO varistor elements with high ability against surge impacts is great important for high voltage systems. But until now ZnO varistors for low voltage class have been developed in Korea, ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems depend on an import from advanced countries, such as Japan or U.S.A, which have developed its in the late 1980s. So in the aspect of taking independent technique the development of ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems is important. In this research project ZnO varistor elements with diameters of 35mm and 70mm for the rate discharge current of 5, 10kA class for high voltage systems are manufactured, then various chemical composition and processing variables affected the electrical and the physical characteristics of these ZnO varistors are investigated.

  • PDF

Effect of Sintering Temperature on Electrical Stability against Surge Stress of Zn-Pr-Co-Cr-Er Oxides-based Varistors (Zn-Pr-Co-Cr-Er 산화물계 바리스터의 써지 스트레스에 대한 전기적 안정성에 미치는 소결온도의 영향)

  • Nahm, Choon-Woo;Park, Jong-Ah;Yoo, Dea-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1167-1173
    • /
    • 2004
  • This paper reports the variations of varistor voltage, nonlinear exponent, leakage current, and dissipation factor against surge stress of ZnO-P $r_{6}$ $O_{11}$-CoO-C $r_2$ $O_3$-E $r_2$ $O_3$(ZPCCE)-based varistors manufactured with the variations of sintering temperature. It was found that the variations of electrical parameters against surge stressing current of 100 A/$\textrm{cm}^2$(8x20 ${\mu}\textrm{s}$) is not so large under the surge stress of 700 times. Among varistors, specially the varistor sintered at 134$0^{\circ}C$ exhibited the smallest variations, with %$\Delta$ $V_{lmA}$=+0.23%, %$\Delta$$\alpha$=+0.23%, %$\Delta$ $I_{L}$=0%, %$\Delta$tan$\delta$=-6.94%. The clamping voltage ratio( $V_{c}$/ $V_{lmA}$) of all varistors was less than 2.2.2.2.2.2.2.

Failure Rate Estimation of MOV for Condition Monitoring of Surge Protective Devices (서지보호기의 상태 감시를 위한 MOV의 고장률 예측)

  • Kim, Dong Jin;Kim, Young Sun;Park, Jae Jun;Lee, Ki Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1302-1307
    • /
    • 2013
  • MOV(Metal Oxide Varistor) is the most important part of SPD(Surge Protective Device) which can protect electric facilities from an impulse current such as a lightning. So far, the fault of MOVs have decided only by surge count without considering magnitude of surge current and an amount of input energy. This paper proposed the fault prediction algorithm for the MOV using look up table made by surge count and input current data which have non-linear characteristics for input current and are estimated by high voltage experimental results. Proposed algorithm was proved by experiment on verification at a high voltage laboratory.

Propagation Aspect of Lightning Surge According to The Arrangement of Indoor wire (옥내배선 배치에 따른 서지 전파양상)

  • Lee, Suck-Woo;Whang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.658-661
    • /
    • 2004
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society And electrical circuits with semiconductor are very weak against lightning surge. To achieve effective method of surge protection on low voltage lines, there are needs for the relationship between propagation aspects of lightning surge and arrangement of indoor wire. This paper describes the experimental study on the relationship between them. This result may be raw data for establishment of surge protection system.

  • PDF

Experimental Study of Overvoltage Phenomena due to Lightning Surge (뇌서지에 의한 과전압 현상에 대한 실험연구)

  • Lee, Suck-Woo;Ko, Yeon-Sung;Yeo, Dong-Goo;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.80-82
    • /
    • 2005
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society. And electrical circuits with semiconductor are very weak against lightning surge. To achieve effective method of surge protection on low voltage lines, there are needs for the relationship between propagation aspects of lightning surge and arrangement of indoor wire. This paper describes the experimental study on the relationship between them. This result may be raw data for establishment of surge protection system.

  • PDF

Features of Transient Overvoltages Observed at 22.9kV Consumer's Substation (22.9kV 수전설비에서 측정된 과도과전압의 특성)

  • Shim, Hae-Sup;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.52-59
    • /
    • 2014
  • The aims of this paper are to characterize the transient overvoltages(TOVs) and to evaluate the risk occurring at 22.9kV consumer's substation. The measurements of lightning- and switching-caused TOVs were made during Mar. 2013 and Feb. 2014. As a consequence, 47 events of TOVs were recorded and 4 of them were higher than the input voltage envelope(IVE) of the information technology industry council(ITI) curve. The measured TOVs are characterized by longer front times and longer durations compared to the $1.2/50{\mu}s$ standard impulse voltage waveform, and some of them represent bipolar waves with lower oscillation frequencies. It suggests that the test of non-standard impulse voltage waveforms is needed for effective risk assessments of power apparatus. Lightning- and switching-caused TOVs exceeding IVE of ITI curve are induced at the secondary of 22.9kV potential transformer(PT). We may, therefore, conclude that the surge protection devices should be applied at the secondary of PT and the surge absorbers should be installed at the primary of VCB or PT. The results presented in this paper could be useful to design the reasonable insulation coordination for 22.9kV consumer's substation.

An Analysis on Surge Voltage Transfer Phenomena of Transformers by Minor Network (Minor netowrk에 의한 변압기의 충격전압파의 이행현상해석)

  • 이승원
    • 전기의세계
    • /
    • v.20 no.6
    • /
    • pp.7-18
    • /
    • 1971
  • Secondary-side transfer phenomena of primary-side surge voltage in concentric-cylindrical transformers of a high turn-ratio still present a problem in transformer insulation design even in the case of a neutral solid-grounding type. The conventional methods of analyzing them so far are much complicated for practical applications. Therefore, this paper describes a new approach to the analysis of secondary-side transfer phenomena of surge in concentric-cylindrical transformers of high turn-ratio and solid-grounding type. This generalized approach is thought to be more simple with the use of minor network concepts than the conventional one by major network only. The result shows that the secondary-side transfer phenomena of surge voltage could not be neglected even in concentric-cylindrical transformer of high turn-ratio and solid-grounding type, and will be satisfactorily applicable to the design of neutral-solid-grounding type transformers.

  • PDF

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF

Analysis on Surge generated in N Module Paralleled Capacitor Bank and Countermeasure for Suppression (N개 모듈로 구성된 커패시터 뱅크의 써지전압 발생 원인 분석 및 억제 대책)

  • Kim, Jin-Sung;Choi, Young-Ho;Jung, Jae-Won;Chu, Jeung-Ho;Sung, Gi-Yeul;Jin, Yun-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1597-1599
    • /
    • 2001
  • In this paper, two types of surge voltage generated in the only operation of capacitor bank composed of paralleled multi-modules are analyzed and also studied to suppress those. The surge voltage can give malfuction to the operation of capacitor bank and destroy the expensive components at the worst. The conditions and causes of surge voltage generation and the countermeasure for suppression are presented.

  • PDF

Electrical Characteristics of ZnO Surge Arrester Elements Subjected to the Mixed DC and 60[Hz] AC Voltages (직류+60[Hz] 교류 중첩전압에 대한 ZnO 피뢰기 소자의 전기적 특성)

  • Lee, Bok-Hee;Yang, Soon-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.41-47
    • /
    • 2012
  • This paper deals with the electrical characteristics related to power loss, equivalent resistance, and leakage currents flowing through new and deteriorated zinc oxide(ZnO) arrester elements subjected to the mixed DC and 60[Hz] AC voltages. The test specimens were deteriorated by 8/20[${\mu}s$] impulse current of 2.5[kA]. The leakage current-applied voltage($I-V$) characteristic curves of ZnO surge arrester elements were measured as a parameter of the ratio of the peak of 60[Hz] AC voltage to the peak of total voltage. As a consequence of test results, in case of the same applied voltage, the leakage currents flowing through the deteriorated ZnO arrester elements were higher than those flowing through the new ZnO surge arrester elements. The cross-over phenomenon in $I-V$ curves of ZnO surge arrester elements measured as a parameter of the mixed ratio of DC and AC voltages was observed at the low current domain. The effect of DC voltage on the leakage current flowing through ZnO surge arrester elements is pronounced at the same magnitude of test voltages. In addition, the larger the applied number of 8/20[${\mu}s$] impulse current of 2.5[kA] is, the greater the power loss is, in particular, the more severe the power loss increases at higher applied voltages.