• 제목/요약/키워드: Voltage oriented control

검색결과 61건 처리시간 0.028초

Decoupled Control of Doubly Fed Induction Machine Fed by SVM Matrix Converter

  • Dendouga, Abdelhakim;Abdessemed, Rachid;Bendaas, Mohamed Lokmane
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.491-498
    • /
    • 2008
  • In this paper a decoupled control of a doubly-fed induction machine(DFIM) feed by a matrix converter is presented. It provides a robust regulation of the stator side active and reactive powers by the direct and quadratic components of the stator current vector, presented in a line-voltage-oriented reference frame. In this case, the stator windings are directly connected to the line grid, while the rotor windings are supplied by this later through a matrix converter controlled by a space vector modulation technique. The proposed solution is suitable for both energy generation and electrical drive applications with restricted speed variation range.

칼만 필터를 이용한 영구자석 동기 전동기의 고정자 저항값 검출 방법 (Stator Resistance Estimation of Permanent Magnet Synchronous Motor by using Kalman Filter)

  • 황상진;이동명
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.92-98
    • /
    • 2019
  • Accurate estimation of motor parameters is required in some motor control applications. For example, the value of stator resistance is required for stator flux-oriented control mostly used in doubly fed induction generator systems. Stator resistance is not a constant value and continuously changes due to the rise in temperature during motor operation. Estimation errors degrade the control performance. Hence, this study proposes a simple stator resistance estimation method. In this scheme, the differential components of voltage and current values are used to eliminate the dead-time effect, and Kalman filter algorithm is applied to reduce the error according to measurement noise. Simulation and experimental results obtained with a permanent magnet motor show the validity of the proposed algorithm.

유도전동기 구동시스템을 위한 가변구조 전류제어기의 설계 (Design of Variable Structure Current Controller for Induction Motor Olives)

  • 차정화;노영남;전희종;박종찬;손진근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.1954-1956
    • /
    • 1997
  • In this paper, a variable structure current control scheme for field-oriented induction motor drive is presented. The current controller based on space voltage vector PWM scheme consists of feedforward, decouple and variable structure control. The proposed current controller tracks reference value quickly, has robust property against parameter variation and disturbance, reduces switching frequency and improves performance of induction motor drive. Finally, the proposed current controller is verified by digital simulation

  • PDF

신경 회로망을 이용한 Relay 작동전압 조정 자동화 시스템 개발 (Development of automation system for relay on/off voltage adjustment using neural network)

  • 국금환;최동엽
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.43-48
    • /
    • 1992
  • The automation system oriented as one of the second year automation projects for the small and medium sized enterprises(SME) was developed for the improvement of the production rate and cut the required manpower in the field of the relay which is one of the small electric components used in various industrial fields. The objectives of this study are not only improving the international competition of the relay itself but also partially solving the technical and financial problems featured by common bottlenecks of the SME for efficient assembly automation. For the purpose of these objectives, several topics are studied as followings. - Analyzing the adjustment process and determining the specification of the automation system. - Determining the layout for the automation system to meet the determined specification. - Detail design of the automation system for relay adjustment and inspection. - Control system design - Automation system development and performance test.

  • PDF

차량용 VVVF 인버터 제어시스템 개발 (Development of VVVF Inverter Control System for Propulsion System)

  • 김병섭;이규찬;이학성;김송웅;박영춘;김중한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.249-251
    • /
    • 1994
  • This paper introduces an implementation of high performance voltage source inverter system based on 16bit micro-processor and DSP for the application to modem rolling stock traction system. In contrast with other industry oriented inverter system, this system requires precise control action complying with various load condition and high overload capability. An asynchronous PWM generation and 3' pulse mode technology are adopted in order to improve compliant starting torque characteristics at starting phase and soft backward-forward starting motion.

  • PDF

Reduced-order Mapping and Design-oriented Instability for Constant On-time Current-mode Controlled Buck Converters with a PI Compensator

  • Zhang, Xi;Xu, Jianping;Wu, Jiahui;Bao, Bocheng;Zhou, Guohua;Zhang, Kaitun
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1298-1307
    • /
    • 2017
  • The constant on-time current-mode controlled (COT-CMC) switching dc-dc converter is stable, with no subharmonic oscillation in its current loop when a voltage ripple in its outer voltage loop is ignored. However, when its output capacitance is small or its feedback gain is high, subharmonic oscillation may occur in a COT-CMC buck converter with a proportional-integral (PI) compensator. To investigate the subharmonic instability of COT-CMC buck converters with a PI compensator, an accurate reduced-order asynchronous-switching map model of a COT-CMC buck converter with a PI compensator is established. Based on this, the instability behaviors caused by output capacitance and feedback gain are investigated. Furthermore, an approximate instability condition is obtained and design-oriented stability boundaries in different circuit parameter spaces are yielded. The analysis results show that the instability of COT-CMC buck converters with a PI compensator is mainly affected by the output capacitance, output capacitor equivalent series resistance (ESR), feedback gain, current-sensing gain and constant on-time. The study results of this paper are helpful for the circuit parameter design of COT-CMC switching dc-dc converters. Experimental results are provided to verify the analysis results.

산업설비 적용을 위한 유도전동기의 고성능 벡터제어에 관한 연구 (A Study on the High-Performance Vector control of Induction Motor for Industrial Application)

  • 손진근;김진상;김병진;김국진;전희종
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권6호
    • /
    • pp.57-64
    • /
    • 1995
  • 본 논문에서는 산업용 구동력으로써 대부분을 차지하는 유도전동기의 가변속 구동시 성능이 우수한 벡터제어 시스템에 관하여 연구하였다. 유도전동기의 회전자 각속도와 고정자 전류에 의한 간접적인 회전자 기준자속 추정방식을 채택하였으며, 이때의 전류제어기는 상호 간섭이 일어나지 않는 비간섭 동기 회전좌표계 PI제어기를 구성하였으며 시스템을 견실하게 하였다. 공간전압벡터 변조기법을 적용하여 전압 이용율의 향상과 전류제어가 용이하도록 하였다. 기기의 모델링 및 디지털 시뮬레이션을 통하여 속응성과 원활한 제어특성이 나타나는 유도전동기 구동시스템임을 입증하였다.

  • PDF

A Study on Highly Efficient Organic Electroluminescent Devices

  • Park, Jae-Hoon;Lee, Yong-Soo;Choi, Jong-Sun
    • Journal of Information Display
    • /
    • 제4권2호
    • /
    • pp.19-24
    • /
    • 2003
  • In order to improve the device performances of organic electroluminescent devices (OELDs), the efficiency of carrier injections into the organic layers from electrodes and the balance of injected carrier densities in the emission region are critical factors. Especially, energy barriers, which exist at the interfaces between electrodes and organic layers, interrupt carrier injections, which lead to unbalanced carrier densities. In this study, ${\alpha}-septithiophene$ (${\alpha}$-7T), as a buffer layer, and composite cathode composed of Al and CsF were formed to improve hole and electron injections, respectively. The orientations of ${\alpha}$-7T molecules were adjusted using the simple rubbing method and the mass ratio of CsF was varied from 1 to 10 wt%. Upon investigation of we believe that the 3 wt% mass ratio of CsF and the horizontal orientation of ${\alpha}$-7T molecules are the optimized conditions for achieving better the performance of OELDs. Device with the horizontally oriented 20 nm thick ${\alpha}$-7T layer and composite cathode shows a turn-on voltage of 7V and luminance of 172 cd/$m^2$ at 4 mA/$cm^2$.

SIMULTANEOUS SPEED AND ROTOR TIME CONSTANT IDENTIFICATION OF AN INDUCTION MOTOR DRIVE BASED ON THE MODEL REFERENCE ADAPTIVE SYSTEM COMBINED WITH A FUZZY RESISTANCE ESTIMATOR

  • Soltani, Jafar;Mizaeian, Behzad
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.11-16
    • /
    • 1998
  • In this paper, simultaneous estimation of rotor speed and time constant for a voltage source inverter (VSI) fed induction motor drive are disccussed. The theory is based on the Model Reference Adaptive System (MRAS). The identifier executes Simultaneous rotor speed and time constant so that vector control of the induction may be achieved in the rotor-flux oriented reference frame. Furthermore, to eliminate the offset error caused by the change in the stator resistance, a fuzzy resistance regulator is also designed which operates in parallel with the rotor speed and time constant identifier

  • PDF

전력계통공학을 위한 웹기반 교육시스템의 개발 (A Web-based Educational Tool for the Power System Engineerings)

  • 이욱화;박인권;이진;윤용범;전동훈;홍준희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.41-43
    • /
    • 2001
  • This paper presents a Web-based educational tool for Power System Engineering, especially for power engineers. This tool has Web-oriented educational courses for power system education. The Web-based learning has become more popular year by year in the various fields[1-2]. The proposed educational tool provides some courses such as power system introduction Course, KEPCO's system introduction Course, Power system devices Course, Power Flow Course, OPF Course, ELD Course, Stability Analysis Course, Fault analysis Course, Voltage & Frequency control Course, and power system planning & operation Course. Finally, it will be scheduled to install for the education tool of the power system engineering for KEPS[3].

  • PDF