• 제목/요약/키워드: Voltage dips

검색결과 19건 처리시간 0.032초

Ride-through of PMSG Wind Power System Under the Distorted and Unbalanced Grid Voltage Dips

  • Sim, Jun-Bo;Kim, Ki-Cheol;Son, Rak-Won;Oh, Joong-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.898-904
    • /
    • 2012
  • This paper presents a ride-through skill of PMSG wind turbine system under the distorted and unbalanced grid voltage dips. When voltage dips occur in the grid, pitch control and generator speed control as well as a parallel resistor of DC-link help to keep the turbine's safety. Modern grid code requires a wind turbine to supply reactive currents to help voltage recovery after grid faults clearance. In order to supply reactive currents to the grid in case of the distortedly unbalanced grid voltage dips, a special PLL is needed to control the grid side converter and to regulate the grid voltages symmetrically. The proposed method is applied to 2MW multi-pole PMSG wind turbine system, and verified by simulation.

소형 열병합 발전설비가 연계된 배전계통의 순시전압변동 (Momentary Voltage Dips in the Power Distribution System Interconnected with Cogeneration Facilities (COGN))

  • 최준호;김재철;정성교;김대원;한성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1088-1090
    • /
    • 1998
  • The cogeneration facilities (COGN) into the power distribution system can cause operational problems - reenergization of distribution feeders under repair by utility personnel, voltage variation and regulation because of output power of COGN, and lost of coordination at emergency state - on an electrical utility system. This paper deals with momentary voltage dips as the parallel interconnection operation of COGN in the power distribution system. PSCAD/EMTDC simulation tool is used to show the behavior of momentary voltage dips. In addition, restraint solution for momentary voltage variation is presented.

  • PDF

A DVR Control for Compensating Unbalanced Voltage Dips of a DFIG System using Zero Sequence Components

  • Thinh, Quach Ngoc;Ko, Ji-Han;Kim, Dong-Wan;Kim, Eel-Hwan
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.62-68
    • /
    • 2013
  • The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results in high insulation costs and asymmetry in terminal voltages. This paper proposes the use of a proportional-resonant controller in stationary reference frames for controlling zero sequence components in the DVR to protect the DFIG during unbalanced voltage dips. To enhance the proposed control method, a comparison is carried out between two cases: with and without using the control of a zero sequence component. Simulation results are presented to verify the effectiveness of the proposed control method by using the Psim simulation program.

A Study on the Reliability of DVR in a 3-Phase Phase-Controlled Rectifier

  • Kim, Woo-Hyun;Park, Chul-Woo
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.54-61
    • /
    • 2012
  • This study investigated the relationship between the response time of DVR (Dynamic Voltage Restorer) and the possible compensation range for voltage dips by the DVR system which protects the 3-phase phase-controlled rectifier from said dips. As a result, the permissible range of voltage dip is presented in a 3-phase phase-controlled rectifier. When the DVR compensates for voltage dip, the range of voltage dip can be compensated according to the DVR's response time. Using the proposed method, DVR response time can be determined from the parameters of the 3-phase phase-controlled rectifier and the possible compensatory range of voltage dip, while at the same time it is possible to use a control system having an appropriate speed. Therefore, the use of excessively fast equipment can be avoided, improving the stability of the overall system. The reliability of the DVR concerning the 3-phase phase-controlled rectifier can be verified by simulation.

Controlling Zero Sequence Component in DVR for Compensating Unbalanced Voltage Dip of a DFIG

  • Ko, JiHan;Thinh, Quach Ngoc;Kim, SeongHuyn;Kim, Eel-Hwan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.154-155
    • /
    • 2012
  • The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generator based on doubly-fed induction generator (DFIG) operated under the unbalanced voltage dip conditions. The compensating voltages of DVR depend on the voltage dips and on the influence of the zero sequence components. If the $Y_0/{\Delta}$ step-up transformers are used, there are no zero sequence components on the DFIG side. However, if the $Y_0/Y_0$ step-up transformers are used, the zero sequence components will appear during faults. The zero sequence components result in the high insulation costs and the asymmetric of the terminal voltages. This paper proposes a method for controlling zero sequence components in DVR to protect DFIG under unbalanced voltage dips. Simulation results are presented to verify the effectiveness of the proposed control method.

  • PDF

자속 추종을 통한 DFIG 시스템의 LVRT 기법 (LVRT Scheme for Doubly Fed Induction Generator Systems Based on Flux Tracking Method)

  • 박선영;전영환;이동명
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1059-1065
    • /
    • 2013
  • Doubly Fed Induction Generator(DFIG) systems occupy the largest proportion of worldwide wind energy generation market. DFIG systems are very sensitive to grid disturbances especially to voltage dips due to the structure of the stator connected to grid. In the past, when a grid fault occurs generators are separated from grid(trip method) in order to protect the systems. Nowadays, due to the growing penetration level of wind power, many countries have made some requirements that wind turbines are required to have Low Voltage Ride Through(LVRT) capability during grid faults. In this paper, a flux tracking LVRT control strategy based on system modeling equations is proposed. The validity of the proposed strategy is verified through computer simulations.

전력계통 전압외란에 대한 자가수용가의 과도 안정도 해석 (Transient Stability of Industrial Plant on Voltage Disturbance in the Utility System)

  • 조양행;정재길
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.132-138
    • /
    • 1998
  • 최근의 자가발전기를 보유한 대용량 수용가에서는 자체의 전력계통올 안정하게 유지하기 위한 명가 방법으로서 안정도 해석올 통한 계통의 문제점을 파악하는 것은 중요한 과제이다. 본 논문은 전력계통에 있어서 대전력계통(한전계통)측의 3상 단락고장시 고장 지속 시간에 따른 자가 발전을 보유한 수용가 전력계통의 전압에 미치는 영향을 조사 분석한 논문으로 한전계통측의 고장 지속 시간에 따라 수용가 계통의 발전기 및 동기기가 불안정하게 된다. 이러한 불안정현상은 후비보호 계전기(저전압 계전기)의 적절한 시간 설정으로 한전계통과 분리하고 수용가의 부하를 차단하므로써 안정도를 증진시킬 수 있다.

  • PDF

발전기 형태를 고려한 열병합발전시스템의 배전계통 연계운전시의 순시전압변동 해석 (Analysis on Momentary Voltage Dips with the Interconnection Operation of Utility-interactive Cogneration Systems Considering Their Generator Type)

  • 최준호;김재철
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.23-30
    • /
    • 2000
  • 열병합발전 시스템은 환경 친화적인 동시에 상대적으로 고 효율의 에너지 시스템으로서 분산 방전설비의 혁신 기술중 하나이다, 아울러 열병합발전 시스템운 열과 전기의 분산공급에 적절한 발전 시스템이다. 그러나, 열병합발전 시스템의 계통 연계는 전압 소정, 전압변동, 보호협조, 안전등의 제반 연제문제를 수반한다. 특히, 이러한 연계문제 중 열병합발전 시스템의 배전계통 연계.분리 운전은 배전계통의 전압조정 및 변동에 영향을 미칠 것이 예상된다. 최근 수용가 소유의 컴퓨터 및 민감한 전자소자의 사용 증가로 인하여 전력품질온 중요한 고려사항이 되고 있다. 따라서 열병합발전 시스템과 관련한 전압품질은 반드시 분석되어야만 한다. 왜냐하면 전압품질은 전력 품질의 중요한 요소이기 때문이다. 본 논문에서는 열병합발전 시스템의 배전계통 연계 운전에 따른 순서전압변통 에 대하여 컴퓨터 시물레이션을 롱하여 분석하였고、 또한 이의 억제 대책을 제시하였다. 아울러 순시전압변동 측면에서 본 피더 당 열병합발전시스템의 단위 도입 용량을 평가하였다. 본 논문의 결과는 열병합발전 시스템 또는 분산형 전원의 계통 연계 표준. 가이드라인에 유용한 자료가 되리라 믿는다.

  • PDF

불평형 계통전압에 강인한 연료전지용 전력변환시스템의 PLL 방법 (A Robust PLL of PCS for Fuel Cell System under Unbalanced Grid Voltages)

  • 김윤현;김왕래;임창진;김광섭;권병기;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.103-105
    • /
    • 2008
  • In grid-interconnection system, a fast, robust and precise phase angle detector is most important to grid synchronization and the active power control. The phase angle can be easily estimated by synchronous dq PLL system. On the other hand under unbalanced voltage condition, synchronous dq PLL system has problem that harmonics occur to phase angle or magnitude of grid voltage because of the effect of the negative sequence components. So, To eliminate the negative sequence components, the PLL method using APF (All Pass Filter) in a stationery reference frame to extract positive sequence components under unbalanced voltage condition is researched. In this paper, we propose a new PLL method with decoupling network using APF in a synchronous reference frame to extract the positive sequence components of the grid voltage under unbalanced grid. The cut-off frequency of APF in a synchronous reference frame can be set to twice of the fundamental frequency comparing with that of APF in a stationery reference frame which is the fundamental frequency. The proposed PLL strategy can detect the phase angle quickly and accurately under unbalanced gird voltages. Simulation and experimental results are presented to verify the proposed strategy under different kind of voltage dips.

  • PDF

DVR 기능을 갖는 3상 하이브리드형 직렬 능동전력필터 (3-Phase Hybrid Series Active Power Filter with Dynamic Voltage Restorer)

  • 한석우;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.598-602
    • /
    • 2002
  • This paper presents the 3-phase hybrid series active power filter with dynamic voltage restorer(DVR) which serve as an energy buffer and current harmonics blocking resistor connected to sensitive loads, such as, to compensate voltage dips and current harmonics in power distribution system. The DVR is to inject a dynamically controlled voltage generated by a forced commutated converter in series to the bus voltage by means of a booster transformer. The momentary amplitudes of the three injected phase voltages are controlled such as to eliminate any detrimental effects of a bus fault to the load voltage. The proposed system is able to simultaneously compensate current harmonics, voltage fluctuating and voltage unbalance in power distribution systems. The reference phase angle detected by synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The effectiveness of proposed system is verified by the computer simulation.

  • PDF