• 제목/요약/키워드: Voltage Stability Analysis

검색결과 368건 처리시간 0.024초

Enhancement of Interface Flow Limit using Static Synchronous Series Compensators

  • Kim Seul-Ki;Song Hwa-Chang;Lee Byoung-Jun;Kwon Sae-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.313-319
    • /
    • 2006
  • This paper addresses improving the voltage stability limit of interface flow between two different regions in an electric power system using the Static Synchronous Series Compensator (SSSC). The paper presents a power flow analysis model of a SSSC, which is obtained from the injection model of a series voltage source inverter by adding the condition that the SSSC injection voltage is in quadrature with the current of the SSSC-installed transmission line. This model is implemented into the modified continuation power flow (MCPF) to investigate the effect of SSSCs on the interface flow. A methodology for determining the interface flow margin is simply briefed. As a case study, a 771-bus actual system is used to verify that SSSCs enhance the voltage stability limit of interface flow.

SSSC 투입에 따른 연계선로조류의 윤용한계 증대 (A Study on Effects of SSSC Controllers on Interface Flow Limit)

  • 송화창;이병준;권세혁;김슬기
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권2호
    • /
    • pp.83-89
    • /
    • 2001
  • This paper introduces a power flow model of SSSC for voltage stability analysis of power system installed with Static Synchronous Compensators. The SSSC model is obtained from the injection model of voltage source inverter by adding the condition that SSSC injection voltage is in quadrature with current of SSSC-installed branch. This model is incorporated into modified CPF algorithm to study effects of SSSC on the security-constrained interface flow limit. Determination of interface flow limit is simply briefed. In case study a 771-bus real system is used to show that interface flow limit can be improved by appropriate control of SSSC in terms of voltage stability.

  • PDF

STATCOM을 활용한 FIDVR 완화 방안에 대한 연구 (A Study on the FIDVR Mitigation Scheme using Dynamic Voltage Support by STATCOM)

  • 이윤환;정승민
    • 전기학회논문지P
    • /
    • 제67권4호
    • /
    • pp.208-213
    • /
    • 2018
  • In this paper, we studied the control strategy of applying STATCOM(static synchronous compensator) to mitigate the FIDVR(fault induced delayed voltage recovery) phenomenon. The proportion of motor loads is gradually increasing which might affect power system stability. Excessive reactive power consumption by the stall of the motor loads causes FIDVR phenomenon. In addition, the low inertia of the small HVAC(heating, ventilation and air conditioner) unit will not separate itself in the event of a contingency, causing system instability. For this reason, we have developed a control strategy that utilizes STATCOM efficiently through static and dynamic analysis. Case studies on a Korean power system have validated the performance of the proposed scheme under severe contingency scenarios. The results have verified that the proposed strategy can effectively mitigate FIDVR and improve the stability and reliability of the system.

Planning of HVDC System Applied to Korea Electric Power Grid

  • Choi, DongHee;Lee, Soo Hyoung;Son, Gum Tae;Park, Jung-Wook;Baek, Seung-Mook
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.105-113
    • /
    • 2018
  • This paper proposes pre-analysis on planning of high-voltage direct current (HVDC) transmission system applied to Korea electric power grid. HVDC transmission system for interface lines has been considered as alternative solution for high-voltage AC transmission line in South Korea since constructing new high-voltage AC transmission lines is challenging due to political, environmental and social acceptance problems. However, the installation of HVDC transmission system as interface line in AC grid must be examined carefully. Thus, this paper suggests three scenarios to examine the influences of the installation of HVDC transmission system in AC grid. The power flow and contingency analyses are carried out for the proposed scenarios. Power reserves in metro area are also evaluated. And then the transient stability analysis focusing on special protection scheme (SPS) operations is analyzed when critical lines, which are HVDC lines or high voltage AC lines, are tripped. The latest generic model of HVDC system is considered for evaluating the impacts of the SPS operations for introducing HVDC system in the AC grid. The analyses of proposed scenarios are evaluated by electromechanical simulation.

선로저항을 반영하는 에너지함수 유도를 위한 등가시스템 기법의 개발 (The Development of Equivalent System Technique for Deriving an Energy Function Reflecting Transfer Conductances)

  • 문영현;조병훈;노태훈;최병곤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1175-1182
    • /
    • 1999
  • This paper shows that a well-defined energy function can be developed to reflect the transfer conductances for multi-machine power systems under an assumption that all transmission lines have uniform R/X rations. The energy function is derived by introducing a pure reactive equivalent system for the given system. In this study, a static energy function reflecting transfer conductances is also derived as well as the transient energy function. The proposed static energy function is applied to voltage stability analysis and tested for various sample systems. The test results show that the accuracy of voltage stability analysis can be considerable improved by reflecting transfer conductances into the energy function.

  • PDF

STATCOM의 전압안정도개선 및 역률 보상 특성분석 (Characteristic Analysis of Voltage Stability Improvement and Power Factor Correction by STATCOM)

  • 박지용;박덕희;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권12호
    • /
    • pp.1507-1513
    • /
    • 1999
  • This paper describes simulation and experimental results to analyze the dynamic characteristics of STATCOM, which is connected to the ac system for compensation the power factor and improving the voltage stability. The simulation and experimental results confirm that the scaled model for STATCOM can properly compesate the power factor of the load and regulate the bus voltage at the common connection point.

  • PDF

축소모형에 의한 STATCOM의 전압안정도 개선효과 분석 (Improvement Analysis of The Voltage Stability of STATCOM by Scaled Hardware Model Test.)

  • 한병문;김희중;박지용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2079-2081
    • /
    • 1998
  • This paper describes an experimental results to analyze the dynamic characteristics of STATCOM, which is connected to the ac system for improving the voltage stability. The experimental results confirms that the scaled model for STATCOM operates correctly by the conceived control algorithm and properly compensates and regulates the bus voltage at the common connection point.

  • PDF

345[kV] 전력용 변압기 %임피던스 변화에 따른 계통영향 분석 (A Study on the Impact of the Impedance Change of 345[kV] Power Transformers on Overall System Performance)

  • 신정훈;남수철;이재걸;백승묵;송지영;김태균
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.140-149
    • /
    • 2011
  • This paper deals with the impact analysis of the impedance change of 345/154[kV] power transformers on the KEPCO system's overall performance. Through the steady-state and dynamic analysis of power system, the maximum available impedance of power transformers were determined. Checking violation of short-circuit current ratings and transformer overload, parallel operation of power transformers, calculation of voltage variation ratio according to the impedance changes of power transformers are included in the steady-state analysis. In addition, transient and voltage stability analysis are also performed in the study. Available magnitudes to be able to change the impedance of the transformers in KEPCO system are finally determined in the paper.

전압안정도를 고려한 확률론적 도달전력 산정에 관한 연구 (Probabilistic Arrival Power Evaluation considering Voltage Stability)

  • 문승필;장병훈;이재걸;최재석
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1366-1373
    • /
    • 2010
  • Purpose of the electric power system planning and operation is to supply the electric energy to customers continuously and economically. With the mutual exclusive laws of nature between reliability and economic, finding the meeting point is very important but not easy. Commonly the probabilistic reliability indices of the electric power systems are represented with negatively. And the effectiveness of FACTS on the probabilistic reliability could not be reflected with common methods. In this paper, a method to evaluate the probabilistic arrival power at each load point is presented. With this new proposed method, probabilistic reserve margin at load points can be calculated and which can be used with positive reliability index also. Using the P-V analysis, the voltage stability is considered in reliability evaluation. It is expected that the proposed method will be useful expecially in reliability evaluation of electric power system which has voltage restriction.