• 제목/요약/키워드: Voltage Stability Analysis

검색결과 368건 처리시간 0.021초

상용 전압안정도 해석 프로그램 설계 (Design Of practical Voltage Stability Analysis Program)

  • 신만철;오성균;김건중;황인준;박현신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.155-157
    • /
    • 2004
  • Voltage control and stability problems are very important in the electric utility industry. But there is no voltage stability analysis program which has reliability as commercial program in domestic. We are developing a practical voltage stability analysis program. In this paper, we will study the existing commercial program and then discuss design of practical analysis tool.

  • PDF

전압안정도 향상을 위한 FACTS의 적용과 Bifurcation이론 해석 (FACTS Application for the Voltage Stability with the Analysis of Bifurcation Theory)

  • 주기성;김진오
    • 전력전자학회논문지
    • /
    • 제5권4호
    • /
    • pp.394-402
    • /
    • 2000
  • 본 논문온 전압안정도에 Brfurcation 이론을 적용하여 해석하고, FACTS기가인 SVC와 UPFC를 전력계통에 연계하였을 때 전압안정도가 향상되는 효과를 보여주고 있다. 전압안정도는 일반적으로 시스템 파라미터(유효전력 또는 무효전력}를 포행하는 고도의 비선형 동적시스템의 식들에 의해 표현된다. 때때로 전력계통에서의 파라미터 변이는 시스템 불안정을 일으키는 복잡한 동작을 일으킬 수도 있다. 전력계통에서의 FACTS의 연계는 이러한 전압안정도의 범위를 증가시킨다. FACTS를 이용하여 불안정한 HopF Bifurcation과 Saddle Node Bihlfcation을 지연시킴에 의해서 전압안정도기 향상됨을 사례연구를 통하여 입증하였다.

  • PDF

제주계통에서 동기조상기 기동에 따른 전압안정도 영향 검토 (Analysis of Impact on Voltage Stability by Starting Synchronous Condenser in Jeju AC Network)

  • 최순호;이성두;김찬기
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.23-28
    • /
    • 2015
  • Two old synchronous condensers in Jeju are being replaced by new machines to operate Jeju AC network with Haenam-Jeju HVDC system stably. Before new synchronous condensers operate on site, voltage stability analysis is conducted to verify stable operation of jeju AC network. Through impedance analysis of the synchronous machine, transformer and ac network, the equivalent circuit is constructed and the voltage drop during start-up is calculated. Then, PSS/E fault analysis is performed to acquire short-circuit capacity according to the generator operation scenarios. Voltage variation when starting synchronous condenser is simulated in PSCAD/EMTDC and satisfies the operating condition of jeju AC network and HVDC #1 system.

Loss Optimization for Voltage Stability Enhancement Incorporating UPFC Using Particle Swarm Optimization

  • Kowsalya, M.;Ray, K.K.;Kothari, D.P.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.492-498
    • /
    • 2009
  • The placement of the UPFC is the major concern to ensure the full potential of utilization in the transmission network. Voltage stability enhancement with the optimal placement of UPFC using stability index such as modal analysis, Voltage Phasor method is made and the loss minimization including UPFC is formulated as an optimization problem. This paper proposes particle swarm optimization for the exact real power loss minimization including UPFC. The implementation of loss minimization for the optimal location of UPFC was tested with IEEE-14 and IEEE-57 bus system.

EMTP를 이용한 상정사고시의 전압안정도에 관한 연구 (A Study on the Analysis of Voltage Stability on Contingency with EMTP)

  • 송영주;심건보;김정훈;이봉용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.620-622
    • /
    • 1995
  • This paper presents an analysis of the voltage stability when the contingency is occured in the power system. The evaluation of voltage stability is examined by the system identification based on T/L losses and percent indicator which represents how relatively far-off from the voltage collapse. When contingency happens, the bus voltages can be calculated using the EMTP and then, the time-interval in contingency is linearized between the known operating points in nose curves. For the sample study, the 5-bus and 7-bus systems are selected and, countermeasures for the contingency are established in view of the voltage stability.

  • PDF

산업용 전력계통의 주파수 안정도와 전압 안정도를 고려한 부하차단 설계 (A Design of Load Shedding System Considering both Angular Stability and Voltage Stability in Industrial Power System)

  • 김봉희
    • 전기학회논문지P
    • /
    • 제53권3호
    • /
    • pp.103-109
    • /
    • 2004
  • This paper has presented, taking an example of a gas separation plant, dynamic analysis on frequency decline caused by the over-loading at the generator and the knee point causing voltage instability due to reactive power required by re-acceleration of large induction motors, resulting in phenomena of failure in the conventional frequency load shedding. In order to resolve the voltage instability problem, a design of load shedding system employing under-voltage relays has been proposed to the industrial power system containing large induction motors in addition to the conventional load shedding employing frequency relays. For the purpose of dynamic analysis, models of gas turbine and governor, synchronous generator, brushless exciter, and induction motor are introduced.

최적화 조류계산법을 이용한 전압안정도 해석 (Voltage Stability Analysis Using Optimal Load Flow Method)

  • 전동훈;추진부;김건중;이병일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권7호
    • /
    • pp.340-347
    • /
    • 2001
  • In this Paper, we proposed a new voltage stability analysis algorithm. Using $ $ calculated by the optimal load How method(OLF), it rapidly and correctly calculates a PV curve with voltage collapse point in the stable region. OLF can calculates voltage collapse point as well as the operating point in the stable region. Specially, $ $ indicates the relative distance between voltage collapse point and the solution in the unstable region. In the study of a sample system, we verified the superiority of proposed algorithm.

  • PDF

전압안정도를 고려한 경제적인 발전가능전력의 산정알고리즘에 관한 연구 (A Study on Assesment Algorithm for the Economical Generation Capability considering Voltage Stability)

  • 문현호;이종주;윤창대;안비오;최상열;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.536-543
    • /
    • 2006
  • This paper uses Monte Carlo technique, which is one of probabilistic methods of estimating the economical quantity of electric power generation in consideration of voltage stability in the aspect of power generation companies. In the power exchange system in Korea, when power generation companies participate in tenders for power generation capacity at the power exchange, they need to determine their power supply capacity considering the stability of electric power system. Thus, we purposed to propose an algorithm for estimating economical power generation capacity in theaspect of power generation companies, through which we can estimate the margin for voltage stability through P-V curve analysis by capacity according to the change of power generation capacity in a simulated system and to conduct Monte Carlo simulation in consideration of the margin

전압안정도를 고려한 미소신호안정도 해석 (Analysis of Small Signal Stability Considering Voltage Stability)

  • 김동준;문영환;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.323-326
    • /
    • 2001
  • This paper describes the algorithm which can not only take account of voltage suability but also consider small signal stability. As for voltage stability both CPF and PoC methods are utilized to pinpoint the exact voltage collapse point. Then, using the converged load flow results full system matrix is configured and its eigenvalues are computed. The suggested algorithm is applied to the Two-area system, and verified its usefulness. In addition this paper also deals with the results of analyzing the two-area system in terms of voltage stability and small signal stability.

  • PDF

EMTP를 이용한 전압 불안정 현상의 동적 시뮬레이션 (A Dynamic Simulation of Voltage Instability Using EMTP)

  • 허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.295-300
    • /
    • 2003
  • Voltage instability has been studied for some decade now. But, There is not generally accepted definition of voltage instability because of the complex phenomenon and the variety of ways in which it can manifest itself. Both IEEE and CIGRE have the respective definitions. The areas of voltage instability research are the analysis, simulation and countermeasure of voltage instability. It needs to model the components of the power system to simulate the voltage instability and voltage collapse. At the beginning, the static simulation was used. This method provides the voltage stability indices and it requires less CPU resource and gives much insight into the voltage and power problem. However, it is less accurate than the dynamic simulation peformed in the time domain simulation. So, when it appears difficult to secure the voltage stability margin in a static stability, it is necessary to perform the dynamic simulation. To perform time-domain simulation, we have to model the dynamic component of the power system like a generator and a load. The dynamic simulation provides the accurate result of the voltage instability. But, it is not able to provide the sensitivity information or the degree of stability and it is time consuming and it needs much CPU resource. In this Paper, we perform a dynamic simulation of voltage instability and voltage collapse using EMTP MODELS. The exponential load model is designed with MODEIS and this load model is connected with test power system. The result shows the process of voltage change in time domain when the voltage instability or voltage collapse occurs.