• 제목/요약/키워드: Voltage Rising

검색결과 237건 처리시간 0.022초

고속철도 시스템의 레일 전위 상승 해석 (Analysis on Voltage Rise of Rail in High speed Railway System)

  • 이종우
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권8호
    • /
    • pp.481-485
    • /
    • 2003
  • In electric railway system, potential of rail has been risen, for return-current flows through rail. The magnitude of rising voltage is different to railway feed system, ground admittance of rail and the load current. If rising voltage of rail is large, electric shock can be occurred to passengers and maintenance- worker, In this paper, we estimate the rising voltage of rail in high speed railway system and check the safety to human beings.

전철 고상홈 전기통전 위험요인 분석 및 대책 연구 (A study on the Hazard analysis and Improving methods for an Electrical shock on the Platform)

  • 왕종배;조연옥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.258-262
    • /
    • 2004
  • In this paper, the hazard factors on voltage rising effect between the rail and the earth were reviewed in subway system of AC traction line according to moving condition and location of the train. Site measuring of voltage rising between conductor part of train and station floor was performed to ascertain the risk level on the passenger. Plans for preventing hazard of rail-voltage rising and electrical shock on the passengers at platform were proposed.

  • PDF

분포정수회로를 이용한 고전압 급준 펄스 연구 (A Study on the Very Fast Rising High Voltage Pulse Using Distributed Circuit)

  • 곽희로;권동진;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.274-277
    • /
    • 1994
  • This paper describes a very fast rising high voltage pulse generation for studying surge phinomenon and prebreakdown of liquid dielectric by appling the traveling wave theory of the distributed circuit. This very fast rising high voltage pulse generator consists of a charging coaxial cable, a discharging switch, and a terminating resistance. As results, the rising time of pulses are about 31(nsec), which is very fast, and its duration is 950[nsec] when using 200[m] coaxial cable. The length of the coaxial cable and changing voltage can regulate the duration and the amplitude or the polarity of the pulse. When terminated the resistance, capacitor and inductor, the measured waveform corresponds with simulated waveform.

  • PDF

Compact Power-on Reset Circuit Using a Switched Capacitor

  • Seong, Kwang-Su
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.625-631
    • /
    • 2014
  • We propose a compact power-on reset circuit consisting of a switched capacitor, a capacitor, and a Schmitt trigger inverter. A switched capacitor working with a clock signal charges the capacitor. Thus, the voltage across the capacitor is increased toward the supply voltage. The circuit provides a reset pulse until the voltage across the capacitor reaches the high threshold voltage of the Schmitt trigger inverter. The proposed circuit is simple, compact, has no static power consumption, and works for a wide range of power-on rising times. Furthermore, the clock signal is available while the reset pulse is activated. The proposed circuit works for up to 6 s of power-on rising time, and occupies a $60{\times}30{\mu}m^2$ active area.

철도고배 전송선로 분로리액터 설치에 대한 모델링 (A modelling on Shunt Reactors in Railway Power Transmission System)

  • 이종수;이종우
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1262-1268
    • /
    • 2015
  • I In power transmission systems, voltage changes continuously as reactive power is whether over supply or shortage. Reactive power produces in generators and consumes in transmission lines, and loads. Voltages at end points of transmission lines rise which is called Ferranti effect. Excessive voltage rising can reduce transmission equipment life, the voltage rising is usually permitted within the limit of 10%~30% excess. Shunt reactors are installed in transmission lines to put a curb on voltage rising. In this paper, we tried to do modelling for shunt reactor configuration types which are no grounding, grounded and grouded neutral reactor. Simulation are carried out for reactor magnitude for compensating transmission line capacitance.

고속철도 시스템의 레일 전위 상승 해석 (Analysis on Voltage Rise of Rail in High speed Railway System)

  • 명성호;이재복;이종우;이장무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1365-1367
    • /
    • 2000
  • In electric railway system, potential of rail has been risen, for return-current flows through rail. The magnitude of rising voltage is different to railway feed system, ground admittance of rail and the load current. If rising voltage of rail is large, electric shock can be occurred to passengers and maintenance-worker. In this paper, we estimate the rising voltage of rail in high speed railway system and check the safety to human beings.

  • PDF

직류 급전시스템에서의 지락고장에 따른 전압상승 시뮬레이션 (Voltage rising simulation due to the ground fault in DC traction system)

  • 정호성;한문섭;박영;정상기;권삼영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.215-217
    • /
    • 2008
  • DC fraction system can damage human and other facilities due to the rising of rail potential. Therefore the earth fault detection relay protects system using rail potential induced in train operation and ground fault. However the conventional protection system cannot operate due to the fault resistance and might operate unwanted voltage rising due to the other substation ground fault. So this paper models DC traction system using PSCAD/EMTDC and simulates the rail potential rising. We can estimate the rail potential rising in DC traction system through the various simulation.

  • PDF

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

  • Shon, Chae-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.876-883
    • /
    • 2012
  • The paper investigates three types of transfer function methods for detecting displacements of winding in a model transformer. To acquire these transfer functions, the measuring method of input voltage, current and its response is used in impulse method. The applied impulse voltages had three rising times, which were short rising time (less than 0.6 ${\mu}s$), medium rising time (about 0.8 ${\mu}s$) and long rising time (about 1 ${\mu}s$) in front waves. Every 10 measurements of voltage and current waves were averaged from 50 measurements of voltage and current waves. These transfer functions were tested in normal, 24mm elevated and 48mm elevated windings conditions and were analyzed with correlation coefficients and spectrum deviations. In the analysis, the results depend on the types of transfer functions and the rising times of input voltages.

사이리스터의 결함과 항복전압의 관계 분석 (Analysis of the relationship between breakdown voltage and defect of thyristor)

  • 이양재;서길수;김형우;김기현;김상철;김남균;김병철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.149-150
    • /
    • 2005
  • Thyristor breakdown voltage variation acceleration aging test was investigated. The breakdown voltage was deceased after 1000 hours acceleration aging test. It temperature rising caused by electric field concentration at the edge beveling region of the thyristor was confirmed using Silvaco device simulation. The local temperature rising is driving force for the defect propagation. Consequently, propagated defects of the beveling region seems to decrease thyristor's breakdown voltage.

  • PDF

IT기반 분산전원 연계 배전계통의 최적전압조정에 관한 연구 (A study for IT Based Optimal Voltage Control Method of Distribution Systems with Distributed Generation)

  • 김정년;백영식;서규석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권4호
    • /
    • pp.139-143
    • /
    • 2006
  • Recently, standard of living improved and Information-Communication industry developed rapidly. Thereby, interest about electric power quality is rising worldwide. So, research and Development to enhance electric power quality in various viewpoint until most suitable supply system from each kind device to improve electric power quality. And specially, interest about voltage quality is rising by diffusion increase of information communication appliance and minuteness control appliance etc. Also Power consumption is increasing, but expansion of large size generator by environmental and site security problem is difficult. So, introduction of distribution generation is investigated actively by electric-power industry reorganization. Voltage management of power system had been controlled by ULTC (Under Load Tap Changer) in substation and pole transformer on the high voltage distribution line. But, voltage control device on substation and distribution line is applied each other separatively. Therefore, efficiency of line voltage control equipment is dropping. Also, research about introduction upper limit of distribution generation is consisting continuously. This paper presents cooperation use way between voltage control device and introduction upper limit of distribution generation for most suitable voltage control in distribution power system.