• Title/Summary/Keyword: Voltage Rising

Search Result 237, Processing Time 0.032 seconds

The Study on Gate Drive Circuit Design using Single Voltage (단전원 Gate Drive의 회로 설계에 관한 연구)

  • Lee, Sang-Kyun;Lee, Jae-Chon;Lee, Chel-Woong;Lee, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2594-2596
    • /
    • 1999
  • Recently, white good market has interest with inverter product, which has merit to on/off type with respect to energy saving and noise. But, inverter product's cost is rising, because of adding inverter circuit component. To reduce cost, inverter gate drive trend is using HVIC which needs only single voltage. Also using HVIC, designer can compact PCB'size. This paper shows application technique and key point of designing HVIC

  • PDF

A 37.5kV A Class Power Supply for Diagnostic X -ray by High-Frequency Resonant Inverter Type (37.5kVA급 고주파 공진형 인버터식 진단 X선 전원장치)

  • 김학성;유동욱;임근희;완충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.12
    • /
    • pp.113-121
    • /
    • 1996
  • This paper presents a 37.5kVA (125kVp, 300mA) high frequency inverter type power supply for diagonostic X-ray generator with two HFHV (high-frequency high-voltage) isolating transformers. The output regulations, X-ray tuve voltage and tube current, are obtained by two high frequency inverters with the each other feedback PI controller and operating time switch for selecting shooting time and synchronizing two inverters. The operating modes and design consideration of the proposed power supply are given. Issues in the design of two HFHV isolating transformersfors high volage genrating and filament heating are discussed. Experimental results are presented to verify the performance of the designed power supply for varying load conditions. The proposed apparatus has several advnatages, e.g., the fast rising time of tube voltae, accuracy and reduced component size etc.

  • PDF

A Study on the Removal of SOx/NOx by a Pulsed Corona Discharge in the Wire-Plate Reactor (Wire-Plate 반응기에서 펄스 코로나 방전을 이용한 탈황 탈질에 관한 연구)

  • Shin, Wan-Ho;Song, Yong-Hoon;Kim, Han-Seok;Choi, Yeon-Seok;Kim, Seok-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1910-1912
    • /
    • 1996
  • This paper presents the results of laboratory experimentals to remove $SO_2$ and $NO_x$ by a pulsed corona discharge in the wire-plate reactor. A rotating spark gap switch was used to generate the pulse by chewing the dc high voltage. Repetition frequency of the pulse was 60Hz and rising time of 50ns. The photo pictures of positive streamer corona taken by ICCD camera, pulse voltage and current were measured using a digital oscilloscope. Simultaneous effects of $C_{2}H_{4}$ injection and heterogeneous chemical reactions on nonthermal plasma process to remove $SO_2$ and $NO_x$ from flue gas were investigated in the present study

  • PDF

AC/DC Converter Suitable for a Pulsed Mode Switching DC Power Supply (펄스모드 스위칭 직류전원 장치에 적합한 AC/DC 켄버터)

  • Moon S. H.;Nho E. C.;Kim I. D.;Kim H. G.;Chun T. W.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.378-381
    • /
    • 2002
  • This paper describes a novel multilevel ad/dc power converter suitable for the protection of frequent output short-circuit. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. The rising time of the dc load voltage is as small as several hundred microseconds, and there is no overshoot of the do voltage because the dc output capacitors keep undischarged state. Analysis and simulations are carried out to investigate the operation and usefulness of the proposed scheme.

  • PDF

Self-Discharge Effects on Multi-Lamps Backlight Driven by a High Speed Switching Inverter

  • Kwon, Nam-O;Kim, Young-M;Kim, Sung-J;Cho, Tae-Sung;Cho, Guang-Sup;Kim, Bong-Soo;Kang, June-G
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.539-540
    • /
    • 2002
  • A self-discharge in multi-EEFLs and CCFLs has been found to provide a high luminance and efficiency. With a fast rising and falling times of $2{mu}s$, and the peak voltage over 1.6KV, the self-discharge occurs in EEFLs and CCFLs driven by a full bridge switching inverter. Particularly in CCFLs connected with a typical value of ballast capacitance, a self-discharge follows by the main discharge when the voltage falls to the ground.

  • PDF

Pulsed-Power System for Leachate Treatment Applications

  • Jang, Sung-Roc;Ryoo, Hong-Je;Ok, Seung-Bok
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.612-619
    • /
    • 2011
  • This paper presents a water treatment system for leachate from sewage-filled ground that uses a pulsed-power modulator developed based on semiconductor switches in order to realize a long life, a high repetition rate, and a fast rising time. The specifications of the developed pulsed-power modulator are the pulsed output voltage, the output current, the pulse repetition rate (PRR), the pulse width, and an average output power of $60\;kV_{max}$, $300\;A_{max}$, 3000, $50\;{\mu}s$, and 15 kW, respectively. The pulsed-power water treatment system was introduced and analyzed using an equivalent electrical circuit model to optimize the output voltage waveform. The experimental results verify that the proposed water treatment system can be effectively used for industrial applications.

A Study on the New Electrode Structure for the high density Xe realization of AC PDP (AC PDP의 고농도 Xe %실현에 대한 새로운 전극구조에 관한 연구)

  • Kim, G.H.;Lee, D.K.;Lee, Y.K.;Heo, J.E.;Kim, D.H.;Lee, H.J.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1658-1661
    • /
    • 2002
  • Up to now, one of the most serious problems in AC PDP is low luminous efficiency. One possible candidate for solving such problem is using high density Xe. But an increase of the Xe percentage cause rising of the driving voltage and so even if brightness is being increased, luminous efficiency is decreased. In this study, to solve this problem, we proposed new electrode structure. A test panel fabricated using new electrode shows an improvement of efficiency by 25% and a lowering of sustain voltage by 20% compared with the conventioned structure.

  • PDF

A Study on Voltage Variation in KEPCO Distribution System by Introducing the Wind Power Plant (풍력발전단지가 도입되는 한전 실배전계통의 전압변동에 대한 분석)

  • Hwang, J.S.;Jung, W.J.;Kang, S.S.;Kim, B.S.;Kang, H.S.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.16-18
    • /
    • 2001
  • Recently, a study on operation in parallel between Distributed Generation(DG) unit and power distribution system has been growing interest in power distribution system. But, introducing the DG unit causes the problem due to rising the voltage variation on power distribution system. So, This paper presents the effect of introducing DG unit on distribution system. For this simulation, KEPCO distribution system is used.

  • PDF

Directonal Square Pulse Generator construct for Blumlein lain (Blumlein 회로로 구성한 단방향 구형파 펄스 발생기)

  • Kim, Jung-Dal;Chang, Gi-Hyuk;Joo, Sung-Chul;Jung, Jang-Gun;Lee, Duck-Jin;Lee, Yong-Gill
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1779-1781
    • /
    • 1998
  • We are going to design the Square Pulse Generator use of PCPS (Photo-Conductive Power Switch) for Blumlein lain. The circeuit is made of LC device and it is simulated by Schematics Evaluation Version 8.0 of MicroSim. After charged by DC voltage 15[kV]. When the switch is ON, Square pulse is generated after pause time 1.7857[${\mu}s$]. The square pulse is maximum peak voltage 13.987[kV], pulsed width 3.4017[${\mu}s$], rising time 0.7474[${\mu}s$], falling time 1.1718[${\mu}s$].

  • PDF

A study on performance characteristic of Multi-level PDP driver circuit in accordance of signal time (Multi-Level을 사용한 PDP 구동회로에서 Timing 변화에 따른 특성 변화에 관한 연구)

  • Kim, J.S.;Kang, S.E.;Song, S.H.;Roh, J.W.;Hong, S.S.;SaKong, S.C.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.96-98
    • /
    • 2005
  • Proposed Multi-level PDP sustain Driver make use of element which has a low voltage rating instead of suggested method by the existing Webber and it passes through a second phase both rising and falling at sustaining voltage waveform In accordance with the change of timing phase(Tr1, Ti1, Tr2) performance comparison of a electric discharge characteristics in a PDP module has been carried out. At the conclusion of experimentation, the feature is extended by alteration of Ti1 and it has little to do with alteration of Tr1.

  • PDF