• 제목/요약/키워드: Voltage Quality

검색결과 1,545건 처리시간 0.032초

수용가용 30kVA급 IGBT형 STATCOM 개발 (The Development of 30KVA IGBT-type Customer STATCOM)

  • 임수생;이은웅;김종겸;손홍관;조현길;정종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.657-659
    • /
    • 2002
  • Power quality refers to voltage quality and current quality. Voltage quality means supply reliance such as voltage sag, voltage swell. and short-time interruption. Current quality is related to power factor, harmonic distortion, negative-sequence and zero-sequence current. We fabricated Customer STATCOM to improve current quality such as reactive power, harmonic distortion, and load imbalance. In this paper. We summarize the spec, of STATCOM. its hardware configuration, and control system.

  • PDF

Power Flow Control of a Multi-bus/Three-feeder Distribution System Using Generalized Unified Power Quality Conditioner

  • Mohammed, B.S.;Ibrahim, R.;Perumal, N.;Rao, K.S. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.8-17
    • /
    • 2015
  • This paper analyses the power flow of a three-feeder/multi-bus distribution system by a custom Generalized Power Quality Conditioner (GUPQC). The GUPQC has been realized by three voltage source converters (VSCs) coupled back-to-back through a common DC-link capacitor on the DC-side. One feeder was controlled by the shunt compensator, whereas each of the other two feeders was controlled by the proposed novel series compensator. The GUPQC has the capability to simultaneously compensate voltage and current quality problems of a multi-bus/three-feeder distribution system. Besides that, the power can be transferred from one feeder to other feeders to compensate for poor power quality problems. Extensive simulation studies were carried out by using MATLAB/SIMULINK software to establish the ability of the GUPQC to improve power quality of the distribution systems under distorted supply voltage conditions.

Digital-Controlled Single-Phase Unified Power Quality Conditioner for Non-linear and Voltage Sensitive Loads

  • Ryoo Hong-Je;Kim Jong-Soo;Kisck Dragos Ovidiu
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.374-381
    • /
    • 2005
  • The ability to provide quality power has become a significant issue in power systems. The main causes of poor power quality are harmonic currents, poor power factor, supply-voltage variations, etc. A technique of achieving both active current distortion compensation, power factor correction and also mitigating the supply-voltage variation (sag or swell) at the load side is presented in this paper. The operation and rating issues of the proposed Single-phase Unified Power Quality Conditioner are also highlighted. To reduce the total cost while simultaneously increasing the performance, the system is fully digitally controlled using the fixed-point TMS320F240 digital signal processor. The performances of the UPQC, which is composed by shunt and series PWM controlled-converters, have been verified on a laboratory prototype.

부하의 전압특성을 고려한 모선별 전력품질 지표 및 가격 산정기법 (Bus Power Quality Index and Cost based on Load-Voltage Characteristics)

  • 이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.9-14
    • /
    • 2002
  • In front of the opening of electric distribution market in 2004. it is indispensable to have a proper estimation of power quality index and power quality cost calculation mechanism are indispensable to stabilize highly industrialized society and to vitalize the investment for electric power system. However, there were not enough measures to reflect the voltage characteristics such as voltage sags and interruptions which make electric load in unstable operation. This paper suggests power quality index(LDI) and power quality cost(LDC) which translate various kinds of voltage records into load drop index and cost based on aggregated load CBEMA curve. A sample calculation result shows that this method can produces the acceptable power quality index and costs for utilities and customers requirements.

  • PDF

Voltage Sag and Swell Estimation Using ANFIS for Power System Applications

  • Malmurugan, N.;Gopal, Devarajan;Lho, Young Hwan
    • 한국철도학회논문집
    • /
    • 제16권4호
    • /
    • pp.272-277
    • /
    • 2013
  • Power quality is a term that is now extensively used in power systems applications, and in this context the voltage, current, and phase angle are discussed widely. In particular, different algorithms that are capable of detecting the voltage sag and swell information in a real time environment have been proposed and developed. Voltage sag and swell play an important role in determining the stability, quality, and operation of a power system. This paper presents ANFIS (Adaptive Network based Fuzzy Inference System) models with different membership functions to build the voltage shape with the knowledge of known system parameters, and detect voltage sag and swell accurately. The performance of each method has been compared with each other/other methods to determine the effectiveness of the different models, and the results are presented.

Novel Active Voltage Quality Regulator with Adaptive DC-Link Voltage Control

  • Xiao, Guochun;Zeng, Zhong;Liu, Kai;Hu, Zhiliang;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.880-889
    • /
    • 2011
  • In this paper, a novel Active Voltage Quality Regulator (AVQR) topology with a thyristor rectifier and an adaptive dclink voltage control strategy are proposed. The proposed AVQR can efficiently mitigate the long duration variations (e.g. undervoltages/overvoltages), voltage imbalances and voltage harmonics. Compared with conventional AVQRs, it can regulate the load voltage very well with a much lower dc-link voltage. This is accomplished by replacing the diode rectifier with a thyristor rectifier. Moreover, its dc-link voltage can vary with the deviations of the supply voltage through the proposed adaptive dc-link voltage control strategy. All of these contribute to its significantly higher efficiency for online operating, which is very important and attractive for many applications. The proposed topology and control strategy are theoretically analyzed in detail. Simulation results are also provided in the paper. Finally, the feasibility and effectiveness of the proposed method are verified by means of experimental results from a 2kVA prototype. Both of the simulation and experimental results show that the proposed AVQR can achieve a much higher efficiency and similar regulation performance when compared with the conventional ones.

Unified Power Quality Conditioner for Compensating Voltage Interruption

  • Han, Byung-Moon;Cho, Bo-Hyung;Sul, Seung-Ki;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.503-512
    • /
    • 2006
  • This paper proposes a new configuration for the Unified Power Quality Conditioner, which has a DC/DC converter with super-capacitors for energy storage. The proposed UPQC can compensate the reactive power, harmonic current, voltage sag and swell, voltage imbalance, and voltage interruption. The performance of the proposed system was analyzed through simulations with PSCAD/EMTDC software. The feasibility of system implementation is confirmed through experimental works with a prototype. The proposed UPQC has ultimate capability to improve the power quality at the point of installation on power distribution systems and industrial power systems.

고전압트랜스포머의 진공이 방사선출력 노이즈에 미치는 영향 (Electric power characteristic test of diagnostic X-ray high voltage transformer by input power condition)

  • 김영표;천민우;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.499-499
    • /
    • 2008
  • High voltage transformer of Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. High voltage transformer of diagnostic X-ray system has been usefully used for diagnostic purpose but if high voltage transformer performances are deteriorated, low quality image will be archived. In this case, operator has to exposure to get a more good quality images. In this case, unexpected radiation could be exposed to patient and it is very harmful to the patient. And I would like to design and make equipment to checkable high voltage transformer performance after that I wish to test and study what it is most influences in radiation output quality.

  • PDF

Design of DC Side Voltage and Compensation Analysis of THD for Shunt Power Quality Controller under System Load of Rectifier with R-L Load

  • Zhao, Guopeng;Han, Minxiao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.30-40
    • /
    • 2015
  • For a shunt power quality controller (SPQC) the DC side voltage value which is closely related to the compensation performance is a significant parameter. Buy so far, very little discussion has been conducted on this in a quantitative manner by previous publications. In this paper, a method to design the DC side voltage of SPQC is presented according to the compensation performance in the single-phase system and the three-phase system respectively. First, for the reactive current and the harmonic current compensation, a required minimal value of the DC side voltage with a zero total harmonic distortion (THD) of the source current and a unit power factor is obtained for a typical load, through the equivalent circuit analysis and the Fourier Transform analytical expressions. Second, when the DC side voltage of SPQC is lower than the above-obtained minimal value, the quantitative relationship between the DC side voltage and the THD after compensation is also elaborated using the curve diagram. Hardware experimental results verify the design method.

자가 발전 시스템을 갖춘 고전압 전기장 수질개선 장치 개발 (Water Quality Improvement System Using High Voltage Electric Field with Self-Generation System)

  • 강래윤;강철웅
    • 동력기계공학회지
    • /
    • 제19권2호
    • /
    • pp.84-89
    • /
    • 2015
  • The occurrence of algae caused by eutrophication of fresh water is a pollution source to destroy the aquatic environment. When the high voltage electric field is applied in the water, When a high voltage is applied to the electric field in the water, the algae can be broken the balance of cell membranes, and is dead. In this paper, we develop a water quality improvement system for generating an electric field having a higher energy than the zeta potential when a high voltage is applied to 4,000V. To ensure the mobility of the water quality improvement system, we designed the PV generation system using the optimal size technique that is based on the model of power lack ratio. By evaluating the output characteristics of the water quality improvement system, power generation characteristics of the PV generation system, and battery charging characteristics, we can show that the proposed system can be applicable to the water quality improvement system inhibiting the growth rate of the algae in the fresh water.