• 제목/요약/키워드: Voltage Frequency

검색결과 5,126건 처리시간 0.029초

Pb[(Mn1/3Sb2/3)0.05Zr0.475]O3세라믹스를 이용한 변형 Ring/Dot형 압전세라믹 변압기의 감압특성 (Voltage Step-down Characteristics of Modified Ring/Dot-type Piezoelectric Transformer using Pb[(Mn1/3Sb2/3)0.05Zr0.475]O3 Ceramics)

  • 남성진;남효덕;손준호;이준형
    • 한국전기전자재료학회논문지
    • /
    • 제17권2호
    • /
    • pp.171-177
    • /
    • 2004
  • Voltage step-down characteristics in Ring/Dot type piezoelectric transformer were examined as a function of the area of input electrode when the area of output electrode is fixed. The effects of driving frequency and load resistance on the voltage step-down characteristics were also examined. Voltage gain was greatly dependent on the driving frequency and load resistance, and showed a maximum gain at resonance frequency of the step-down transformer. The frequency where the maximum cutout voltage appears increased about 0.2% as the load resistance increased from 10 to 150 Ω. As the area of input electrode increased, the voltage gain and the efficiency of the transformer increased. Frequency dependence of efficiency of the step-down transformer revealed a similar tendency with the voltage gain curves. The maximum efficiency remarked 94% when the input voltage and the load resistance were 20 Vpp and 120 Ω, respectively.

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF

저주파 변압기를 이용한 구형파 증폭시스템 (The design of high-voltage rectangular waveform generator)

  • 이복희;최원규;임정규;이병원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2152-2154
    • /
    • 1999
  • In this paper, we suggested the design rule of high-voltage rectangular waveform generator working in low frequency domain (5Hz $\sim$ 60Hz). Most of the commonly used power electronic switching devices have voltage ratings up to several kV. So it is difficult to design and fabricate high-voltage switching systems with the power electronic devices alone. We have combined IGBTC(1200V, 50A) with the specially designed transformer to get the high-voltage rectangular waveforms up to 40kV. In this work. next two things are the main factors. The first one is design of transformer working low-frequency domain close to 5Hz. And the second one is additional voltage source to floating the transformer voltage output. As a result, we can get frequency-variable and high-voltage rectangular voltage waveform and this can be a more efficient power source of sandpaper manufacturing process.

  • PDF

입력파형에 따른 PZT 바이몰프 진동자의 출력특성 (The output characteristics of the input waveform to the PZT bimorph vibrator)

  • 김용혁;추순남
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.1-5
    • /
    • 2013
  • The aim of this study is to research maximum harvesting energy by the optimal input wave condition. The voltage characteristics of the PZT bimorph were investigated in terms of the sine wave, triangle wave and square wave according to frequency range 0~70Hz. It was found that the square wave compared with a triangular wave or square wave was showed the higher output energy. PZT bimorph was mechanically vibrated by solenoid coil experiments, which revealed two voltage peak mode according to frequency. Maximum voltage at second vibration frequency 28Hz demonstrated that the generated DC voltage was proportional to the tip displacement of the bimorph and the phase difference between the input frequency and bimorph vibration frequency was 90 degree. It was expected that optimized design to harvest a much higher energy level from lower frequency vibrations.

Design of a Frequency Locked Loop Circuit

  • Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제6권3호
    • /
    • pp.275-278
    • /
    • 2008
  • In this paper, I propose the full CMOS FLL(frequency locked loop) circuit. The proposed FLL circuit has a simple structure which contains a FVC(frequency-to-voltage converter), an operational amplifier and a VCO(voltage controlled oscillator). The operation of FLL circuit is based on frequency comparison by the two FVC circuit blocks. The locking time of FLL is short compared to PLL(phase locked loop) circuit because the output signal of FLL is synchronized only in frequency. The circuit is designed by 0.35${\mu}m$ process and simulation carried out with HSPICE. Simulation results are shown to illustrate the performance of the proposed FLL circuit.

Effects of Phase Difference between Voltage loaves Applied to Primary and Secondary Electrodes in Dual Radio Frequency Plasma Chamber

  • Kim, Heon-Chang
    • 반도체디스플레이기술학회지
    • /
    • 제4권2호
    • /
    • pp.11-14
    • /
    • 2005
  • In plasma processing reactors, it is common practice to control plasma density and ion bombardment energy by manipulating excitation voltage and frequency. In this paper, a dually excited capacitively coupled rf plasma reactor is self-consistently simulated with a three moment model. Effects of phase differences between primary and secondary voltage waves, simultaneously modulated at various combinations of commensurate frequencies, on plasma properties are investigated. The simulation results show that plasma potential and density as well as primary self-dc bias are nearly unaffected by the phase lag between the primary and the secondary voltage waves. The results also show that, with the secondary frequency substantially lower than the primary frequency, secondary self·do bias remains constant regardless of the phase lag. As the secondary frequency approaches to the primary frequency, however, the secondary self-dc bias becomes greatly altered by the phase lag, and so does the ion bombardment energy at the secondary electrode. These results demonstrate that ion bombardment energy can be more carefully controlled through plasma simulation.

  • PDF

Three-Phase AC-to-DC Resonant Converter Operating in High Power Factor Mode in High-Voltage Applications

  • Chaudhari, Madhuri A.;Suryawanshi, Hiralal M.;Kulwal, Abhishek;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.60-73
    • /
    • 2008
  • In this paper a three-phase ac-to-dc resonant converter with high input power factor and isolated output is proposed. To improve the input power factor of the converter, high frequency current is injected into the input of the three-phase diode bridge rectifier. It is injected through an impedance network consisting of a series of L-C branches from the output of the high frequency three-phase inverter. A narrow switching frequency variation is required to regulate the output voltage. A design example with different design curves is illustrated along with the component ratings. Experimental verification of the converter is performed on a prototype of 3 kW, 1000 V output, operating above 300 kHz. Experimental results confirm the concept of the proposed converter. Narrow switching frequency variation is required to regulate the output voltage.

권선형 유도 발전기 CVCF 발전을 위한 2차 여자 제어법에 관한 연구 (A Study on the 2nd exitation method for CVCF Generation of doubly-fed induction Generator)

  • 안진우;김철우;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.341-344
    • /
    • 1988
  • This paper derives a condition foe constant voltage i constant frequency generation of doubly-fed induction generator. The condition is varied by the magnitude of output voltage, load current and its power factor, slip of the machine. Magnitude of output voltage is controlled by exiting voltage which is caculated by derived equation from operating condition. frequency of output voltage is controlled by injecting slip frequency to the rotor which is the difference between wanted output frequency and rotor frequency.

  • PDF

가변전압 가변주파수(VVVF) 교류 플라즈마 전원장치 (AC Plasma Power Supply with Variable Voltage and Variable Frequency)

  • 신완호;윤기복;정환명;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1205-1207
    • /
    • 2004
  • AC plasma power supply is used to control a ozone generator and a air pollution gas. AC plasma power supply is composed of power semiconductor switch devices and control board adapted SHE(Selected Harmonic Elimination) PWM method. AC plasma power supply with sinusoidal VVVF(variable voltage and variable frequency) is realized. Its output voltage range is from 0 [V] to 20[kV] and output frequency range is from 8[kHz] to 20[kHz]. Using proposed system, AC high voltage and high frequency discharge is tested in the DBD(dieletric barrier discharge) reactor, and the space distribution of a its non-thermal plasma is observed. In spite of the increasement of voltage and frequency, the proposed system have a stable operation characteristics. It is verified by the experimental results.

  • PDF

Analysis and design of voltage doubling rectifier circuit for power supply of neutron source device towards BNCT

  • Rixin Wang;Lizhen Liang;Congguo Gong;Longyang Wang;Jun Tao
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2395-2403
    • /
    • 2024
  • With the rapid development of DC high voltage accelerator, higher requirements have been raised for the design of DC high voltage power supply, requiring more stable high voltage with lower output ripple. Therefore, it also puts forward higher requirements for the parameter design of the voltage doubling rectifier circuit, which is the core component of the DC high voltage power supply. In order to obtain output voltage with better performance, the effects of the working frequency, the stage capacitance and the load resistance on the output voltage of the voltage doubling rectifier circuit are studied in detail by simulation. It can be concluded that the higher the working frequency of the transformer, the larger the stage capacitance, the larger the load resistance and the better the output voltage performance in a certain range. Based on this, a 2.5 MV voltage doubling rectifier circuit driven by a 120 kHz frequency transformer is designed, developed and tested for the power supply of the neutron source device towards BNCT. Experimental results show that this voltage doubling rectifier circuit can satisfy the design requirements, laying a certain foundation for the engineering design of DC high voltage power supply of neutron source device.