• 제목/요약/키워드: Voltage Control Area

검색결과 301건 처리시간 0.029초

Training an Artificial Neural Network (ANN) to Control the Tap Changer of Parallel Transformers for a Closed Primary Bus

  • Sedaghati, Alireza
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1042-1047
    • /
    • 2004
  • Voltage control is an essential part of the electric energy transmission and distribution system to maintain proper voltage limit at the consumer's terminal. Besides the generating units that provide the basic voltage control, there are many additional voltage-controlling agents e.g., shunt capacitors, shunt reactors, static VAr compensators, regulating transformers mentioned in [1], [2]. The most popular one, among all those agents for controlling voltage levels at the distribution and transmission system, is the on-load tap changer transformer. It serves two functions-energy transformation in different voltage levels and the voltage control. Artificial Neural Network (ANN) has been realized as a convenient tool that can be used in controlling the on load tap changer in the distribution transformers. Usage of the ANN in this area needs suitable training and testing data for performance analysis before the practical application. This paper briefly describes a procedure of processing the data to train an Artificial Neural Network (ANN) to control the tap changer operating decision of parallel transformers for a closed primary bus. The data set are used to train a two layer ANN using three different neural net learning algorithms, namely, Standard Backpropagation [3], Bayesian Regularization [4] and Scaled Conjugate Gradient [5]. The experimental results are presented including performance analysis.

  • PDF

배전 선로에 연계된 다수대의 변동성 재생에너지 발전 시스템의 출력 유효전력 변동에 따른 무효전력 제어를 이용한 전압 변동 보상 (Compensation of Voltage Variation Using Active Power-Dependent Reactive Power Control with Multiple VRE Systems Connected in a Distribution Line)

  • 이상훈;김수빈;송승호
    • 풍력에너지저널
    • /
    • 제9권4호
    • /
    • pp.47-56
    • /
    • 2018
  • This paper introduces an active power dependent standard characteristic curve, Q(P) to compensate for voltage variations due to the output of distributed generation. This paper presents an efficient control method of grid-connected inverters by comparing and analyzing voltage variation magnitude and line loss according to the compensation method. Voltage variations are caused not only by active power, but also by the change of reactive power flowing in the line. In particular, the system is in a relatively remote place in a coastal area compared with existing power plants, so it is relatively weak and may not be suitable for voltage control. So, since it is very important to keep the voltage below the normal voltage limit within the specified inverter capacity and to minimize line loss due to the reactive power. we describe the active power dependent standard characteristic curve, Q(P) method and verify the magnitude of voltage variation by simulation. Finally, the characteristics of each control method and line loss are compared and analyzed.

과변조 영역에서의 전류제어를 가지는 영구자석형 동기 전동기의 속도제어 (Speed Control of PMSM with Current Controller in Overmodulation Region)

  • 박진식;김학원;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.251-253
    • /
    • 2005
  • This paper presents a study on a current control of a PM synchronous motor which is fed by two-level voltage source inverter in the high modulation index area. In order to increase dynamic response and extend speed limit caused by voltage limit, overmodulation method is generally used. The current control in overmodulation have voltage limit. So larger voltage command than voltage limit should be diminished. In this paper, the problem conventional normalization method is analyzed and New normalization method in overmodulation region is proposed.

  • PDF

강인 제어에 의한 Static Synchronous Series Compensator의 전력계통 동요 억제 (Damping Oscillation of Power System by Robust Control of SSSC)

  • 김학만;오태규;국경수;전진홍;장병훈;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1035-1038
    • /
    • 1999
  • To improve the damping of all poorly damped oscillation modes, a control strategy of Static Synchronous Series Compensator (SSSC) based on energy method is presented in this Paper As a synchronous voltage-sourced inverter, SSSC is used to provide controllable series compensation. SSSC can provide controllable compensating voltage over an identical capacitive and inductive range. The damping effect of control strategy based on energy function is robustness with respect to loading condition, fault location and network configuration. Furthermore, the control inputs are based on local signals. In two area system, the effect of damping inter-area mode oscillation is demonstrated by the robust control strategy of SSSC.

  • PDF

Area of Severity 평가를 이용한 에너지 저장장치의 위치 결정에 관한 연구 (A study on the Placement of Energy Storage System by using Area of Severity Assessment)

  • 이계병;박창현;배종일;이한상;조수환;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.321-322
    • /
    • 2015
  • An area of severity (AOS) assessment is defined as a set of the fault positions that can result in the voltage sag bigger than certain level for sensitive buses simultaneously. Using the AOS assessment, the location of devices for compensating voltage sag can be determined as the site expected to less voltage sag at the sensitive bus. The energy storage system based on the control strategy emulating the traditional synchronous generator can contribute the fault current with fast response. Therefor are of venerability (AOV) can be reduced. The energy storage system installed by the AOS assessment has function which can experience relatively less voltage sag in addition to the conventional role of energy storage.

  • PDF

A Novel Seamless Direct Torque Control for Electric Drive Vehicles

  • Ghaderi, Ahmad;Umeno, Takaji;Amano, Yasushi;Masaru, Sugai
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.449-455
    • /
    • 2011
  • Electric drive vehicles (EDV) have received much attention recently because of their environmental and energy benefits. In an EDV, the motor drive system directly influences the performance of the propulsion system. However, the available DC voltage is limited, which limits the maximum speed of the motors. At high speeds, the inverter voltage increases if the square wave (SW) voltage (six-step operation) is used. Although conventional direct torque control (DTC) has several advantages, it cannot work in the six-step mode required in high-speed applications. In this paper, a single-mode seamless DTC for AC motors is proposed. In this scheme, the trajectory of the reference flux changes continuously between circular and hexagonal paths. Therefore, the armature voltage changes smoothly from a high-frequency switching pattern to a square wave pattern without torque discontinuity. In addition, because multi-mode controllers are not used, implementation is more straightforward. Simulation results show the voltage pattern changes smoothly when the motor speed changes, and consequently, torque control without torque discontinuity is possible in the field weakening area even with a six-step voltage pattern.

연료 부족에 의한 고분자전해질형 연료전지의 역전압 성능 (PEMFC performance on reverse voltage by fuel starvation)

  • 이흥주;송현도;김준범
    • 한국수소및신에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.133-140
    • /
    • 2006
  • The performance of proton exchange membrane fuel cell was decreased by reverse voltage using fuel starvation. Performance decrease in local area could be affected by duration and extent of reverse voltage. Hydrogen and air stoichiometic ratio was used to find the experimental condition of abrupt voltage decrease. LabVIEW was used to make control logic of automatic load off system in preset voltage. Reverse voltage experiment was done down to -1.2 V at constant current condition. When fuel cell voltage was reached to preset voltage, electronic load was disconnected to make open circuit voltage for 1 minute. Fuel cell performance was checked every 5 cycle and the degree of performance decrease and/or recovery was estimated. Ohmic resistance and charge transfer resistance were increased and platinum surface area was reduced 41% after reverse voltage experiment.

An Adaptive Undervoltage Load Shedding Against Voltage Collapse Based Power Transfer Stability Index

  • Nizam, Muhammad;Mohamed, Azah;Hussain, Aini
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.420-427
    • /
    • 2007
  • This paper highlights the comparison of a proposed methods named adaptive undervoltage load shedding based PTSI techniques for undervoltage load shedding and two previous methods named Fixed Shed Fixed Delay (FSFD) and Variable Shed Variable Delay (VSVD) for avoiding voltage collapse. There are three main area considerations in load shedding schemes as the amount of load to be shed, the timing of load shedding event, and the location where load shed is to be shed. The proposed method, named as adaptive UVLS based PTSI seem to be most appropriate among the uncoordinated schemes. From the simulation result can be shown the Adaptive UVLS based PTSI give faster response, accurate and very sensitive control for the UVLS control technique. This technique is effectively when calculating the amount to be shed. Therefore, it is possible to bring the voltage to the threshold value in one step. Thus, the adaptive load shedding can effectively reduce the computational time for control strategy.

Low-Cost SVM-DTC Strategy of Induction Machine Drives Using Single DC-link Current Sensor

  • Wang, Wei;Cheng, Ming;Hua, Wei;Ding, Shichuan;Zhu, Ying;Zhao, Wenxiang
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.266-273
    • /
    • 2012
  • In conventional direct torque control (DTC) using space-vector modulation (SVM) of induction machine (IM) drives, at least three current sensors are needed. In this paper, a low-cost SVM-DTC strategy is proposed, in which only a single current sensor is used. The position of the voltage space vector is divided into two areas: effective and non-effective area. If it is located in the non-effective area, the voltage space vector will be shifted into the effective area with minimum distortion. Further, the switching frequency remains constant. The simulation is carried out on a MATLAB/Simulink platform and the simulated results verify the effectiveness of the proposed strategy.

유도전동기의 전압·전류 모델 합성 자속 추정기에 의한 속도제어에 관한 연구 (A Study on Speed Control by means of voltage·current model complex flux estimator)

  • 황락훈;나승권;최성식
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5416-5426
    • /
    • 2012
  • 본 논문에서는 유도전동기의 저속운전영역에서 고속운전영역에 이르기까지 모든 영역에 걸친 안정된 속도제어를 목적으로 전압 전류 모델 합성 자속 추정기를 통해 저속영역에서와 고속영역에서 각각 다른 모델에 의한 자속을 추정하고 이로부터 자속각을 추정하는 알고리즘을 사용한다. 특히 저속영역에서 부하가변시의 전류의 변화와 자속의 변화를 실시간으로 추정하여 저속영역에서의 제어특성을 향상시켜 부하 가변 시에도 전 영역에서 보다 안정된 비례적분 전류 제어기, 비례적분자속 제어기에 의한 시뮬레이션 및 실험을 실시한 결과 우수한 속도제어특성을 얻을 수 있었다.