• 제목/요약/키워드: Voltage Application Time

검색결과 431건 처리시간 0.026초

배전계통에 초전도한류기 적용시 전압요소를 이용한 과전류계전기 정정 연구 (Study on the OCR Setting Using the Voltage Component Considering Application of the SFCL in a Power Distribution System)

  • 임승택;임성훈
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1587-1594
    • /
    • 2018
  • In south korea, the government make a plan to generate the 20% of the total electrical power as renewable source like wind generation and solar generation. This plan will accelerate the increase of fault current with power industry's growth. As the increase of fault current, the superconducting fault current limiter (SFCL) has been studied. In case that the SFCL is applied in power system, it can cause the overcurrent relay (OCR)'s trip delay because of the reduced fault current. In this paper, the overcurrent relay with voltage component was suggested to improve the OCR's trip delay caused by the SFCL and compensational constant was introduced to have the trip time similar to the trip time of case without the SFCL. For conforming the effect of the suggested OCR with voltage component, the PSCAD/EMTDC simulation modeling and analysis were conducted. Through the simulation, it was conformed that the trip delay could be improved by using the suggested OCR and compensational constant.

진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가 (The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application)

  • 박지군;이미현;최영준;정봉재;최일홍;강상식
    • 한국방사선학회논문지
    • /
    • 제4권2호
    • /
    • pp.21-25
    • /
    • 2010
  • 최근 진단 X선 검출기 적용을 위한 방사선 검출물질로 반도체 화합물에 대한 많은 연구가 되고 있다. 본 연구에서는 반도체 화합물 중 광민감도가 우수하고 X선 흡수율이 높은 CdS 반도체를 이용하여 검출센서를 제작하였으며, 진단 X선 발생장치에서의 에너지 영역에 대한 검출 특성을 조사함으로써 적용 가능성을 평가하였다. 센서 제작은 CdS 센서로부터의 신호 획득 및 정량화를 위한 Line voltage selector(LCV)를 제작하였으며, 전압감지회로 및 정류회로부를 설계 제작하였다. 또한 X선 노출조건에 따른 상호연과 알고리즘을 이용하였으면, DAC 컨트롤러와의 Interface board를 설계 제작하였다. 성능평가는 X선 발생장치의 조사조건인 관전압, 관전류 및 조사시간별 저항변화에 따른 전압파형 특성을 오실로스코프로 획득하여 ANOVA 프로그램을 이용하여 데이터를 통계 처리 및 분석하였다. 측정결과, 관전압과 관전류이 증가할수록 오차의 비가 감소하였으며, 90kVp에서 6%, 320 mA에서 0.4% 이하의 좋은 특성을 보였으며, 결정계수는 약 0.98로 1:1의 상관관계를 보였다. X선 조사시간에 따른 오차율은 CdS 물질의 늦은 반응속도에 기인하여 조사시간이 길어질수록 지수적으로 감소하는 것을 알 수 있었으며, 320 msec에서 2.3%의 오차율을 보였다. 끝으로 X선 선량에 따른 오차율은 약 10% 이하였으며, 0.9898의 결정계수로 매우 높은 상관관계를 보였다.

Re-ignition System using Vacuum Triggered Gap-switch for Synthetic Breaking Test

  • Park Seung-Jae;Suh Yoon-Taek;Kim Dae-Won;Kim Maeng-Hyun;Song Won-Pyo;Koh Hee-Seog
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권4호
    • /
    • pp.145-151
    • /
    • 2005
  • The synthetic breaking test method was developed to evaluate the breaking performance of ultra high-voltage circuit breaker and made up of two independent circuits; current source circuit and voltage source circuit. In application of this test method, it is necessary to extend the arc of the test breaker. So, the new re-ignition system using VTGS (Vacuum Triggered Gap-Switch) was constructed to improve the efficiency and reliability of this test. In this re-ignition system, VTGS operates in high vacuum state of $5{\time}10^{17}$torr and control system consists of the triggering device and the air M-G (Motor-Generator). This re-ignition system showed the operating characteristics, such as delay time ($t_d$) and jitter time ($t_j$ not exceeding 5us and 1us respectively, and had the operating voltage of $25\~150kVdc$ at the gap distance of 24mm.

하드애노디제이션에 의한 나노다공질 양극산화 알루미나 멤브레인의 제조 (Fast Fabrication of Nanoporous Anodic Alumina Membrane by Hard Anodization)

  • 하윤철;정대영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.429-429
    • /
    • 2009
  • Nanoporous anodic alumina membranes (NAAM) with high-density through-hole pores fabricated by hard anodization of aluminum in 0.3 M oxalic acid under the applied voltage of 40 (mild anodization), 80, 100, 120 and 140 V were investigated. The current-time responses monitored using a PC-controlled anodization cell and the corresponding pore structures attainable from field-enhanced scanning electron microscopy (FE-SEM) were analyzed in order to establish the optimum fabrication process. The nanoporous structure can be produced for all the voltage conditions, while the stabilized through-hole pore formation seems to occur at 40, 80 and 140 V. The growth rate under 140 V hard anodization was over 30 times higher than under 40 V mild anodization (1.5 um/hr).

  • PDF

APPLICATION OF SOUND INTENSITY METHOD TO NOISE CONTROL ENGINEERING AND BUILDING ACOUSTICS

  • Tachibana, Hideki
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 추계학술대회논문집; 한국종합전시장, 24 Nov. 1995
    • /
    • pp.7-15
    • /
    • 1995
  • Sound pressure and particle velocity are the most essential quantities prescribing a sound field; they correspond to voltage and electric current respectively, in electric system. As electric power is the product of voltage and electric current, sound intensity is the product of sound pressure and particle velocity and it means the acoustic power passing through a unit area in a sound field. Although the definition of sound intensity is very simple as mentioned above, the method of measuring this quantity has not been realized for a long time, because it has been very difficult to measure the particle velocity simultaneously with the sound pressure. Owing to the recent development of such technologies as transducer production and digital signal processing, it has finally been realized. According to the sound intensity(SI) method, the sound power flow in an arbitrary sound field can be directly measured as a vector quantify. In this paper, the principle of the SI method is briefly explained at first and some examples of its application made in the author's laboratory are introduced.

  • PDF

전력 변환 손실 저감을 위한 하이브리드 주거배전시스템 (A Study on Residential Hybrid Distribution System for Reducing Power Conversion Loss)

  • 변병주;서현욱;최중묵;이영진;최규하
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.413-421
    • /
    • 2013
  • This paper proposes residential hybrid distribution system that can supply AC power and DC power to AC load and DC load at the same time. This hybrid distribution system consists of three parts: bidirectional inverter, step-up converter and step-down converter. Also that is used to supply voltage to home application is classified of AC load and DC load as load characteristics. The performance of proposed hybrid distribution system is validated through the hardware implementation and the experimental results.

A New Modularized Balancing Circuit for Series Connected Battery cells

  • Lee, Hyo-Jae;Jung, Young-Seok
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.193-199
    • /
    • 2014
  • The series connected battery cells are mainly used in high voltage battery pack application. However parameter inequality of each battery cell makes battery voltage imbalance problem. In this paper, a new balancing circuit utilizing converter scheme for the series connected battery cells is proposed. Proposed circuit offers easy control and fast equalization time. Moreover the circuit can be used in a practical application because it has high modularity and can operate during the charging/discharging cycle. To show its superiorness and effectiveness, the principle of proposed circuit is explained with computer simulation and experiment is carried out using lithium-ion battery.

Effect of form of applied current on the formation behavior of PEO films on Al6082 alloy

  • Moon, Sungmo;Kim, Juseok;Shin, Heon-Cheol
    • 한국표면공학회지
    • /
    • 제55권1호
    • /
    • pp.9-17
    • /
    • 2022
  • This work is concerned with the formation behavior of PEO (Plasma Electrolytic Oxidation) films on Al6082 alloy under the application of direct current (DC) and alternating current (AC) in an alkaline solution. Arc initiation voltage became much lower by the application of AC than DC, and arc initiation time became shorter under DC than AC. The number of pores present in the PEO films was much larger than that on the surface, irrespective of DC and AC. It was also found that the number of pores in the PEO films formed under AC was more than that under DC and the size of pores is smaller under AC than DC. During the formation of PEO films, a lot of heat was generated and solution temperature increased more rapidly under DC than under AC which is attributed to high PEO film formation voltage under DC than AC.

A Low Power, Small Area Cyclic Time-to-Digital Converter in All-Digital PLL for DVB-S2 Application

  • Kim, Hongjin;Kim, SoYoung;Lee, Kang-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권2호
    • /
    • pp.145-151
    • /
    • 2013
  • In this paper, a low power, small area cyclic time-to-digital converter in All-Digital PLL for DVB-S2 application is presented. Coarse and fine TDC stages in the two-step TDC are shared to reduce the area and the current consumption maintaining the resolution since the area of the TDC is dominant in the ADPLL. It is implemented in a 0.13 ${\mu}m$ CMOS process with a die area of 0.12 $mm^2$. The power consumption is 2.4 mW at a 1.2 V supply voltage. Furthermore, the resolution and input frequency of the TDC are 5 ps and 25 MHz, respectively.

Effects of pH Early Postmortem on Meat Quality in Beef Longissimus

  • Hwang, I.H.;Tompson, J.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권8호
    • /
    • pp.1218-1223
    • /
    • 2003
  • The effects of type (high and low voltages) and time (3, 40 and 60 min postmortem) of stimulation on drip loss and meat color at 24 h post-mortem were determined on M. longissimus dorsi of 38 crossbred steers and heifers. In addition, the effect of pH early postmortem (70 min postmortem) on the rate and extend of meat tenderization was examined. Either high or low voltage stimulation at 3 min showed a tendency for faster pH decline (p=0.052) and higher drip loss (p=0.08), and improved the color dimensions of L*, a* and b* (p<0.01), compared to stimulation at 40 min. This was equivalent to approximately one unit of an AUSMEAT color chip. On the other hand, although there were significant differences in pH decline between high voltage stimulation at 40 and 60 min, and between low voltage stimulation at 40 min and control sides, drip loss and meat color did not differ significantly (p>0.05). The results suggested that early application of stimulation, regardless of type of stimulation, improved overall meat color at 24 h postmortem through its effect on faster glycolysing rate. However, if the pH decline was moderate, the benefit of electrical stimulation on meat color was not apparent. An intermediate pH decline resulted in the lowest shear force. Due to differential ageing rates the optimum pH at 70 min postmortem increased with ageing time from 5.96, 6.07, 6.12 and 6.14 for 1, 3, 7 and 14 days postmortem, respectively. This implied that a small difference in the rate of pH decline was important, especially carcasses stimulated for very early postmortem, and the optimum rate of pH decline varied with intended ageing period. The study suggests that the beneficial or adverse effects of electrical stimulation on drip loss, meat color and tenderness is determined by the rate of pH decline, rather than by stimulation treatment and time of application per se.