• Title/Summary/Keyword: Voltage Application Time

Search Result 431, Processing Time 0.03 seconds

Design of Snubber Capacitor for Equalization of Voltage Sharing in Series Connected SiC MOSFETs

  • Min, Juhwa;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.188-189
    • /
    • 2017
  • There has been a growing demand for power semiconductor switches equipped with high-voltage blocking capability of kV range and fast-switching characteristics of ns range in various plasma application. This paper investigates the application of SiC MOSFETs in the particular plasma application which requires the blocking voltage of 4.5kV and the switching transient time of less than 100ns. In order to meet the required blocking voltage, the series connection of multiple SiC MOSFETs is adopted in this paper. Also, snubber capacitors are employed to equalize the voltage sharing among the series connected SiC MOSFETs. The simulation and experimental result successfully verifies the application of SiC MOSFETs and snubber capacitors in the plasma application requiring high-voltage and fast-switching load dynamics.

  • PDF

Electroluminescent Characteristics of Fluorescent OLED with Alternating Current Negative Voltage (교류 음 전압에 따른 형광 OLED의 전계 발광 특성)

  • Seo, Jung-Hyun;Yang, Jae-Woong;Paek, Kyeong-Kap;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.2
    • /
    • pp.72-77
    • /
    • 2019
  • To study the characteristics of AC driven OLED, we fabricated the fluorescent OLEDs and analyzed the electroluminescence characteristics of OLEDs with AC negative voltage. The luminance and the current density of the OLED decreased, and the number and size of the dark spots increased in proportion to the duration time and level of the applied AC negative voltage. The current efficiency of the OLED was improved when high AC negative voltage was applied within a short time. When the AC negative voltage of 10 V was applied for 1 minute, the efficiency was improved by 12.4%. Also, the degradation of luminance and current efficiency due to the duration of light emission was improved in the case of OLED applied for 1 minute with 10 V AC negative voltage. These are expected as a result of the improvement of the leakage current characteristics by eliminating the short-circuit region formed by the defect of the OLED at the AC negative high voltage. As a result, the continuous application of AC negative voltage reduced the luminance and the current density of OLED, but the temporary application of AC negative voltage with the proper time and voltage could improve the efficiency and lifetime of OLED.

Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator (가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출)

  • Kim, Sanggu;Kim, Minsung;Yoo, Shinjung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2018
  • The study figured out the operational conditions of a two-way movement actuator made of one-way shape memory alloy (OWSMA) for versatile ventilation intelligent garments. To develop a low-power actuator that consumes energy only when a garment changes its form such as opening and closing, multiple channels of OWSMA were used, and optimum diameter of the wires was examined. For the switch device, optimum voltage application unit time was determined. Optimum diameter of OWSMA wire was determined by applying 3.7V to the pre-determined candidate diameters, which demonstrated two-way operation in previous studies. In order to evaluate the optimum voltage application time, the internal diameter of the actuator was measured while increasing and decreasing by 50 ms from the unit time of voltage application. Delay time under two-way operation of the actuator was measured to minimize interference caused by heat between channels. Power of 3.7V was applied to OWSMA for assessment of optimal time, and the whole process from heating to cooling was video-recorded with a thermal image camera to determine the point of time at which the temperature of OWSMA wire dropped below the phase transformation temperature. The results showed that $0.4{\Phi}$ was the most suitable diameter, and the optimum unit time of voltage applied to open and close the actuator was 4100ms. It was also shown that the delay time should be more than 1.8 seconds between two-way operations of the actuator.

Analysis of Voltage Stress in Stator Windings of IGBT PWM Inverter-Fed Induction Motor Systems

  • Hwang Don-Ha;Lee Ki-Chang;Jeon Jeong-Woo;Kim Yong-Joo;Lee In-Woo;Kim Dong-Hee
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.43-49
    • /
    • 2005
  • The high rate of voltage rise (dv/dt) in motor terminals caused by high-frequency switching and impedance mismatches between inverter and motor are known as the primary causes of irregular voltage distributions and insulation breakdowns on stator windings in IGBT PWM inverter-driven induction motors. In this paper, voltage distributions in the stator windings of an induction motor driven by an IGBT PWM inverter are studied. To analyze the irregular voltages of stator windings, high frequency parameters are derived from the finite element (FE) analysis of stator slots. An equivalent circuit composed of distributed capacitances, inductance, and resistance is derived from these parameters. This equivalent circuit is then used for simulation in order to predict the voltage distributions among the turns and coils. The effects of various rising times in motor terminal voltages and cable lengths on the stator voltage distribution are also presented. For a comparison with simulations, an induction motor with taps in the stator turns was made and driven by a variable-rising time switching surge generator. The test results are shown.

CIM-Based System For Real-Time Voltage Stability Analysis (CIM 기반의 실시간 전압안정도 해석 시스템 구축)

  • Lee, Sung-Woo;Jang, Moon-Jong;Seo, Dong-Wan;Namkoong, Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.41-49
    • /
    • 2013
  • There is a wide variety of system and applications in the power system. However, they have compatibility issues because they use different data standard and communication method. With the introduction of the smart grid, power system has been grow and diversified. Therefore power system need to be compatible with each other and the interoperability between applications is increasingly important. Thus, the IEC established IEC61970 and CIM Standard data exchange model for interoperability and system integration. Server-Client system was constructed which using CIM HSDA(Part4), a standard communication model, presented in IEC 619710. Also, self-developed real-time voltage stability analysis application and contingency analysis application was used. CIM HSDA was used for data input and real-time analysis. Tolerance of result which is in the range of allowable derived by Perform real-time voltage stability and contingency analysis of Jeju power system, and then compare it's result with PSS/E result.

Wide Frequency Current Source Inverter (광역 주파수 전류원형 인버터)

  • 전성즙;조규형
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.927-935
    • /
    • 1994
  • Detailed analysis of the commutation circuit of the proposed wide-frequency current source inverter is given. In this inverter a spike-limit circuit and a precommutation circuit are used. The spike-limit circuit is intended to limit spike voltage which is arising during commutation time in a current source inverter, and the precommutation circuit to reuse the energy which flows from main inverter to spike-limit circuit during commutation time to aid commutation. Thus voltage stress of main thyristor is minimized. Since this inverter can be made up of thyristors for phase control, it has some advantage in high voltage and high power application.

High Speed Response Time of Nematic Liquid Crystal Mixtures for LCD Monitor and TV Applications

  • Kim, Y.B.;Hur, I.K.
    • Journal of Information Display
    • /
    • v.2 no.3
    • /
    • pp.32-38
    • /
    • 2001
  • The most important parameter for TV application of LCD is a fast switching time for the display of moving image. To achieve faster switching time, the novel LC single materials with large dielectric anisotropies ($16{\sim}20$), high clearing temperatures ($195.5{\sim}237.4^{\circ}C$), broad nematic ranges (up to 169.9 $^{\circ}C$) and high birefringence ($0.254{\sim}0.2200$) were developed. KUR-series LC mixtures blended these single materials having significantly higher clearing temperatures and dielectric anisotropy values compared with conventional LC mixture. Especially, their clearing temperatures are $10{\sim}30^{\circ}C$ higher than their host mixture. These LC mixtures showing about lOms of high-speed switching time in Tv/Monitor of TFT LCD, is short enough to be addressed in a single time frame of 60Hz (16.7 ms). The threshold voltage $V_{th}$ was low enough to operate at a driving voltage of 5 V. The VHR values were found to be high enough for TFT-LCD in wide temperature range. Our novel LC mixtures are suitable materials for the inclusion in to LC mixtures for TV application of TN-LCD

  • PDF

A Basic Study on the Attachment Process of Lightning Leader to Ground (낙뢰 리더의 대지부착과정에 대한 기초적 연구)

  • Yoo, Yang-Woo;Kim, Seung-Min;Kim, You-Ha;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.82-88
    • /
    • 2014
  • This paper presents the results of model tests for the attachment process of lightning leader to ground which is one of poorly understood processes of cloud-to-ground lightning discharges. In order to simulate the attachment process of lightning leader to ground, we investigated the discharge characteristics of air gap between the tip of needle-shaped electrode and the soil surface as a parameter of moisture content in soils when the positive and negative $1.2/50{\mu}s$ lightning impulse voltages are applied. The breakdown voltage and the discharge light were observed. As a result, the attachment processes of lightning leader to ground are strongly dependent on the grain size and the moisture content of soils. The time to breakdown was shortened with increasing the magnitude of incident impulse voltages. The delay time from application of the highest voltage to breakdown in sand is shortened with increasing the moisture content. The delay time from application of the voltage to breakdown in gravel varied from about $0.5{\mu}s$ to several ${\mu}s$. As the moisture content in soil increases, the breakdown voltages are decreased and the breakdown voltage versus time to breakdown curves are shifted toward the lower side. The results obtained in this work are similar to those for non-uniform air gap stressed by lightning impulse voltages.

A Study on the Design of the rated insulation voltage of 690V for the low-voltage switchgear and controlgear (저압기기 정격절연전압 690V 개발시 고려사항에 대한 연구)

  • Kim, Myoung-Seok;Kim, Jong-Yeok;Park, Sang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.961-963
    • /
    • 2000
  • Most of the application standard of the low-voltage devices have applied one the IEC standard another the UL standard. European union applied the IEC60947-1 standard has not exceed 1000V a.c. or 1500V d.c.. Therefore. it is necessary to the low-voltage device has expended for rated operational voltage with our products. The export of European market shall be made for the CE-Marking in accordance with IEC60947-1 ( Low-voltage switchgear and controlgear). We shall be considered for the requirement with the IEC standard. In this time to study for power supply system at EU ( European union. At that time for design and development in order to the construction and test method among the study for the rated insulation voltage at less then 690V.

  • PDF

An Estimation of Breakdown Time of the Epoxy Composites according to Filler and Silane Treatment (충진제와 실란처리에 따른 에폭시 복합체의 파괴시간 예측)

  • Shin, Cheol-Gi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.793-797
    • /
    • 2007
  • In this paper, the long time breakdown characteristic of the epoxy composite, which is widely used in the insulation system for high voltage application, was estimated with Weibull distribution. In the procedure of the estimation, the short time breakdown characteristics for the epoxy composite specimens, which were made with the variation of hardener and/or filler, were tested firstly. Then the long time voltage-to-time test was implemented. Finally, the long time breakdown voltage of each specimen was estimated with the parameters obtained from the statistical treatment with Weibull distribution. Base on the results, it has been found that the optimal weight ratio of epoxy resin/hardener/filler that has the excellent long time breakdown characteristic was 100/100/65. It was due to the silane treatment which relieves the electric field at the interface between filler and epoxy.