• 제목/요약/키워드: Voltage Analysis Method

검색결과 1,789건 처리시간 0.026초

DVR의 특성을 고려한 매칭변압기의 자속포화 해석 (Magnetic Flux Saturation Analysis of Matching Transformer Considering Characteristic of Dynamic Voltage Restorer(DVR))

  • 손진근;김동준;강민구;전희종
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.236-243
    • /
    • 2008
  • This paper analyses magnetic flux saturation of matching transformer considering characteristic of dynamic voltage restorer(DVR) system to solve voltage sags which are considered the dominant disturbances affecting power quality. This DVR consist of PWM inverter to inject arbitrary voltage, LC low pass filter and matching transformer for isolation and grid connection. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core of transformer. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, an advanced modeling method of magnetic flux saturation is used to analyze a magnitude and characteristic of magnetizing current. Simulation and experimental results considering characteristic of DVR system are provided to demonstrate the validity of the proposed analysis method.

A Positioning Method of Distributed Power System by Considering Characteristics of Droop Control in a DC Microgrid

  • Ko, Byoung-Sun;Lee, Gi-Young;Kim, Sang-Il;Kim, Rae-Young;Cho, Jin-Tae;Kim, Ju-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.620-630
    • /
    • 2018
  • In this paper, a positioning method of distributed power system is proposed to minimize the average voltage variation of a DC microgrid through voltage sensitivity analysis. The voltage sensitivity under a droop control depends on the position of the distributed power system. In order to acquire a precise voltage sensitivity under a droop control, we analyzed the power flow by introducing a droop bus with the considerations of the droop characteristics. The results of the positioning method are verified through PSCAD/EMTDC simulation.

22.9kV급 병렬 커패시터 뱅크 내부의 아크 고장 판별을 위한 전압차동 보호 알고리즘의 개선 방안 (Improvement of the Protection Algorithm Based on Voltage Difference Method for Detecting Arcing Faults within 22.9kV Shunt Capacitor Banks)

  • 임정욱;권영진;강상희;육유경
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권2호
    • /
    • pp.61-66
    • /
    • 2005
  • This paper presents a refined protection algorithm of the unfused 22.9kV shunt capacitor banks in grounded wye connection to improve the existing algorithm using the voltage difference method. It is difficult to detect ground faults with arc near the input points or ground faults near the grounding point by the existing algorithm using only the voltage balanced relay. This paper shows that ground faults with arc near the input point can be detected by harmonics analysis of the differential voltage and that it has no impact of harmonics out of nonlinear loads which have the quantitative influence on capacitor banks. Thus the proposed method using harmonics analysis can be a proper detection method. In case of ground faults near the grounding point, an OVGR is being added recently and its validity is verified in this paper. The proposed method is applied to a 22.9kV example system and is verified that the proposed algorithm can detect clearly faults which are not easy to detect by the existing method.

순간전압강하 평가에 기반한 최적 보상기기 선정 방법 (Method to Select Optimal Device for Mitigating Voltage Sag Based on Voltage Sag Assessment)

  • 이계병;한종훈;장길수;박창현
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.29-34
    • /
    • 2015
  • This paper presents a method to select optimal device for mitigating voltage sags. The method is based on economic evaluation and voltage sag assessment involving sag duration as well as magnitude. The economic evaluation is performed by using the operation cost and economic benefit of the mitigation devices. The optimal device can be determined from the values of NPV (net present value) which is widely accepted in cost-benefit analysis. The proposed method can help sensitive customers to select optimal mitigation device. In this paper, the case study considering two sensitive customers was performed by using the proposed method.

Voltage Source FEA for Hysteresis Motor using Preisach Model

  • Hong, Sun-Ki;Lee, Seok-Hee;Jung, Hyun-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.164-168
    • /
    • 2001
  • In this paper voltage source FEA for hysteresis motor considering magnetic hysteresis characteristics is presented. The Preisach model is used as a hysteresis model. System matrix whose unknown variables are vector potentials and currents is formulated for voltage source. The stiffness matrix is maintained constant by using M-iteration method. Therefore the calculation time and efforts are reduced with Choleski direct method. Current waveform can be calculated for arbitrary voltage vaveform considering hysteresis effects.

  • PDF

주파수 분석기법을 이용한 전압 평활용 전해 커패시터의 고장진단 (Frequency Analysis Method Based Fault Diagnosis of an Electrolytic Capacitor for Voltage Smoothing)

  • 손진근;김진식
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.207-213
    • /
    • 2009
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. This paper proposed a novel fault diagnosis method of an electrolytic capacitor used for voltage smoothing in boost DC converter. The equivalent series resistance(ESR) of electrolytic capacitor estimated from FFT result of filtered waveform of capacitor voltage/current. Main advantage of the proposed method include circuit simplicity and easy implementation. Simulation and experimental results are shown to verify the performance of the proposed method.

Design and Control Methods of Bidirectional DC-DC Converter for the Optimal DC-Link Voltage of PMSM Drive

  • Kim, Tae-Hoon;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1944-1953
    • /
    • 2014
  • This paper shows the design and control methods of the bidirectional DC-DC converter to generate the proper DC-link voltage of a PMSM drive. Conventionally, because the controllable power of the PWM based voltage source inverter is limited by its DC-link voltage, the DC-DC converter is used for boosted DC-link voltage if the inverter source cannot generate enough operating voltage for the PMSM drive. In this paper, to obtain more utilization of this DC-DC converter, optimal DC-link voltage control for PMSM drive will be explained. First, the process and current path of the DC-DC converter will be illustrated, and a control method of this converter for variable DC-link voltage will then be explained. Finally, an improvement analysis of the optimal DC-link voltage control method, especially on the deadtime effect, will be explained. The DC-DC converter of the proposed control method is verified by the experiments by comparing with the conventional constant voltage control method.

Feasible Power Loss Analysis and Estimation of Auxiliary Resonant DC Link Assisted Soft-Switching Inverter with New Zero Vector Generation Method

  • Manabu Kurokawa;Claudio Y. Inaba;M. Rukonuzzaman;Eiji Hiraki;Yoshihiro Konishi;Mutsuo Nakaoka
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.77-87
    • /
    • 2002
  • The purpose of this paper is to improve power conversion efficiency of three-phase soft-switching voltage-source inverter with an auxiliary resonant dc link (ARDCL) snubber circuit. Firstly, the operation principle of ARDCL snubber circuit is described. Secondly, this paper proposes an effictive generation method of zero voltage vector for three-phase voltage-source soft-switching inverter in power losses in which power losses in the ARDCL snubber circuit can be reduced. In particular, zero voltage holding interval in the inverter DC busline can be controlled due to the new generation scheme of zero voltage vector. Thirdly, a simulator for power loss analysis for power loss characteristics based on actual system, is developed. the validity of developed. The validity of developed simulator of proved with experimental results. Finally, power efficency of three-phase inverter is estimated according to high carrier frequency by using the simulatior.

Z-소스 교류 컨버터 토폴로지의 동적 전압 보상기 (Dynamic Voltage Restorer(DVR) with a Z-Source AC Converter Topology)

  • 임영철;정영국
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.36-43
    • /
    • 2010
  • This paper proposes a new type of voltage sag-swell compensator based on a Z-source AC-AC converter. The proposed topology employs a pulse width modulation (PWM) Z-source AC-AC converter along with a injection transformer. A safe commutation strategy is used to eliminate voltage spikes on switches without snubber circuit. During a voltage sag or swell, the proposed system controls the adding or missing voltage and maintains the rated voltage of sinusoidal waveform at the terminals of the critical loads. The proposed system is able to compensate 20[%] voltage swell and is also able to compensate 60[%] voltage sag. In order to control and detect the voltage sag and swell, the peak voltage detection method is applied. Also, the operating principles of the proposed system are described, and a circuit analysis is provided. Finally, PSIM simulation and experimental results are presented to verify the proposed concept and theoretical analysis.

농형 유도 발전기의 소프트 기동 특성 해석 (Soft Start-up Characteristics Analysis of Squirrel Cage Induction Generator)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.103-107
    • /
    • 2016
  • In general, the voltage stability of induction generator is lower than synchronous generator. Induction generator has a number of advantages over the synchronous generator on the side of price and maintenance. So Induction generator has been applied to the small hydroelectric power of low output. Induction generator usually generates a high current during grid connection. The high current that occurs during grid connection can cause a voltage drop in the system. In order to increase the supply of the induction generator, it is necessary to propose a method of reducing high current. This paper proposes some method of the soft start to reduce voltage drop caused by the large starting current. soft-start method has high voltage drop effect than direct start method, control of firing angle can be increased the voltage drop effect.