• 제목/요약/키워드: Voltage Analysis Method

검색결과 1,789건 처리시간 0.034초

전압을 구동함수로 한 선형 유도전동기의 유한요소 해석 (Finite Element Analysis of L.I.M. Considering the Voltage as a Driving Source)

  • 임달호;최창규
    • 대한전기학회논문지
    • /
    • 제40권3호
    • /
    • pp.250-257
    • /
    • 1991
  • In the analysis of the electric machine by finite element method, the primary current has been selected as a driving source. But the voltage is constant and the primary current varies according to the load condition in the pracdtical system. Therefore, in this paper, magnetic flux distribution, primary current, input effective power, power factor, efficiency and propulsion force of S.L.I.M. were calculated by the finite element method cnsidering the voltage as a driving source. Because the driving characteristics could not be measured in the S.L.I.M., voltage-current curve, 3-phase current curve, and propulsion force were measured at the starting and they were compared with theoretical values.

QSS 해석 기법을 이용한 Voltage Security Assessment(VSA) 프로그램 기반설계 (Framework Design of Voltage Security Assessment(VSA) using QSS Analysis method)

  • 허진;이상호;김태현;문영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.12-14
    • /
    • 2005
  • Security problem has been a fundamental issue in the operation and planning of power system. Voltage instability is widely recognized as an important issue of power system blackout. As far as real-time operation is concerned, there is a need for appropriate tools to identify dangerous contingencies, assess security margins and suggest corrective actions. In this paper, we propose the framework design of Voltage Security Assessment(VSA) using QSS(Quasi Steady-State) analysis method in order to implement fast time domain simulation engine as a major part of VSA.

  • PDF

2010년 여름철 전력계통 최적 운영에 관한 연구 (A Study on the Optimal Operation of 2010 Summer Peak in Korea Power System)

  • 이성무;조종만;김규호
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1733-1740
    • /
    • 2010
  • KPX(Korea Power Exchange) predicts that summer peak load will be 70,700MW and system overload will be 150% from contingency analysis. This paper presents a method to operate power system at 2010 summer peak. about equipment variation, power system variation, analysis results of voltage stability, and the method to relief overload by comparing 2009 and 2010. Especially, transmission constraints to prevent global contingency in Korea power system and the role of SPS(Special Protection System) to prevent voltage collapse when fault occurs are introduced.

고정자전압제어 전류형 인버터에 의한 유도전동기 구동시스템의 안정도 해석 (Stability Analysis of Induction Motor Driven by Stator Voltage Controlled CSI)

  • Song, Joong-Ho;Yoon, Tae-Woong;Youn, Myung-Joong
    • 대한전기학회논문지
    • /
    • 제41권1호
    • /
    • pp.32-41
    • /
    • 1992
  • This paper presents a comprehensive study on the stability of several control schemes for the induction motor driven by current source inverters. A stator voltage controlled current source inverter drive system without a speed sensor is investigated in order to find appropriate control schemes, which are primarily based on direct or, alternatively, indirect frequency control scheme. It can be seen, especially that an introduction of the indirect frequency control method improves the inherent instability of the current source inverter drive system for the induction motor. The overall control systems with either voltage control loop or current and voltage control loops in addition to each frequency control scheme, are analyzed by utilizing the root locus method and simulated by computer to show the validity of this analysis.

구조-음향 상반성 원리를 이용한 공기기인 소음원의 강도 추정 및 소음 합성 (The Use of Vibro-acoustical Reciprocity to Estimate Source Strength and Airborne Noise Synthesis)

  • 김윤재;변재환;강연준;홍진철;권오준;강구태
    • 한국소음진동공학회논문집
    • /
    • 제19권1호
    • /
    • pp.42-49
    • /
    • 2009
  • In this paper, an alternative method was introduced to conduct a transfer path analysis for airborne noise. The method used the transfer function matrix composed of acoustic transfer functions that are referenced by the input voltage of a calibration source. A calibration factor which is converting a virtual voltage to source strength was deduced by vibro-acoustical reciprocity theorem. The calibration factor is then multiplied to the virtual input voltage to estimate the operational source strength. Three loudspeakers were used to noise sources of acrylic half car model. The method was applied to airborne noise transfer path analysis of the half car. The estimated source strength by transfer path analysis was compared the deduced source strength by vibro-acoustical reciprocity to verify the method.

A Novel SVPWM Strategy Considering DC-link Balancing for a Multi-level Voltage Source Inverter

  • Kim, Rae-Young;Lee, Yo-Han;Hyun, Dong-Seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.159-164
    • /
    • 1998
  • This paper proposes a SVPWM (space vector pulse width modulation) strategy for a multi-level voltage source inverter. This strategy is easily implemented as SPWM (sinusoidal pulse width modulation) and has the same DC-link voltage utilization as general SVPWM. The method to keep the voltage balancing of DC-link also is proposed by the analysis model of DC-link voltage fluctuation. The usefulness of the proposed SVPWM is verified through the simulation.

  • PDF

직류 전차 탑재형 피뢰기의 하우징 설계 및 성능평가 (Performance Evaluation and Housing Design for Direct Current Surge Arrester in Railway Rolling Stock)

  • 조한구;김석수;한세원;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.128-131
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for DC power system of railroad vehicles. The rated voltage is 1500V direct current. The main research works are focused on structure design by finite element method, rating voltage, temporary over voltage and studies of characteristics of polymeric surge arrester.

  • PDF

NPC와 B-Bridge 컨버터의 부스트 벡터와 커패시터전압의 해석 (Analysis of Capacitor Voltage and Boost Vector in Neutral-Point-Clamped and H-Bridge Converter)

  • 김정균;김태진;강대욱;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.489-493
    • /
    • 2002
  • This paper discover another boost vectors in high modulation index In steady states, modulation index of converter operation is normally $0.7\~0.8[p.u]$. Even though zero vectors are not imposed, DC-Link voltage is constant because 3-level boost convert has another boost vectors. and this paper proposes the analysis and the comparison for NPC and H-Bridge converter. It proposed the calculation method for the voltage ripple and charging current of each capacitor and deals with voltage balance problems of each link capacitor they are associated with the switching state, the position of reference voltage vector. Simulation and analysis are used in order to prove validity of the proposed methods.

  • PDF

Neutral-Point Voltage Balancing Method for Three-Level Inverter Systems with a Time-Offset Estimation Scheme

  • Choi, Ui-Min;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.243-249
    • /
    • 2013
  • This paper presents a neutral-point voltage balancing method for three-level inverter systems using a time-offset estimation scheme. The neutral-point voltage is balanced by adding a time-offset to the turn-on time of the switches. If an inaccurate time-offset is added, the neutral-point deviation still remains. An accurate time-offset is obtained through the proposed time-offset estimation scheme. This method is implemented without additional hardware, complex calculations, or analysis. The effectiveness of the proposed method is verified by experiments.

Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller

  • Lee, Jong-Hyun;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.918-925
    • /
    • 2012
  • This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition and compensate for the low-order harmonics of the output currents caused by the distortion of grid voltage. To reduce the power ripple, our method replaces the two conventional PI controllers with one PR controllers in the stationary frame. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulated and experimental results agree well with the theoretical analysis.