• 제목/요약/키워드: Voltage Absence

검색결과 81건 처리시간 0.019초

수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰 (Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash)

  • 이기연;길형준;김동욱;김동우;강대철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

그림자 조건에서 태양광 패널의 접속구조에 따른 발전량 분석 (Analysis on Generation Power according to Connection Structure for PV Panel under Shadow Condition)

  • 정우용;김용중;김효성
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.94-102
    • /
    • 2020
  • Considering that the output voltage and current of a single PV panel are limited in PV power generation, a PV array should be constructed by connecting several PV panels in series and parallel to meet the required voltage/power levels for power generation capacity. When a PV array is partially shaded, the maximum power generation depends on the configuration of a PV array and the presence or absence of blocking diodes. This study considers six PV array configurations and the presence or absence of blocking diodes. An optimum connection structure was proposed to maximize power generation in a partial shadow condition. Results were verified through simulation and an experiment.

교류전기장이 프로판 난류제트 화염의 부상특성에 미치는 영향 (A Study on the Effect of AC Electric Field on the Liftoff Characteristics of Turbulent Propane Jets.)

  • 박철수;이상민;차민석;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.83-88
    • /
    • 2004
  • High voltage AC electric field has been applied to turbulent propane jets to investigate the effect of electric field on liftoff characteristics. Liftoff velocity and liftoff height have been measured by varying the applied voltage and frequency. Liftoff velocities were delayed and liftoff heights were reduced by applying AC, not by DC. The electric effect became disappeared with further increasing jet velocities, which shows that the effect can be explained by the balance between inertia force and electric force. The flame stabilization effect was intensified as either applied voltage or frequency increased. Plasma streamers were generated between the flame and the jet under high voltage conditions. Liftoff velocity in the absence of plasma can be well correlated by the function of voltage and frequency.

  • PDF

Design and Development of a High-Voltage Transformer-less Power Supply for Ozone Generators Based on a Voltage-fed Full Bridge Resonant Inverter

  • Amjad, Muhammad;Salam, Zainal;Facta, Mochammad;Ishaque, Kashif
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.387-398
    • /
    • 2012
  • It is known that transformer based power supplies for ozone generators have low efficiency, high cost and exhibits a limited frequency range of operation. To overcome these disadvantages, this paper proposes a high frequency ozone generator with the absence of a transformer. The voltage step-up is achieved only by utilizing the resonant tank. This is made possible by a novel combination of ozone chamber materials that allow ozone to be generated at only 1.5 - 3.5 $kV_{p-p}$. The input to the resonant tank is driven by a PWM full bridge resonant inverter. Furthermore, zero-current zero-voltage switching (ZCZVS) operation is achieved by employing a duty factor of 25% between the switches of the full bridge. The advantages of the proposed system include high efficiency, low cost and the ability to control ozone production by varying the input voltage to the inverter. The prototype is verified by both simulation and experimental results.

Single-Inductor, Multiple-Input-Single-Output Converter Based Energy Mixer for Power Packet Distribution System

  • Reza, C.M.F.S.;Lu, Dylan Dah-Chuan;Qin, Ling;Qi, Jian
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1479-1488
    • /
    • 2018
  • Power packet (PP) distribution system distributes power to different loads that share the same distribution cable in a packetized form. When compared with conventional power systems, a PP distribution system (PPDS) can reduce standby power, eliminate Point-of-Load (PoL) power conversion, and intelligently control the load demand from the source side. Due to the absence of PoL conversion, when multiple power sources at different voltage levels and conditioning requirements jointly send power to various loads at different voltage ratings, the generated voltage has an irregular shape. A large filter at each of the load sides is required to reduce such a large voltage ripple. In this paper, a single-inductor, multiple-input-single-output converter structure based multiple-energy-source mixer is proposed. It combines PP generation, maximum power point tracking (MPPT) of renewable energy sources (RESs) and filtering at the source side. To demonstrate the possible renewable energy integration, a PV panel is used as a power source together with other constant voltage sources. The PV power is approximately tracked using the constant voltage method and it is used for each of the PP generations. The proposed PP distribution system is experimentally verified and it is shown that a conventional PI controller is sufficient for stable system operation.

가변 병렬 터미네이션을 가진 단일 출력 송신단 (A Single-Ended Transmitter with Variable Parallel Termination)

  • 김상훈;어지훈;장영찬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.490-492
    • /
    • 2010
  • Center-tapped termination을 가진 stub series-termination logic (SSTL) 채널을 지원하기 위한 전압모드 송신단을 제안한다. 제안하는 송신단은 진단 모드를 지원하고 신호보전성을 향상시키기 위해 출력레벨 조절수단을 가지며, 가변 병렬 터미네이션을 사용하여 swing level을 조절하는 동안 송신단의 출력 저항을 일정하게 유지시켜준다. 또한 제안하는 송신단의 off-chip 저항은 기생 캐패시터, 인덕터에 의한 termination의 임피던스 부정합을 줄여준다. 제안된 송신단을 검증하기 위해서 $50{\Omega}$의 출력저항을 유지하면서 8-레벨의 출력을 제공하는 전압모드 송신단을 1.5V의 70nm 1-poly 3-metal DRAM공정을 이용하여 구현하였다. 수신단 termination이 존재하지 않는 SSTL 채널에서 제안하는출력레벨 조절이 가능한 송신단을 이용함으로 1.6-Gb/s에서 54%의 jitter 감소가 측정되었다.

  • PDF

선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성 (Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

Modulation of Cloned T-type Calcium Channels

  • Jeong, Seong-Woo
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 2002년도 제9회 학술 발표회 프로그램과 논문초록
    • /
    • pp.20-21
    • /
    • 2002
  • The inflow of Ca$\^$2+/ through voltage-activated T-type calcium channels (T-channels) regulates a variety of cellular functions including neuronal excitability, cardiac pacemaker activity, hormone secretion, smooth muscle contraction, and fertilization. Not only are T-channels enormously important for the normal operation of cells, they also playa critical role in pathophysiological conditions such as cardiac hypertrophy and absence epilepsy.(omitted)

  • PDF

Stability Comparison of New Simplified Speed Sensorless Vector Control Systems for Induction Motors

  • Mangindaan, Glanny M.Ch.;Tsuji, Mineo;Hamasaki, Sin-Ichi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.126-131
    • /
    • 2014
  • This paper discusses stability of new simplified sensorless vector control systems of induction motors (IM). The simplified sensorless systems estimate the flux angle by using the output voltage of d-axis PI current controller to achieve the q-axis flux zero. Two simplified sensorless systems are studied. The difference of two systems is the presence or absence of a q-axis PI current controller. The systems stability is compared by deriving linear state equations and showing root loci and unstable regions. Furthermore, transient responses and experiment results make clear the stability of the proposed system.

수직 광폴리머를 이용한 MVA 셀의 전기 광학 특성 (EO Characteristics in the Multidomain Vertical-Alignment (MVA) Cell on a Homeotropic Photopolymer)

  • 이경준;황정연;김재형;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.953-956
    • /
    • 2002
  • The electro-optical (EO) performances of a multidomain vertical-alignment (MVA) cell on a homeotropic photopolymer have been investigated. In the absence of an electric field, the MVA cell achieved black state as LC alignment is homeotropic. An electric field created by interdigitated electrodes and rib made after photolithograph using the photopolymer on both substrates causes a director deformation of a multidomain type. Good voltage-transmittance curves for a MVA cell on the homeotropic photopolymer were observed. Also, the stable response time of MVA cell on the homeotropic photopolymer can be achieved.

  • PDF