• Title/Summary/Keyword: Voltage Absence

Search Result 81, Processing Time 0.023 seconds

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash (수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰)

  • Lee, Kiyeon;Gil, Hyoungjun;Kim, Dongook;Kim, Dongwoo;Kang, Daechul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

Analysis on Generation Power according to Connection Structure for PV Panel under Shadow Condition (그림자 조건에서 태양광 패널의 접속구조에 따른 발전량 분석)

  • Jeong, Woo-Yong;Kim, Yong-Jung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Considering that the output voltage and current of a single PV panel are limited in PV power generation, a PV array should be constructed by connecting several PV panels in series and parallel to meet the required voltage/power levels for power generation capacity. When a PV array is partially shaded, the maximum power generation depends on the configuration of a PV array and the presence or absence of blocking diodes. This study considers six PV array configurations and the presence or absence of blocking diodes. An optimum connection structure was proposed to maximize power generation in a partial shadow condition. Results were verified through simulation and an experiment.

A Study on the Effect of AC Electric Field on the Liftoff Characteristics of Turbulent Propane Jets. (교류전기장이 프로판 난류제트 화염의 부상특성에 미치는 영향)

  • Park, Chul-Soo;Lee, Sang-Min;Cha, Min-Suk;Chung, Suk-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.83-88
    • /
    • 2004
  • High voltage AC electric field has been applied to turbulent propane jets to investigate the effect of electric field on liftoff characteristics. Liftoff velocity and liftoff height have been measured by varying the applied voltage and frequency. Liftoff velocities were delayed and liftoff heights were reduced by applying AC, not by DC. The electric effect became disappeared with further increasing jet velocities, which shows that the effect can be explained by the balance between inertia force and electric force. The flame stabilization effect was intensified as either applied voltage or frequency increased. Plasma streamers were generated between the flame and the jet under high voltage conditions. Liftoff velocity in the absence of plasma can be well correlated by the function of voltage and frequency.

  • PDF

Design and Development of a High-Voltage Transformer-less Power Supply for Ozone Generators Based on a Voltage-fed Full Bridge Resonant Inverter

  • Amjad, Muhammad;Salam, Zainal;Facta, Mochammad;Ishaque, Kashif
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.387-398
    • /
    • 2012
  • It is known that transformer based power supplies for ozone generators have low efficiency, high cost and exhibits a limited frequency range of operation. To overcome these disadvantages, this paper proposes a high frequency ozone generator with the absence of a transformer. The voltage step-up is achieved only by utilizing the resonant tank. This is made possible by a novel combination of ozone chamber materials that allow ozone to be generated at only 1.5 - 3.5 $kV_{p-p}$. The input to the resonant tank is driven by a PWM full bridge resonant inverter. Furthermore, zero-current zero-voltage switching (ZCZVS) operation is achieved by employing a duty factor of 25% between the switches of the full bridge. The advantages of the proposed system include high efficiency, low cost and the ability to control ozone production by varying the input voltage to the inverter. The prototype is verified by both simulation and experimental results.

Single-Inductor, Multiple-Input-Single-Output Converter Based Energy Mixer for Power Packet Distribution System

  • Reza, C.M.F.S.;Lu, Dylan Dah-Chuan;Qin, Ling;Qi, Jian
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1479-1488
    • /
    • 2018
  • Power packet (PP) distribution system distributes power to different loads that share the same distribution cable in a packetized form. When compared with conventional power systems, a PP distribution system (PPDS) can reduce standby power, eliminate Point-of-Load (PoL) power conversion, and intelligently control the load demand from the source side. Due to the absence of PoL conversion, when multiple power sources at different voltage levels and conditioning requirements jointly send power to various loads at different voltage ratings, the generated voltage has an irregular shape. A large filter at each of the load sides is required to reduce such a large voltage ripple. In this paper, a single-inductor, multiple-input-single-output converter structure based multiple-energy-source mixer is proposed. It combines PP generation, maximum power point tracking (MPPT) of renewable energy sources (RESs) and filtering at the source side. To demonstrate the possible renewable energy integration, a PV panel is used as a power source together with other constant voltage sources. The PV power is approximately tracked using the constant voltage method and it is used for each of the PP generations. The proposed PP distribution system is experimentally verified and it is shown that a conventional PI controller is sufficient for stable system operation.

A Single-Ended Transmitter with Variable Parallel Termination (가변 병렬 터미네이션을 가진 단일 출력 송신단)

  • Kim, Sang-Hun;Uh, Ji-Hun;Jang, Young-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.490-492
    • /
    • 2010
  • A swing level controlled voltage-mode transmitter is proposed to support a stub series-terminated logic channel with center-tapped termination. This transmitter provides a swing level control to support the diagnostic mode and improve the signal integrity in the absence of the destination termination. By using the variable parallel termination, the proposed transmitter maintains the constant output impedance of the source termination while the swing level is controlled. Also, the series termination using an external resistor is used to reduce the impedance mismatch effect due to the parasitic components of the capacitor and inductor. To verify the proposed transmitter, the voltage-mode driver, which provides eight swing levels with the constant output impedance of about $50{\Omega}$, was implemented using a 70nm 1-poly 3-metal DRAM process with a 1.5V supply. The jitter reduction of 54% was measured with the swing level controlled voltage-mode driver in the absence of the destination termination at 1.6-Gb/s.

  • PDF

Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode (선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

Modulation of Cloned T-type Calcium Channels

  • Jeong, Seong-Woo
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2002.06b
    • /
    • pp.20-21
    • /
    • 2002
  • The inflow of Ca$\^$2+/ through voltage-activated T-type calcium channels (T-channels) regulates a variety of cellular functions including neuronal excitability, cardiac pacemaker activity, hormone secretion, smooth muscle contraction, and fertilization. Not only are T-channels enormously important for the normal operation of cells, they also playa critical role in pathophysiological conditions such as cardiac hypertrophy and absence epilepsy.(omitted)

  • PDF

Stability Comparison of New Simplified Speed Sensorless Vector Control Systems for Induction Motors

  • Mangindaan, Glanny M.Ch.;Tsuji, Mineo;Hamasaki, Sin-Ichi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.126-131
    • /
    • 2014
  • This paper discusses stability of new simplified sensorless vector control systems of induction motors (IM). The simplified sensorless systems estimate the flux angle by using the output voltage of d-axis PI current controller to achieve the q-axis flux zero. Two simplified sensorless systems are studied. The difference of two systems is the presence or absence of a q-axis PI current controller. The systems stability is compared by deriving linear state equations and showing root loci and unstable regions. Furthermore, transient responses and experiment results make clear the stability of the proposed system.

EO Characteristics in the Multidomain Vertical-Alignment (MVA) Cell on a Homeotropic Photopolymer (수직 광폴리머를 이용한 MVA 셀의 전기 광학 특성)

  • Lee, Kyung-Jun;Hwang, Jeoung-Yeon;Kim, Jae-Hyung;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.953-956
    • /
    • 2002
  • The electro-optical (EO) performances of a multidomain vertical-alignment (MVA) cell on a homeotropic photopolymer have been investigated. In the absence of an electric field, the MVA cell achieved black state as LC alignment is homeotropic. An electric field created by interdigitated electrodes and rib made after photolithograph using the photopolymer on both substrates causes a director deformation of a multidomain type. Good voltage-transmittance curves for a MVA cell on the homeotropic photopolymer were observed. Also, the stable response time of MVA cell on the homeotropic photopolymer can be achieved.

  • PDF