• Title/Summary/Keyword: Volar plate

Search Result 11, Processing Time 0.032 seconds

Volar plate avulsion fracture alone or concomitant with collateral ligament rupture of the proximal interphalangeal joint: A comparison of surgical outcomes

  • Kim, Yong Woo;Roh, Si Young;Kim, Jin Soo;Lee, Dong Chul;Lee, Kyung Jin
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.458-465
    • /
    • 2018
  • Background Volar plate avulsion fracture of the proximal interphalangeal (PIP) joint is one of the most common hand injuries. In this study, we divided patients into two groups: patients with pure volar plate avulsion fracture, and patients with volar plate avulsion fracture concomitant with collateral ligament rupture. The purpose of this study was to compare long-term surgical outcomes between the two groups. As a secondary measure, the Mitek bone anchoring and polydioxanone (PDS) bone suturing techniques were compared. Methods A single-institutional retrospective review of the surgical treatment of volar plate avulsion fracture was performed. The cases were divided into those with pure volar plate avulsion fracture (group A, n=15) and those with volar plate avulsion fracture concomitant with collateral ligament rupture (group B, n=15). Both groups underwent volar plate reattachment using Mitek bone anchoring or PDS bone suturing followed by 2 weeks of immobilization in a dorsal protective splint. Results The average range of motion of the PIP joint and extension lag were significantly more favorable in group A (P<0.05). Differences in age; follow-up period; flexion function; visual analog scale scores; disabilities of the arm, shoulder, and hand scores; and the grip strength ratio between the two groups were non-significant. No significant differences were found in the surgical outcomes of Mitek bone anchoring and PDS bone suturing in group A. Conclusions Overall, the surgical outcomes of volar plate reattachment were successful irrespective of whether the collateral ligaments were torn. However, greater extension lag was observed in cases of collateral ligament injury.

Open Reduction of Proximal Interphalangeal Fracture-Dislocation through a Midlateral Incision Using Absorbable Suture Materials

  • Lee, Jae Jun;Park, Hyoung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.397-402
    • /
    • 2013
  • Background Fracture-dislocation of the proximal interphalangeal (PIP) joint is a relatively common injury. Various treatments for fracture-dislocation of the PIP joint have been reported. In the present study, we performed open reduction through a midlateral incision using absorbable sutures to reduce the small bone fragments and performed volar plate repair. Methods We treated nine patients with fracture-dislocation of the PIP joint with small fractured bone fragments too small for pinning or screw fixation. Patients with volar plate injury were treated with open reduction and volar plate repair at the periosteum of the middle phalangeal bone base by the modified Kessler method using absorbable sutures. All patients were placed in a dorsal aluminum extension block splint, which maintained the PIP joint in approximately 30 degrees of flexion to avoid excessive tension on the sutured volar plate. Results At a mean final follow-up of postoperative 9 months, all patients were evaluated radiographically and had adequate alignment of the PIP joint and reduction of the displaced bone fragments. Range of motion was improved and there were no complications. Conclusions This technique is an excellent alternative to the current method of treating patients with fracture-dislocations that include small fragments that are too small for pinning or screw fixation. It is a less invasive surgical method and enables stable reduction and early exercise without noticeable complications.

Morphometric Variations in the Volar Aspect of the Distal Radius

  • Kwon, Bong Cheol;Lee, Joon Kyu;Lee, Suk Yoon;Hwang, Jae Yeun;Seo, Jang-Hyeon
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.462-467
    • /
    • 2018
  • Background: Significant discrepancy exists between anatomical plate designs and the anatomy of the native distal radius, which may be attributable to considerable morphometric variations in the volar aspect of the distal radius. We aimed to evaluate the degree of variability in the morphometry of the distal radius and identify factors associated with this variability. Methods: We measured the volar surface angle (VSA) of the intermediate and lateral columns and the volar surface width (VSW) in the distal radius from three-dimensional computed tomography scans acquired from 81 cadaveric forearms. These morphometric parameters were compared between the lateral and intermediate columns, between males and females, and between Koreans and Caucasians. Caucasian morphometric data were obtained and pooled from the previous studies. The coefficient of variation was used to assess the variability of the parameters and Cohen's d to estimate the effect size of the difference between groups. Results: The average VSA of the lateral column was $22^{\circ}{\pm}6^{\circ}$, and that of the intermediate column was $29^{\circ}{\pm}8^{\circ}$ in Koreans (p < 0.001). The variability was high for both VSAs. The VSA of the intermediate column was significantly larger in males than in females (p < 0.001) and in Caucasians than in Koreans (p < 0.001). The average VSW of distal radius was $30{\pm}3mm$ at the watershed line, and it became narrower proximally. The VSW was significantly larger in males than in females (p < 0.001) and in Koreans than in Caucasians (p < 0.001). The effect sizes of the difference for the VSA and VSW between sexes, races and columns were medium to large. Conclusions: Considerable variability exists in the morphometry of the volar distal radius, with sex, race, and column as contributing factors. These results suggest that surgeons should carefully choose an anatomical volar locking plate with appropriate angulation characteristics for each patient to achieve patient-specific alignment of the distal radius.

Ultrasonographic Diagnosis of Extensor Tenosynovitis Caused by Dorsal Screw Prominence after Volar Plate Fixation of Distal Radius Fracture: Case Report (원위 요골 골절의 수장측 금속판 고정술 후 발생한 신전건 활막염에 대한 초음파를 이용한 진단: 증례 보고)

  • Lim, Tae Kang;Kim, Sang Yeol;Kang, Hong Je;Hah, Dae Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.60-64
    • /
    • 2013
  • After volar locking plating of distal radius fracture, complications arising from unrecognized dorsally prominent screws penetrating the extensor compartments are increasingly reported. However, standard radiography and fluoroscopy may not adequately visualize screw lengths, because of complex shape of dorsal cortex of the distal radius. We presented case of ultrasonography diagnosis of extensor tenosynovitis caused by dorsal screw prominence after volar plate fixation of distal radius fracture.

  • PDF

Treatment of Traumatic DislocationofMetacarpophalangeal Joint of the Thumb (무지 중수지 관절의 외상성 탈구 치료)

  • Rhee Seung-Koo;Song Seok-Whan;Lee Hwa-Sung;Chung Jin-Wha;Chung Do-Hyun;Lee Won-Hee
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.2
    • /
    • pp.143-148
    • /
    • 2002
  • Purpose: We examined patients to evaluate the clinical results of traumatic metacarpophalangeal(M-P) dislocations of the thumb, uncommon and irreducible. Materials and Methods: In 11 traumatic M-P dislocations of the thumb, the types of dislocations were 10 dorsal and 1 volar dislocations resulted from the impacted and hyperextended forces on thumb. Authors evaluated the possibility of closed reduction, the anatomical structures interfering with closed reduction, and the surgical approaches. Results: Eight cases were treated with open reduction through volar approach and two cases were treated with closed reduction. Joint fusion was done with a plate in a chronic case. Initial closed reduction was attempted in all cases, but succeeded in only 2 cases because the interposed ruptured volar plate, the flexor pollicis brevis tendon and ulnar sesamoid bone at the volar side of the M-Pjoint were the obstacles to reduce. The metacarpal head was caught in button-hole slit between theflexor pollicis brevis and the ruptured volar joint capsule in all cases. Conclusion: Similar with the M-P joint dislocations of other fingers, the dorsal complex M-P dislocations of the thumb due to hyper extension are unusual and can't easily be reduced by closed manipulation. It is necessary to pay attention to the ruptured volar plate, capsule, the subluxated portion ofthe sesamoid and flexor pollicis brevis as interfering structures.

  • PDF

Delayed Diagnosis of Volar Dislocation of the Distal Ulna after Treatment of the Radial Shaft Fracture (요골 간부 골절 치료 후 지연 발견된 원위 척골의 전방 탈구)

  • Jeon, Suk Ha;Lee, Sanglim
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.427-432
    • /
    • 2021
  • Delayed treatment of volar dislocation of the distal radioulnar joint can result in wrist pain, limited rotation of the forearm, and degenerative arthritis that could be managed only by salvage procedures. A 24-year-old male patient presented with wrist pain and a loss of forearm rotation after surgery for a radial shaft fracture. The shaft of the radius was fixed with a plate and screws with a volar angulation of 7°. The ulnar head was dislocated volar to the distal radius, and the bone defect in the ulnar head was impacted into the volar rim of the sigmoid notch of the radius, preventing the head from being reduced in the joint. Corrective osteotomy of the malunited radial shaft and sliding osteotomy of the proximal ulnar head were performed to fill the distal bone defect. Pain and range of the forearm rotation were improved at postoperative 19 months.

Clinical and Radiological Results of Treating Unstable Distal Radial Fractures with a Domestically Developed Volar Locking Plate That Has the Characteristic of Double-Tiered Subchondral Support (불안정성 원위 요골 골절의 치료에 있어 한국형 이중 연골하지지고정 전방 금속판의 임상적 및 방사선학적 결과)

  • Lee, Chul-Hyung;Jung, Deukhee;An, Chung-Han;Jeong, Uitak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.495-502
    • /
    • 2020
  • Purpose: The aim of this study was to assess the effectiveness of domestically developed volar locking plate which has the concept of double-tiered subchondral support (DSS) in maintaining the reduction after distal radial fracture surgery. Materials and Methods: From July 2017 to December 2018, 54 patients were assessed. Plain radiographs were obtained immediately after surgery and at the last follow-up, and the radiographic parameters were measured in those images: radial length, radial inclination, volar tilt, ulnar variance, and distal dorsal cortical distance. The patients were subdivided into their age, type of fracture, and the position of the plate to evaluate the influence of each factors on the reduction maintenance. Results: Distal dorsal cortical distance in radiographs after the surgery was 5.91 mm (standard deviation, ±1.95 mm) on average. Significant differences in the radial length (p=0.038) and ulnar variance (p=0.001) were observed between immediately after surgery and at the last follow-up. When the parameters were evaluated by dividing the patients into subgroups according to the three specific factors, the ulnar variance showed a significant increase at the last follow-up when the patients were included 65-years-old or older. AO/OTA type C3 fracture, and Soong classification grade 0 plate position (p=0.007, p=0.012, p=0.046, respectively). Conclusion: Using the domestically developed DSS-type volar locking plate, significant reduction after distal radial fracture surgery could be maintained successfully. On the other hand, further study will be needed to determine about the reduction loss of the lunate facet identified in special cases that deal with fractures in elderly patients, unstable AO/OTA type C3 distal radial fractures, and Soong classification grade 0 plate position.

Comparison of Three Surgical Method Outcomes for Dorsal Communition Distal Radial Fractures: External Fixation, External Fixation with Allogenous Bone Graft (DBM) and Volar Locking Plate Fixation (배측 분쇄가 있는 원위부 요골 관절내 골절의 3가지 수술적 치료 결과 비교: 외고정 기구 단독, 외고정 기구와 동종골이식 및 수장측 잠김 압박 금속판)

  • Choi, Joon-Cheol;Na, Hwa-Yeop;Lee, Young-Sang;Kim, Woo-Sung;Oh, Kyung-Soo;Song, Woo-Suk;Kim, Se-Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.115-120
    • /
    • 2009
  • Purpose: To evaluate the outcomes of three different surgical approaches in treating a distal radius fracture with dorsal communition. Materials and Methods: From April, 2006 to May, 2009, 49 patients over age of 60years old with unstable dorsal communition distal radius fracture were analyzed. We compared maintainability of reduction by radiological follow-up observations and clinical outcomes using Mayo wrist scores. One-Way ANOVA test was performed to examine the statistical correlation between the methods. Results: All three approaches provided satisfactory post-op reduction results. However, follow-up observations showed significant loss of reduction in the external fixation only group compared to the added bone graft group and the volar anatomical locking plate group (P<0.05). Mayo wrist score was indifferent between the three groups. Conclusion: Treatment of a distal radius fracture with severe dorsal communition using an external fixation only appears to be insufficient in maintaining reduction of a cancellous bone defect.

  • PDF

Easy and Simple Techniques to Reconstruct Natural Nailfold with the Wrap-around Flap for Finger Reconstruction

  • Takeo Matsusue
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.764-768
    • /
    • 2022
  • The wrap-around flap (WAF) has become a popular approach to thumb reconstruction because the results are functionally and cosmetically excellent. By modifying to a partial toenail transfer, the WAF can also be used for finger reconstruction. However, performing cosmetically superior finger reconstruction is a significant challenge because it is difficult to reconstruct the natural nailfold by partial nail transplantation, although partial nail transplantation is required to reconstruct a narrow fingernail. One side of the reconstructed lateral nailfold tends to be a missing nail margin, and one side of the proximal nailfold angle tends to be retracted. Based on the rationale that loss of the lateral nailfold volume due to the postoperative tension of the volar flap would result in a missing nail margin, the volume of the lateral nailfold was maintained with a single thread that was passed from the nail to the volar flap. Additionally, half of the proximal nailfold from the nail plate was elevated to advance it forward. The results indicated that a cosmetically natural nailfold was achieved with the WAF approach to finger reconstruction. These easy and simple techniques enable reconstruction of a cosmetically natural nailfold using WAF for finger reconstruction.

The Volar Plating of Fracture of the Coronoid Process - Report of Two Cases - (구상돌기 골절에서 내측 접근법을 통한 전방 금속판 고정술 - 2예 보고 -)

  • Jung, Gu-Hee;Cho, Chul-Hyun;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.260-265
    • /
    • 2010
  • Purpose: To report the clinical results of two cases of coronoid process fractures that were treated with volar plating through a medial approach. Materials and Methods: Two fractures of the coronoid process that needed to be fixed were managed with open reduction and internal fixation through a medial approach using 2.4 mm locking compression plates (Compact Hand set$^{(R)}$, Synthes, Switzerland). The patients were followed up for 14 months and 17 months and were evaluated using the Mayo Elbow Performance Score (MEPS). Results: The MEPS was 95 for Case 1 and 100 for Case 2. Active elbow joint motions were $5^{\circ}-120^{\circ}$ (Case 1) and $0^{\circ}-130^{\circ}$ (Case 2). Supination and pronation fully recovered. Conclusion: Satisfactory results can be obtained in cases of coronoid process fractures because volar plating through a medial approach allows sound fixation and early mobilization of the elbow joint.