• Title/Summary/Keyword: Void Size

Search Result 292, Processing Time 0.02 seconds

A Study on the Sound Absorption Properties of Foamed Concrete According to Dilution Ratio of Foaming Agent (기포제 희석비율에 따른 기포콘크리트의 흡음특성에 관한 연구)

  • Kang Ki-Woong;Kang Chul;Kim Ha-Seok;Kwag Eun-Gu;Kwon Ki-Joo;Kim Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.5-8
    • /
    • 2005
  • Sound absorbing performance is affected by porosity and continuity of void, therefore it is important to maintain stabilization of foam and to analyze properties of void pore in hardened state. The purpose of this study is to analyze the sound absorption properties and void characteristic of foamed concrete according to dilution ratio of foaming agent. The results of this experiment were as follows. It is determined that an increase in total and continuous void ratio is achieved by increasing of dilution ratio, and a shorter absorbing time was exhibited at a higher continuous void ratio. When the average void size of foamed concrete was below 1.5mm, the tendency of sound absorption coefficient compared with general sound absorber was appeared similarly.

  • PDF

An Experimental Study on Void Closure Behavior with respect to Reductions in Height (압하율에 따른 기공압착 거동에 관한 실험적 연구)

  • Choi, I.J.;Choi, H.J.;Park, H.J.;Choi, S.;Jung, T.W.;Park, D.K.;Choi, S.K.;Lim, S.J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.114-117
    • /
    • 2009
  • In this work, closing behavior of the voids generated in a casting process was investigated for various parameters such as reductions in height void size and billet rotation during hot open die forging process. The reduction in height and path schedule including the number of paths and billet rotation were chosen as key process variables to express the change of geometrical void shape and void closing behavior. On the other hand, values of die overlapping and die width ratio were set to be constant. Extend of void closure was observed and evaluated using tensile test and microscope. Based on the experimental result, it is ensured that void closure do not occur at 15% and 30% reduction in height as well as one or two rotations of a billet. The useful datum obtained from this study could be utilized to establish an optimum path schedule in the open die forging process.

  • PDF

Analysis of Deformation Localization of Void Material using Nolocal Constitutive Relation (I) (비국소형 구성식을 이용한 보이드 재료의 변형 국소화 거동의 해석(I))

  • 김영석;최홍석;임성언
    • Transactions of Materials Processing
    • /
    • v.9 no.1
    • /
    • pp.59-65
    • /
    • 2000
  • Most studies of failure analysis in ductile metals have been based on the classical plasticity theory using the local constitutive relations. These frequently yields a physically unrealistic solution, in which a numerical prediction of the onset of a deformation localization shows an inherent mesh-size sensitivity. A one way to remedy the spurious mesh sensitivity resulted in the unreasonable results is to incorporate the non-local plasticity into the simulation model, which introduce an internal (material) length-scale parameter into the classical constitutive relations. In this paper, a non-local version of the modified Gurson constitutive relation has been introduced into the finite element formulation of the simulation for plane strain compression of the visco elastic-plastic void material. By introducing the non-local constitutive relations we could successfully removed the inherent mesh-size sensitivity for the prediction of the deformation localization. The effects of non-local constitutive relation are discussed in terms of the load-stroke curve and the strain distributions accross the shear band.

  • PDF

NEAL-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW (과냉 비등유동에 대한 CFD 모의 계산에서의 벽 인접격자 영향)

  • In, W.K.;Shin, C.H.;Chun, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.320-325
    • /
    • 2010
  • A multiphase CFD analysis is performed to investigate the effect of near-wall grid for simulating a subcooled boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and vapor(steam) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit ($y_{w}^{+}$) was examined from 64 to 172 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y_{w}^{+}$ > 100.

  • PDF

NEAR-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW USING WALL BOILING MODEL (벽 비등모델을 이용한 과냉비등 유동에 대한 CFD 모의계산에서 벽 인접격자의 영향)

  • In, W.K.;Shin, C.H.;Chun, T.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.3
    • /
    • pp.24-31
    • /
    • 2010
  • boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and gas(vapour) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit for lqiuid phase ($y^+_{w,l}$) was examined from 101 to 313 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y^+_{w,l}$ > 300 at the tube exit.

A Void Fraction Measurement Technique by Single Camera and Its Application (단일 카메라를 이용한 이상유동 기포율 측정방법의 개발과 응용)

  • Choi, Dong-Whan;Yoo, Jung-Yul;Song, Jin-Ho;Sung, Jae-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.11
    • /
    • pp.904-911
    • /
    • 2007
  • A measurement technique fur void fraction has been proposed using a time-resolved two-phase PIV system and the bubble dynamics has been investigated in gas-liquid two-phase flows. For the three-dimensional evaluation of the bubble information, both the images from the front and side views are simultaneously recorded into a high speed CCD camera by reflecting the side view image on a $45^{\circ}$ oriented mirror to be juxtaposed with the front view image. Then, a stereo-matching technique is applied to calculate the void fraction, bubble size and shape. To obtain the rising bubble velocities, the 2-frame PTV method was adopted. The present technique is applied to freely rising bubby flows in stagnant liquid. The results show that the increase of bubble flow rate gives rise to the increase of bubble size and rising velocity at first. If it goes over a certain level, the rising velocity becomes constant and the horizontal velocity grows bigger instead due to the obstruction of other bubbles.

Material Nonlinear Behavior and Microstructural Transition of Porous Polyurethane Foam under Uniaxial Compressive Loads (일축 압축하중 하 다공성 폴리우레탄폼의 재료비선형 거동 및 미세구조 변화)

  • Lee, Eun Sun;Goh, Tae Sik;Lee, Chi-Seung
    • Korean Journal of Materials Research
    • /
    • v.27 no.12
    • /
    • pp.688-694
    • /
    • 2017
  • Porous materials such as polymeric foam are widely adopted in engineering and biomedical fields. Porous materials often exhibit complex nonlinear behaviors and are sensitive to material and environmental factors including cell size and shape, amount of porosity, and temperature, which are influenced by the type of base materials, reinforcements, method of fabrication, etc. Hence, the material characteristics of porous materials such as compressive stress-strain behavior and void volume fraction according to aforementioned factors should be precisely identified. In this study, unconfined uniaxial compressive test for two types of closed-cell structure polyurethane foam, namely, 0.16 and $0.32g/cm^3$ of densities were carried out. In addition, the void volume fraction of three different domains, namely, center, surface and buckling regions under various compressive strains (10 %, 30 %, 50 % and 70 %) were quantitatively observed using Micro 3D Computed Tomography(micro-CT) scanning system. Based on the experimental results, the relationship between compressive strain and void volume fraction with respect to cell size, density and boundary condition were investigated.

Determining the Optimal Frequency of Ground Penetrating Radar for Detecting Voids in Pavements (도로동공 탐지를 위한 지표투과레이더의 적정 주파수 선정에 관한 연구)

  • Kim, Yeon Tae;Kim, Booil;Kim, Je Won;Park, Hee Mun;Yoon, Jin Sung
    • International Journal of Highway Engineering
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2016
  • PURPOSES : The objective of this study is to determine the optimal frequency of ground penetrating radar (GPR) testing for detecting the voids under the pavement. METHODS : In order to determine the optimal frequency of GPR testing for void detection, a full-scale test section was constructed to simulate the actual size of voids under the pavement. Voids of various sizes were created by inserting styrofoam at varying depths under the pavement. Subsequently, 250-, 500-, and 800-MHz ground-coupled GPR testing was conducted in the test section and the resulting GPR signals were recorded. The change in the amplitude of these signals was evaluated by varying the GPR frequency, void size, and void depth. The optimum frequency was determined from the amplitude of the signals. RESULTS: The capacity of GPR to detect voids under the pavement was evaluated by using three different ground-coupled GPR frequencies. In the case of the B-scan GPR data, a parabolic shape occurred in the vicinity of the voids. The maximum GPR amplitude in the A-scan data was used to quantitatively determine the void-detection capacity. CONCLUSIONS: The 250-MHz GPR testing enabled the detection of 10 out of 12 simulated voids, whereas the 500-MHz testing allowed the detection of only five. Furthermore, the amplitude of GPR detection associated with 250-MHz testing is significantly higher than that of 500-MHz testing. This indicates that 250-MHz GPR testing is well-suited for the detection of voids located at depths ranging from 0.5~2.0 m. Testing at frequencies lower than 250 MHz is recommended for void detection at depths greater than 2 m.

Prediction of the Degree of Saturation Using the Soil-Water Characteristic Curves on an Unsaturated Soil (흙-수분 특성곡선 방정식을 이용한 포화도의 예측)

  • Song, Chang-Seob
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.6
    • /
    • pp.61-69
    • /
    • 2004
  • The aim of the work described in this paper was to confirm the application of the equation of the soil-water characteristic curves on an unsaturated soil. A series of suction test for unsaturated soils was conducted on the selected 4 kinds of soil using modified pressure extractor apparatus. And it was carried out to analyse The experimental parameters which can be describe the soil-water characteristics, were determined by using the data obtained from the experiment. From the results, it was found that The matric suction varied according to the grain size distribution, amount of fine grain particles and void ratio. Also it was found that the residual degree of saturation was decreased with in crease of the void ratio, but the pore size distribution index and air entry value were increased with in crease of the void ratio. And The application of the soil-water characteristic curve equation was confirmed for the various conditions and the various state by the comparison between the measured degree of saturation and the predicted degree of saturation.

Study on the Properties of Porous Concrete According to the Aggregate Shape and Size (골재 입형 및 크기에 따른 포러스 콘크리트의 특성에 관한 연구)

  • Lim, Seo-Hyung;Kang, Hyun-Sik;Jee, Nam-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.93-100
    • /
    • 2005
  • The purpose of this study is to investigate the physical properties of porous concrete according to the aggregate shape and size which is produced by con crusher and impact crusher. For this purpose, the selected test variables were the aggregate size and shape, the ratio of water to cement and the ratio of paste to aggregate. The results of this study showed that its economic performance and physical properties were improved using the aggregate made by impact crusher. The coefficient of permeability and compressive strength of porous concrete had a close correlationship with the void ratio, and it was suggested as a function of void ratio.