• Title/Summary/Keyword: Void Problem

Search Result 83, Processing Time 0.022 seconds

Feature Selection Based on Class Separation in Handwritten Numeral Recognition Using Neural Network (신경망을 이용한 필기 숫자 인식에서 부류 분별에 기반한 특징 선택)

  • Lee, Jin-Seon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.2
    • /
    • pp.543-551
    • /
    • 1999
  • The primary purposes in this paper are to analyze the class separation of features in handwritten numeral recognition and to make use of the results in feature selection. Using the Parzen window technique, we compute the class distributions and define the class separation to be the overlapping distance of two class distributions. The dimension of a feature vector is reduced by removing the void or redundant feature cells based on the class separation information. The experiments have been performed on the CENPARMI handwritten numeral database, and partial classification and full classification have been tested. The results show that the class separation is very effective for the feature selection in the 10-class handwritten numeral recognition problem since we could reduce the dimension of the original 256-dimensional feature vector by 22%.

  • PDF

Forced vibration of a functionally graded porous beam resting on viscoelastic foundation

  • Alnujaie, Ali;Akbas, Seref D.;Eltaher, Mohamed A.;Assie, Amr
    • Geomechanics and Engineering
    • /
    • v.24 no.1
    • /
    • pp.91-103
    • /
    • 2021
  • This paper concerns with forced dynamic response of thick functionally graded (FG) beam resting on viscoelastic foundation including porosity impacts. The dynamic point load is proposed to be triangle point loads in time domain. In current analysis the beam is assumed to be thick, therefore, the two-dimensional plane stress constitutive equation is proposed to govern the stress-strain relationship through the thickness. The porosity and void included in constituent is described by three different distribution models through the beam thickness. The governing equations are obtained by using Lagrange's equations and solved by finite element method. In frame of finite element analysis, twelve-node 2D plane element is exploited to discretize the space domain of beam. In the solution of the dynamic problem, Newmark average acceleration method is used. In the numerical results, effects of porosity coefficient, porosity distribution and foundation parameters on the dynamic responses of functionally graded viscoelastic beam are presented and discussed. The current model is efficient in many applications used porous FGM, such as aerospace, nuclear, power plane sheller, and marine structures.

Goal-oriented multi-collision source algorithm for discrete ordinates transport calculation

  • Wang, Xinyu;Zhang, Bin;Chen, Yixue
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2625-2634
    • /
    • 2022
  • Discretization errors are extremely challenging conundrums of discrete ordinates calculations for radiation transport problems with void regions. In previous work, we have presented a multi-collision source method (MCS) to overcome discretization errors, but the efficiency needs to be improved. This paper proposes a goal-oriented algorithm for the MCS method to adaptively determine the partitioning of the geometry and dynamically change the angular quadrature in remaining iterations. The importance factor based on the adjoint transport calculation obtains the response function to get a problem-dependent, goal-oriented spatial decomposition. The difference in the scalar fluxes from one high-order quadrature set to a lower one provides the error estimation as a driving force behind the dynamic quadrature. The goal-oriented algorithm allows optimizing by using ray-tracing technology or high-order quadrature sets in the first few iterations and arranging the integration order of the remaining iterations from high to low. The algorithm has been implemented in the 3D transport code ARES and was tested on the Kobayashi benchmarks. The numerical results show a reduction in computation time on these problems for the same desired level of accuracy as compared to the standard ARES code, and it has clear advantages over the traditional MCS method in solving radiation transport problems with reflective boundary conditions.

Thermal Resistant Characteristics of Flowable Backfill Materials Using Surplus Soil for Underground Power Utilities (굴착잔토를 재활용한 지중 전력케이블 유동성 뒤채움재의 열저항 특성)

  • Oh, Gidae;Kim, Daehong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.10
    • /
    • pp.15-24
    • /
    • 2010
  • In the case of underground power utilities pipe such as circular pipe, the most difficult problem is low compaction efficiency of the bottom of pipe inducing the failure of utilities. To overcome this problem, various studies have been performed and one of these is CLSM(Controlled Low Strength Materials) accelerated flow ability. But underground power utilities pipe backfill materials is also needed to have good thermal property that can dissipate the heat as rapidly as it is generated. So, in this study, we performed thermal resistancy test for various materials such as sand, weathered soil, clay and mixed soil to analyze the thermal characteristics of CLSM(Controlled Low Strength Materials) with accelerated flow ability for various conditions(water content, unit weight, void ratio, curing time) and to evaluate the applicability for backfill material of underground power utilities pipe. The test results of 16 specimens for thermal resistancy test showed good thermal property that maintained below $85^{\circ}C\;cm/W$.

The Analysis of Flow-Induced Vibration and Design Improvement in KSNP Steam Generators of UCN #5, 6

  • Kim, Sang-Nyung;Cho, Yeon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.74-81
    • /
    • 2004
  • The KSNP Steam Generators (Youngkwang Unit 3 and 4, Ulchin Unit 3 and 4) have a problem of U-tube fretting wear due to Flow Induced Vibration (FIV). In particular, the wear is localized and concentrated in a small area of upper part of U-bend in the Central Cavity region. The region has some conditions susceptible to the FIV, which are high flow velocity, high void fraction, and long unsupported span. Even though the FIV could be occurred by many mechanisms, the main mechanism would be fluid-elastic instability, or turbulent excitation. To remedy the problem, Eggcrate Flow Distribution Plate (EFDP) was installed in the Central Cavity region or Ulchin Unit 5 and 6 steam generators, so that it reduces the flow velocity in the region to a certain level. However, the cause of the FIV and the effectiveness of the EFDP was not thoroughly studied and checked. In this study, therefore the Stability Ratio (SR), which is the ratio of the actual velocity to the critical velocity, was compared between the value before the installation of EFDP and that after. Also the possibility of fluid-elastic instability of KSNP steam generator and the effectiveness of EFDP were checked based on the ATHOS3 code calculation and the Pettigrew's experimental results. The calculated results were plotted in a fluid-elastic instability criteria-diagram (Pettigrew, 1998, Fig. 9). The plotted result showed that KSNP steam generator with EFDP had the margin of Fluid-Elastic Instability by almost 25%.

Energy-efficient Data Dissemination Protocol for Detouring Routing Holes in Wireless Sensor Networks (무선 센서 네트워크에서 라우팅 홀을 우회하기 위한 에너지 효율적 데이타 전달 프로토콜)

  • Ye, Tian;Yu, Fucai;Choi, Young-Hwan;Park, Soo-Chang;Lee, Eui-Sin;Jin, Min-Sook;Kim, Sang-Ha
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.3
    • /
    • pp.321-325
    • /
    • 2008
  • Void areas(holes) as an inevitable phenomenon exist in geographic routing of wireless sensor networks, because the unpredictable and harsh nature application environment or uneven energy consumption. Most of the existing schemes for the issue tend to construct a static detour path to bypass a hole. The static detour path may lead to uneven energy consumption of the nodes on the perimeter of the hole; thus it may enlarge the hole. At the same time, traffic would concentrate on the peripheral node of the hole; thus the nodes on the perimeter of the hole tend to be depleted quietly. In previous work, we have proposed a hole geometric model to reduce the energy consumption and packet collisions of the nodes on the hole boundary. This scheme, however, still has the static detour path problem. Therefore, we extend the previous work by constructing a dynamic detour path hole geometric model for wireless sensor networks in this paper. The location of hole detour anchors is dynamically shifted according to Gaussian function, just generating dynamic hole detour paths.

Improvement of Strain Detection Accuracy of Aircraft FBG Sensors Using Stationary Wavelet Transform (정상 웨이블릿 변환을 이용한 항공기 FBG 센서의 변형률 탐지 정확도 향상)

  • Son, Yeong-Jun;Shin, Hyun-Sung;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.4
    • /
    • pp.273-280
    • /
    • 2019
  • There are many studies that use structure health monitoring to reduce maintenance costs for aircraft and to increase aircraft utilization. Many studies on FBG sensors are also being conducted. However, if the FBG sensor is installed inside the composite, voids will occur between the layers of the composite, resulting in signal split problem. In addition, the FBG sensor is not affected by electromagnetic waves, but will produce electromagnetic noise caused by electronic equipment during post-processing. In this paper, to reduce the error caused by these noises, the stationary wavelet transform, which has the characteristics of movement immutability and is efficient in nonlinear signal analysis, is presented. And in the above situation, we found that noise rejection performance of stationary wavelet transform was better compared with the wavelet packet transform.

An Experimental Study on Mechanical Properties of Ultra-High Strength Powder Concrete (압축강도 300MPa 이상의 초고강도 분체콘크리트 개발을 위한 실험적 연구)

  • Jo, Byung-Wan;Yoon, Kwang-Won;Park, Jung-Hoon;Kim, Heoun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.287-295
    • /
    • 2010
  • In this study, ordinary Portland cement was used and the air void was minimized by using minute quartz as the filler. In addition, steel fibers were used to mitigate the brittle failure problem associated with high strength concrete. This study is in progress to make an Ultra-high strength powdered concrete (UHSPC) which has compressive strength over 300 MPa. To increase the strength of concrete, we have compared and analyzed the compressive strengths of the concretes with different mix proportions and curing conditions by selecting quartz sand, dolomite, bauxite, ferro silicon which have diameters less than 0.6 mm and can increase the bond strength of the transition zone. Ultra-high strength powdered concrete, which is different from conventional concrete, is highly influenced by the materials in the mix. In the study, the highest compressive strength of the powdered concrete was obtained when it is prepared with ferro silicon, followed in order by Bauxite, Dolomite, and Quartz sand. The amount of ferro silicon, when the highest strength was obtained, was 110%, of the weight of the cement. SEM analysis of the UHSPC showed that significant formation of C-S-H and Tobermorite due to high temperature and pressure curing. Production of Ultrahigh strength powdered concrete which has 28-day compressive strength upto 341MPa has been successfully achieved by the following factors; steel fiber reinforcement, fine particled aggregates, and the filling powder to minimize the void space, and the reactive materials.

A Study on Visual-perceptual Centrality in Contemporary Museum Architecture - Focused on Visibility Graph Analysis - (현대 뮤지엄 건축의 시지각적 중심성 분석에 관한 연구 - 가시장분석(Visibility Graph Analysis)을 중심으로 -)

  • Park, Chong-Ku
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.2
    • /
    • pp.166-173
    • /
    • 2014
  • This study analyzed visual-perceptual centrality as a measure to solve the confusion that might occur in visitor's movement in analyzing contemporary museums that have recently expand. Also, this study proposed a new methodology to understand the relationships of the occurrence and convergence of visual-perceptual power. The existing visibility graph analysis mostly ends up in identifying nodes corresponding to the physical environment of museums while the newly proposed visibility graph analysis is a methodology that can analyze the landmark on which the visual-perceptual power occurs and converges, by setting visible space elements as analysis variables, which showed a possibility to draw more reliable results in parallel to the existing analysis, and the results of this analysis are as follows. A public museum located in downtown has a limitation that it cannot but be multi-layered as a way to enlarge for the accommodation of a variety of programs on a limited site. Also, this study found that the problem of visitor orientation occurring in the multi-layer process was solved by a major space which was visual-perceptually void. Also, its types can be summarized into two types: One is setting parameter spaces (ramps, staircases, hallways) linked visual-perceptually to the major space and the other is solving the confusion of the visitor's movement by composing a simple exhibition space. In particular, it is judged that the type solving the confusion of the visitor's movement by composing a simple exhibition space also had a relationship with changes in the characteristics of the exhibited works by period. In addition, it was found that the entrance also appeared in two types: dependent type and independent type in the major space according to the characteristics of the major space.

An Overview of Coal Mine Drainage Treatment (석탄광의 광산배수처리기술 현황 및 전망)

  • 정영욱
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.107-111
    • /
    • 2004
  • This study was undertaken to summarize of the efficiencies of the passive treatment system and suggest future studies for the solution of mine drainage problem. Flow rates of mine drainage from the abandoned coal mines are about 80,000 ton/day. Contaminated mine drainages over about 50 ton/day of flow rate were treated by passive treatment facilities such as Successive Alkalinity Producing Systems(SAPS), oxidation pond and oxic wetland. Chemical analysis for 13 passive coal mine treatment facilities showed that SAPS was the core of treatment facilities because the variation of Fe removal rates was relatively smaller than any other processes and re-leaching of Fe was not measured. The performance and life of SAPS depended on decrease in permeability and retention time due to accumulation of sludge. It is inferred that upgrade of design of the passive treatment system and in-situ treatment using underground void will be necessary for the amelioration of the mine drainage with high metal loading rates.