• 제목/요약/키워드: Void

Search Result 2,156, Processing Time 0.028 seconds

VOID FRACTION PREDICTION FOR SEPARATED FLOWS IN THE NEARLY HORIZONTAL TUBES

  • AHN, TAE-HWAN;YUN, BYONG-JO;JEONG, JAE-JUN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.669-677
    • /
    • 2015
  • A mechanistic model for void fraction prediction with improved interfacial friction factor in nearly horizontal tubes has been proposed in connection with the development of a condensation model package for the passive auxiliary feedwater system of the Korean Advanced Power Reactor Plus. The model is based on two-phase momentum balance equations to cover various types of fluids, flow conditions, and inclination angles of the flow channel in a separated flow. The void fraction is calculated without any discontinuity at flow regime transitions by considering continuous changes of the interfacial geometric characteristics and interfacial friction factors across three typical separated flows, namely stratified-smooth, stratified-wavy, and annular flows. An evaluation of the proposed model against available experimental data covering various types of fluids and flow regimes showed a satisfactory agreement.

Reflection Wave Property of Electromagnetic Radar according to Change of Depth and Thickness of Voids under Concrete Tunnel Lining (콘크리트 터널 라이닝 배면공동의 깊이 및 두께변화에 따른 전자파 레이더의 반사파 특성)

  • Park, Seok-Kyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.789-792
    • /
    • 2004
  • This study aims to detect only voids and estimate the cross-sectional size and thickness of voids using radar. A new method based on radar image processing is carried out with various void sizes and depths. The regression relationship between void size which has different depth and the amplitude characteristics of the radar return is considered in a new method of this research. For the purpose of examining; this regression relationship, experiments with change of void depth, surface area and thickness were carried out. Finally, the threshold value for image processing which aims to represent only voids to be fitted size (width) can be obtained. As the results, a proposed method in this study has a possibility of detecting only voids and estimating void size and thickness with good accuracy.

  • PDF

A Study on the Properties of Porous Concrete according to Volume of Binder and Compaction Energy (결합재량 및 다짐에너지에 따른 포러스콘크리트의 특성에 관한 연구)

  • Lee Jun;Park Seong Bum;Kim Jeong Hwan;Seo Dae Seuk;Kim Bum Kyou;Kim Hyung Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.513-516
    • /
    • 2004
  • The purpose of this study is to investigate properties of porous concrete according to volume of binder and compaction energy. The result of this study, as compaction energy goes on increasing, the actual measured void ratio is decreased according as a change of compaction energy and volume of binder. The compaction energy has a very near value by target void ratio on the whole when it is $50kN{\cdot}m/m^2,\;50\~75kN{\cdot}m/m^2$ in case of target void ratio is $15\%\;and\;25\%$. As compaction energy goes on increasing, compressive strength of specimens picked up when target void ratio is $20\%\;and\;25\%$. Also, compressive strength of specimens bluntly picked up when compaction energy is over $50\~75kN{\cdot}m/m^2$.

  • PDF

Proposal of Matrix Spacing Factor for Analyzing Air Void System in Hardened Concrete (콘크리트 내부공극 분석을 위한 행렬간격계수 모델식의 제안)

  • Jeong Won-Kyong;Jun In-Koo;Kim Yong-Kon;Lee Bong-Hak
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.679-682
    • /
    • 2004
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM is the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the matrix spacing factor by calculation of simplicity. The matrix spacing factor needs two parameters that are air content and numbers of air voids in the hardened concrete. Those are obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The matrix spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

Analysis of Electric Fields Inside GIS with a Small Void in Spacer or with a Metal Impurity (고체 절연체 내부 공극 또는 금속 이물질 존재시의 GIS 내부의 전계 해석)

  • Min, Seok-Won;Kim, Yong-Jun;Kim, Eung-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.6
    • /
    • pp.346-353
    • /
    • 2000
  • In this paper, we developed 3 dimensional Surface Charge Method which could calculate electric fields inside GIS with a small void in solid insulator or with a metal impurity. We find a metal impurity makes much more non-uniform electric field distribution inside GIS than a small void. We also find electric field is much more increased when a metal impurity is close to solid insulator surface at high voltage conductor.

  • PDF

The Effect of Flow Patterns with Polymer Additivies From Two Phase Flow at Vertical up Ward in Circular Tube (원관내 수직상향 2상유동에서 고분자물질이 유동양식에 미치는 영향)

  • 김재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.505-514
    • /
    • 1998
  • Flow pattern of air-water two phase flow depends on the conditions of pressure void fraction and channel geometry. We classify the flow pattern by measuring the output signal of the conductivity probe. under the classified flow pattern we mount a visualization equipment on the test section and take pictures. We vary the concentration of pure solvent and polymer to measure local void fraction. We know that the maximum point position of local void fraction distribution move from the center of the pipe to the wall of the pipe as JSL increase when JSA is constant in two phase flow. But we find that the maximum point position of local void friction move from the wal of the pipe to the center of the pipe when polymer concentration increase.

  • PDF

Fluctuation Characteristics of Radial Void Fraction in Vertical Concentric Annuli (수직동심환상관에서 반경방향 보이드율의 변동특성)

  • Son B.J.;Kim I.S.;Kim M.C.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.5
    • /
    • pp.516-524
    • /
    • 1987
  • This paper presents experimental data of fluctuation characteristics of local void fraction of air-water two-phase flow which are associated with the flow pattern, annular gap size and radial location in vertical concentric annuli with coefficient of skewness and kurtosis. The annular gap widths are 13mm, 11mm, and 9mm for a 38m inner diameter as the lucite outer tube. A electrical conductivity probe was used to measure the local void fraction and traversed diametrically from inner wall to outer wall using radial increments of 2mm. It was shown that distribution of the coefficient of skewness and kurtosis, which is related that the one is the asymmetry and the other peakness of local void fraction distribution was influenced by flow pattern, annular gap size and radial location.

  • PDF

Void Formation Mechanism of Thermoset (열경화성 수지의 기공 생성 원인)

  • 강길호;박상윤
    • Polymer(Korea)
    • /
    • v.28 no.1
    • /
    • pp.35-40
    • /
    • 2004
  • The formation mechanism of void defect which deteriorate composite's property is various according to each composite process. In this paper, void formation and growth mechanism is analyzed by thermal analysis and GC/MS. We made a vacuum chamber for observing pressure effect. Thermal analysis has been done in various condition. Elements of volatiles during resin curing were turned out by GC/MS. The most of volatiles of polyester were composed of styrene (over 80%) and a small quantity of toluene. In case epoxy resin, butyl glycidyl ether was the main element of volatiles (over 90%). We concluded that the original sites of void growth existed in resin and they were eliminated by vacuum and heating process. And the growth of void was influenced by water, diluents, solvent, and reactants in resin.

A Study on the partial Discharge Characteristics according to the Distribution pattern of voids within LDPE (보이드 분포 형태에 따른 LDPE의 부분 방전 특성 연구)

  • Shin, Doo-Seong;Jeon, Seung-Ik;Lee, Jun-Ho;Yun, Do-Hong;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1081-1084
    • /
    • 1995
  • Internal voids located within an insulation will arise partial discharge that causes local breakdown and even the entire insulation breakdown. For HV apparatuses, it is usual case that several voids are formed within non-uniform electric field condition rather than single void within uniform field, which can be solved analitically. The purpose of this work is to study partial discharge and breakdown characteristics of an insulation according to the distribution pattern of two disc-type voids that are located within non-uniform field. The results from numerical field analysis and experiments show that the electric field within the voids decreases as they are arranged more serially, which accordingly results in the increase of partial discharge inception field(PDIF) much higher than that of single void model. With parallel arranged voids, PDIF is almost the same as that of single void model. On the other hand, AC breakdown strength decreases as voids are arranged more serially, which is a natural result considering the reduction of effective insulation thickness. For parallel voids, this effect cannot he noticed where as they show different pattern compared with single void and serial void models in $\Phi$-Q-N analysis. Considering these results may leads us to the conclusion that, in the evaluation of insulating products through PD test, it is not sufficient to determine only PDIV or existence of PD at predetermined voltage level. We could evaluate more accurately by considering all the available data such as PDIV, PD magnitude, PD occurring phase, number of PD pulses, and etc.

  • PDF

The Frequency Distribution of Void Ratio of Granular Materials (입상체시료의 공극비의 빈도분포)

  • Do, Deok-Hyeon;Go, Jae-Man;O, Gyu-Tae
    • Geotechnical Engineering
    • /
    • v.4 no.3
    • /
    • pp.5-18
    • /
    • 1988
  • This study aims at scrutinizing the relationships among the frequency distribution of voids the relative density and the shear strength for the three types of different granular materials. The main results summarized are as follows: (1) The frequency distribution of void ratio of glass beads can be approximated by the negative exponential distribution proposed by Shahinpoor (1981), while as the particle shape changes from spherical to angular the frequency of the denser voids decreases and the distributions are well presented by the beta distribution. (2) For all materials, the standard deviation of void ratio increases with decreasing both the relative density of the material and sphericity of particle. (3) It was found that shear strength of the material was a function of not only the mean void ratio and its standard deviation, but also of the shape of the probability density function of the distribution of void ratio. The more the frequency distribution of void inclines towards the denser voids, the higher the shear strength of the material and vice versa.