• 제목/요약/키워드: Visualization of Water Distribution

검색결과 75건 처리시간 0.025초

X선 영상기법을 이용한 고분자 전해질형 연료전지의 수분분포 가시화 (Visualization of Water Distribution in a Polymer Electrolyte Fuel Cell Using an X-ray Imaging Technique)

  • 임남윤;박구곤;김창수;이상준
    • 한국가시화정보학회지
    • /
    • 제5권2호
    • /
    • pp.33-38
    • /
    • 2007
  • Water management in polymer electrolyte fuel cell (PEFC) has been receiving large attention as an important issue in practical applications. Proper water management is vital to achieve high performance and durability of PEFC. In this study, an X-ray imaging technique was employed to visualize the water distribution in a PEFC quantitatively. X-ray images of the PEFC components with and without water were distinguished clearly. From the visualized X-ray images, we could evaluate the water distribution in the region between separator and gas diffusion layer (GDL) quantitatively. In addition, the contact angle of water in the micro-channels was also clearly visualized.

고분자전해질형 단위 연료전지의 공기극 유로 채널 내 온도 분포와 플러딩 현상에 관한 연구 (A Study of Temperature Distribution and Flooding Phenomena of Cathode now Channel in a PEM Unit Fuel Cell)

  • 김한상;하태훈;민경덕
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.101-104
    • /
    • 2006
  • Water management is considered to be one of the main issues to be addressed for the performance improvement of proton exchange membrane (PEM) fuel cell. For good water management, the detailed information on the water distribution inside an operating PEM fuel cell should be available to main an adequate level of hydration in the PEM While avoiding performance decline due to liquid rater flooding. For the PEM fuel cell to be commercially viable as vehicle applications, the flooding on the cathode side should be minimized during the fuel ceil operation. In this study to investigate cathode flooding and its relation with temperature distribution in flow channels, visualization study was performed on the cathode side of a PEM fuel cell. For the direct visualization of temperature field and water transport in cathode flow channels, a transparent cell was designed and manufactured using quartz window. Water transport and its two-phase flow characteristics in flow channels were investigated experimentally. Also, the visualization of temperature distribution In cathode flow channels was made by using IR camera. Results indicated that the temperature rise near the exit of cathode flow channel was found. It is found that this area corresponds to the flooding area from both temperature and flooding visualization results It is expected that this study can effectively contribute to get the detailed data on water transport linked with heat management during the operation of a PEM fuel cell

  • PDF

X 선 영상기법을 이용한 고분자 전해질형 연료전지의 수분분포 가시화 (Visualization of Water Distribution in a Polymer Electrolyte Fuel Cell Using an X-ray Imaging Technique)

  • 임남윤;박구곤;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.155-158
    • /
    • 2007
  • Water management for Polymer Electrolyte Fuel Cell (PEFC) has been receiving large attention as an important issue in practical applications. Proper water management is vital to achieve high performance and durability of PEFC. In this study, an X-ray imaging technique was employed to visualize the water distribution in a PEFC quantitatively. X-ray images of the PEFC components with and without water are distinguished clearly. From the visualized X-ray images, we could confirm the water distribution in the region between separator and gas diffusion layer (GDL). In addition, the contact angle of water in the micro-channels was also clearly visualized..

  • PDF

PIV를 사용한 2차원 원형 실린더 주위의 유동해석 (Flow Survey around Two-Dimensional Circular Cylinder using PIV Technique)

  • 박건선;곽영기
    • 한국해양공학회지
    • /
    • 제18권3호
    • /
    • pp.1-7
    • /
    • 2004
  • Flaw visualization and velocity field measurement methods have practical applications in the various fluid engineering fields, such as mechanics, ships, and heat fluids. In this study, the basic principles and theoretical methods are used to establish an application technique of Particle Imae Velocimetry(abbreviated to PIV below). Accordingly, the measured results of velocity field distribution of a section inside the Circulating Water Channel (abbreviated to CWC below) are computed using the PIV is presented. The uniformity of velocity distribution of the section in CWC is confirmed, by comparing this PIV data with the existing current meter data. Also, in order to measure the flaw fields of surroundings of 2-dimensional cylinder in the CWC, the flaw visualization technique using the PIV is applied.

Review of Experimental Studies on Swirling Flow in the Circular Tube using PIV Technique

  • Chang, Tae-Hyun;Nah, Do-Baek;Kim, Sang-Woo
    • 한국가시화정보학회지
    • /
    • 제7권1호
    • /
    • pp.21-28
    • /
    • 2009
  • The study of swirling flow is of technical and scientific interest because it has an internal recirculation field, and its tangential velocity is related to the curvature of streamline. The fluid flow for tubes and elbow of heat exchangers has been studied largely through experiments and numerical methods, but studies about swirling flow have been insufficient. Using the particle image velocimetry(PTV) method, this study found the time averaged velocity distribution with swirl and without swirl along longitude sections and the results appear to be physically reasonable. In addition, streamwise mean velocity distribution was compares with that of other. Furthermore, other experimental investigation was performed to study the characteristics of turbulent water flow in a horizontal circular tube by using liquid crystal. 2D PIV technique is employed for velocity measurement and liquid crystal is used for heat transfer experiments in water. Temperature visualization was made quantitatively by calibrating the colour of the liquid crystal versus temperature using various approaches.

중성자 방사선 촬영법을 이용한 PEMFC 내의 2 상 유동 가시화 예비 실험 (Feasibility Test for 2-Phase Flow Visualization at the PEMFC Using the Neutron Radiography Image Technology)

  • 김태주;정용미;김무환;;심철무;이승욱;전진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1658-1663
    • /
    • 2004
  • The feasibility test was performed to check the possibility of 2-phase flow visualization and water distribution at inside the PEMFC using neutron radiography image technique. It was composed using water and pressured air. From the image, several 2-phase flow patterns were discovered and water fraction was estimated by the reference specimen and image analysis.

  • PDF

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.

판형-핀 열교환기 분배면의 유동 가시화 연구 (Flow Visualization Study around the Distributor of Plate-fin Heat Exchangers)

  • 정태식;박승하;김창수;김형범
    • 한국가시화정보학회지
    • /
    • 제10권3호
    • /
    • pp.37-41
    • /
    • 2012
  • Plate-fin heat exchanger is a kind of compact heat exchangers with a good performance in heat transfer. It is widely used in various engineering fields such as aerospace, chemical and biomedical industries. Quantitative and qualitative flow visualization study were performed using the water model of commercial plate-fin heat exchanger with header angles of $30^{\circ}$. The Reynolds number was 100. Conventional digital particle image velocimetry was used to measure the instantaneous velocity fields of the header region and the flow visualization using dye injection and hydrogen bubble method were applied to capture the qualitative flow characteristics. The results showed the existence of separation flow region at the junction area and the bottom wall of the exit region.

중성자 라디오그래피 방법을 이용한 직접 메탄올 연료전지 공기극의 내부 물 분포 가시화 (Visualization of Water Distribution in Cathode Side of a Direct Methanol Fuel Cell Using Neutron Radiography)

  • 제준호;도승우;김태주;김종록;;김무환
    • 대한기계학회논문집B
    • /
    • 제36권10호
    • /
    • pp.965-970
    • /
    • 2012
  • 본 연구에서는 한국원자력연구원 중성자 영상장치와 중성자 영상법을 이용하여 운전 조건에 따른 DMFC 공기극 내부의 물 및 탄소 분포 변화를 가시화하였다. 운전 중에 연료극에서 발생하는 탄산 가스 때문에 정량적인 물량 계측은 힘들지만, 개회로 결과와 비교했을 때, 상대적으로 탄산가스와 물 분포변화를 가시화할 수 있었다. 이는 중성자 영상법은 직접 메탄올 연료전지의 공기극 채널 형상 최적화 및 적절한 물 관리에 유용한 정보를 제공할 수 있으며, 이를 바탕으로 성능 향상에 크게 기여할 것으로 예상된다.

알루미늄 평판관 증발기 헤더 내 공기-물 2상류 분지 실험 (Distribution of Air-Water Two-Phase Flow in a Header of Aluminum Flat Tube Evaporator)

  • 김내현;신태룡;심용섭
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.55-65
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a round header - flat tube geometry simulating a parallel flow heat exchanger. The number of branch flat tube is thirty. The effects of tube outlet direction, tube protrusion depth as well as mass flux, and quality are investigated. The flow at the header inlet is identified as annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted configuration, most of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, however, most of the water flows through rear part of the header. The protrusion depth, mass flux, or quality does not significantly alter the flow pattern. Possible explanations are provided based on the flow visualization results. Negligible difference on the water flow distribution was observed between the parallel and the reverse flow configuration.