• Title/Summary/Keyword: Visual sensitivity

Search Result 384, Processing Time 0.024 seconds

Application of Receiver Operating Characteristics (ROC) Curves for Clinical Diagnostic Tests (임상진단 검사에서 ROC 곡선의 응용)

  • Pak, Son-Il;Koo, Hee-Seung;Hwang, Cheol-Yong;Youn, Hwa-Young
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.312-315
    • /
    • 2002
  • Diagnostic tests often require the determination of cut-off values that discriminate uninfected from infected individuals. The receiver operating characteristic (ROC) curve has been frequently used to attain this purpose and gives a representation of diagnostic accuracy (sensitivity and specificity) of a prediction model when varying the cut-point of a decision rule on a whole spectrum. We have written and tested a visual basic application program in EXCEL for maximum likelihood estimation of a binormal ROC curve, which also computes univariate statistics of a diagnostic test employed. Examples applying for computed tomographic images in radiology and methicillin-resistant Staphylococcus aureus research are given to illustrate this approach. This stand-alone module is available from the first author on request.

A Study on Fashion Design with Geometric Pattern by Linear Type - Focusing on Digital Textile Printing - (선의 형태에 의한 기하학무늬 패션디자인 개발 - 디지털 텍스타일 프린팅 기법을 중심으로-)

  • Oh, Yun-Jeong
    • Journal of Fashion Business
    • /
    • v.13 no.4
    • /
    • pp.178-190
    • /
    • 2009
  • The purpose of this study is to make reference for geometric fashion by investigating geometric patterns by linear types and to propose high value added print and fashion design by designing and producing geometric prints and apparel with them focusing on digital textile printing. As a method of the study, visual and textural data were investigated for theory of geometric pattern and fashion design samples were illustrated. The geometric pattern could be defined as abstract pattern which was crossed with straight line or curve. We could group it into three classes such as straight linear, curved, and mixed type. Images varied with linear types. The image of straight linear type was sharp and modern, that of curved one was soft and feminine and that of mixed one was gorgeous and artistic. And then, 3 geometric prints and 3 one-pieces were designed. The concept of design was simple optimism which was based on sixties. Target was young optimistic women group from the mid teens to the mid twenties who continued to seek after their unique individuality keeping their modern lifestyle. Geometric patterns with straight linear, curved, and mixed type were designed and dresses which went well with them were designed and produced. According to the result of this study, images of geometric fashion can be represented diversely by varying linear type, digital textile printing is good method for high value added geometric fashion because of its high quality and degree of sensitivity, and geometric pattern is a good source for contemporary fashion.

Usefulness of $^{11}C-Methyl-L-and$ D-Methionine PET in Gliomas : with Special Attention to Recurrence

  • Cho, Won-Sang;Kim, Chi-Heon;Kim, Jeong-Eun;Chung, June-Key;Paek, Sun-Ha;Jung, Hee-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.3
    • /
    • pp.176-182
    • /
    • 2006
  • Objective : This study concernes the usefulness of $^{11}C-methyl-L-and$ D-methionine[Met]-positron emission tomography[PET] for glioma grading and detection of recurrence in gliomas, compared with fluorine-18, 2-fluoro-deoxyglucose[FDG]-PET. Methods : Eighty patients underwent Met-PET study for evaluation of glioma : 37 astrocytomas [WHO grade II, 3; III, 8; IV, 26]. 27 oligodendrogliomas [WHO grade II, 16; III, 11]. and 12 suspicious recurrent gliomas. All images were taken within 2 weeks before operation. For suspicious recurrent cases on magnetic resonance images, both FDG-PET and Met-PET were performed. Results : In astrocytoma, Mean maximum standard uptake value[SUV] of region of interest[ROI] was not different between WHO grades [p=0.108]. but ROI/normal contralateral tissue SUV [T/N] ratio was statistically different between WHO grades [p=0.002]. T/N ratio was more closely related to visual scale than maximum SUV of ROI [p<0.001 and p=0.107 respectively]. In oligodendroglioma, there was no statistical difference between WHO grades in view of maximum SUV and T/N ratio. For recurrent gliomas, sensitivity of FDG-PET and Met-PET was 25% and 100%, while specificity of FDG-PET and Met-PET were 100% and 80%, respectively. Conclusion : Met-PET might be an appropriate tool for tumor grading in astrocytoma and be more sensitive for detection of recurrence in gliomas than FDG-PET.

Development of a Novel Multiple Cross-Linking Spiral Amplification for Rapid and Sensitive Detection of HPV16 DNA

  • Zhang, Donghong;Liu, Dongliang;Liu, Bing;Ma, Xiulan
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.4
    • /
    • pp.610-620
    • /
    • 2021
  • There has been increasing interest in the head and neck squamous cell carcinoma (HNSCC) that is caused by high-risk human papillomavirus (HR-HPV) and has posed a significant challenge to Otolaryngologists. A rapid, sensitive, and reliable method is required for the detection of HR-HPV in clinical specimens to prevent and treat HPV-induced diseases. In this study, a multiple cross-linking spiral amplification (MCLSA) assay was developed for the visual detection of HPV-16. In the MCLSA assay, samples were incubated under optimized conditions at 62℃ for 45 min, and after mixing with the SYBR Green I (SGI) dye, the positive amplicons showed bright green fluorescence while the negative amplicons exhibited no obvious change. The specificity test revealed that the developed MCLSA technique had high specificity and could effectively distinguish all five HPV-16 strains from other pathogenic microorganisms. In terms of analytical sensitivity, the limit of detection (LoD) of MCLSA assay was approximately 5.4 × 101 copies/tube, which was 10-fold more sensitive than loop-mediated isothermal amplification (LAMP) and RT-PCR. The detection results of laryngeal cancer specimens collected from 46 patients with suspected HPV infection in the Liaoning region demonstrated that the positive detection rates of MCLSA and hybridized capture 2 kit were 32.61% (15/46). The true positive rate of the MCLSA assay was higher than that of RT-PCR (100% vs. 93.33%) and LAMP (100% vs. 86.67%). Therefore, the MCLSA assay developed in the present study could be a potentially useful tool for the point-of-care (PoC) diagnosis of HR-HPV, especially in resource-limited countries.

Study on the distribution law and influencing factors of pressure field distribution before exploitation in heavy oilfield

  • Zhang, Xing;Jiang, Ting T.;Zhang, Jian H.;Li, Bo;Li, Yu B.;Zhang, Chun Y.;Xu, Bing B.;Qi, Peng
    • Geomechanics and Engineering
    • /
    • v.18 no.2
    • /
    • pp.205-213
    • /
    • 2019
  • A calculation model of reservoir pressure field distribution around multiple production wells in a heavy oil reservoir is established, which can overcome the unreasonable uniform-pressure value calculated by the traditional mathematical model in the multiwell mining areas. A calculating program is developed based on the deduced equations by using Visual Basic computer language. Based on the proposed mathematical model, the effects of drainage rate and formation permeability on the distribution of reservoir pressure are studied. Results show that the reservoir pressure drops most at the wellbore. The farther the distance away from the borehole, the sparser the isobaric lines distribute. Increasing drainage rate results in decreasing reservoir pressure and bottom-hole pressure, especially the latter. The permeability has a significant effect on bottom hole pressure. The study provides a reference basis for studying the dynamic pressure field distribution before thermal recovery technology in heavy oilfield and optimizing construction parameters.

Extracorporeal Shock Wave Therapy with Meridian and Acupoint Theory for Knee Osteoarthritis: Systematic Review (경혈경락이론에 근거한 체외충격파 치료가 무릎 관절염에 미치는 영향: 체계적 문헌 고찰)

  • Kim, Byung-Jun;Lee, Sang-Hyun;Kim, Hyun-Tae;Park, Hye-Jin;Park, Sun-Young;Heo, In;Hwang, Man-Suk;Shin, Byung-Cheul;Hwang, Eui-Hyoung
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.31 no.2
    • /
    • pp.41-48
    • /
    • 2021
  • Objectives To determine the evidence of effectiveness and safety of extracorporeal shock wave therapy (ESWT) with meridian and acupoint theory for knee osteoarthritis. Methods By March 3, 2021, five foreign electronic databases and six Korean medical electronic databases were reviewed with the key words 'extracorporeal shock wave' and '(acupoint OR acupuncture point)'. This key words was set up to increase the sensitivity of the search. After the search, knee osteoarthritis study was selected based on the title and abstract and then included after full-texts were read. Results Five randomized controlled trials were eligible in our inclusion criteria. The meta-analysis of three studies showed positive results for the using ESWT with meridian and acupoint theory for knee osteoarthritis compared with the control group on efficancy rate, visual analog scale and lysholm knee score. but there remains a conundrum regarding the safety of ESWT in the treatment of knee osteoarthritis. Conclusions Most of studies showed ESWT with meridian and acupoint theory were statistically effective to knee osteoarthritis. However there are limitations that the number of selected studies was small, risk of bias was unclear. So use of ESWT with meridian and acupoint theory for knee arthritis has limited evidence compared to usual care.

Odds curve for two classification distributions (두 분류 분포를 위한 오즈 곡선)

  • Hong, Chong Sun;Oh, Se Hyeon;Oh, Tae Gyu
    • The Korean Journal of Applied Statistics
    • /
    • v.34 no.2
    • /
    • pp.225-238
    • /
    • 2021
  • The ROC, TOC, and TROC curves, which are visually descriptive methods of exploring the performance of the binary classification model, are implemented with TP, TN, FP, FN which consist of the confusion matrix, as well as their ratios TPR, TNR, FPR, FNR. In this study, we consider two types odds and then propose an odds curve representing these odds. And show the relationship between the odds curve and ROC curve. Based on the odds curve, we propose not only two statistics that measure the discriminant power of the odds curve but also the criteria for validation ratings of the odds curve. According to the shape of the odds curves, two classification distributions can be estimated and a criterion for validation ratings can be determined. The odds curve can be meaningfully used like other visual methods, and two kinds of measures for the discriminant power can be also applied together as an alternative criterion.

Rapid and Visual Detection of Vibrio parahaemolyticus in Aquatic Foods Using blaCARB-17 Gene-Based Loop-Mediated Isothermal Amplification with Lateral Flow Dipstick (LAMP-LFD)

  • Hu, Yuan-qing;Huang, Xian-hui;Guo, Li-qing;Shen, Zi-chen;LV, Lin-xue;Li, Feng-xia;Zhou, Zan-hu;Zhang, Dan-feng
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.12
    • /
    • pp.1672-1683
    • /
    • 2021
  • Vibrio parahaemolyticus is recognized as one of the most important foodborne pathogens responsible for gastroenteritis in humans. The blaCARB-17 gene is an intrinsic β-lactamase gene and a novel species-specific genetic marker of V. parahaemolyticus. In this study, a loop-mediated isothermal amplification (LAMP) assay combined with a lateral flow dipstick (LFD) was developed targeting this blaCARB-17 gene. The specificity of LAMP-LFD was ascertained by detecting V. parahaemolyticus ATCC 17802 and seven other non-V. parahaemolyticus strains. Finally, the practicability of LAMP-LFD was confirmed by detection with V. parahaemolyticus-contaminated samples and natural food samples. The results showed that the optimized reaction parameters of LAMP are as follows: 2.4 mmol/l Mg2+, 0.96 mmol/l dNTPs, 4.8 U Bst DNA polymerase, and an 8:1 ratio of inner primer to outer primer, at 63℃ for 40 min. The optimized reaction time of the LFD assay is 60 min. Cross-reactivity analysis with the seven non-V. parahaemolyticus strains showed that LAMP-LFD was exclusively specific for V. parahaemolyticus. The detection limit of LAMP-LFD for V. parahaemolyticus genomic DNA was 2.1 × 10-4 ng/μl, corresponding to 630 fg/reaction and displaying a sensitivity that is 100-fold higher than that of conventional PCR. LAMP-LFD in a spiking study revealed a detection limit of approximately 6 CFU/ml, which was similar with conventional PCR. The developed LAMP-LFD specifically identified the 10 V. parahaemolyticus isolates from 30 seafood samples, suggesting that this LAMP-LFD may be a suitable diagnostic method for detecting V. parahaemolyticus in aquatic foods.

Automatic Exposure Control Performance Evaluation of Digital Radiographic Imaging System by Manufacturer Using Coins (동전을 이용한 제조사 별 디지털 방사선 영상 시스템의 자동노출제어 성능 평가)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, we proposed an image quality control for an automatic exposure control (AEC) of digital radiographic imaging system and tried to analyze the performance of the AEC by various manufacturer. The subjects of the experiment were analyzed for the AEC image quality evaluation using digital radiation generators from four manufacturer such as PHILIPS, GE Healthcare, SAMSUNG Healthcare, DK Medical Solution. We used as materials for the implementation of the image quality evaluation by coins (500 won, KOMSCO, Korea). This study evaluated the performance evaluation of the AEC as image quality and exposure dose (Milliampere-seconds; mAs). The image quality evaluation was tried visual assessment by two radiologic technologists and contrast to noise (CNR) by ImageJ. The exposure dose investigated mAs on digital radiation generators. The radiographic coin images acquired 360 images based on change in the control factors of the AEC, which were kVp, the consistency of field configuration and dominant zone, sensitivity and density. As a result, there was a significant difference in the AEC performance between manufacturer. The CNR by the AEC for each manufacturer showed a difference of up to about 1.9 times. The exposed tube current by the AEC for each manufacturer showed a difference of up to about 5.8 times. It is expected that our proposed evaluation method using coins could be applied as the AEC performance evaluation method in the future.

Analysis of the Emotional experience design types of iPhone users - Focused on Q-methodology - (아이폰 사용자의 감성경험디자인 유형 분석 - Q 방법론을 중심으로 -)

  • Lee, Youngju;Lee, Hoeun
    • Journal of Communication Design
    • /
    • v.38
    • /
    • pp.312-320
    • /
    • 2012
  • IPhone users who prefer to study the sensitivity of the subjective aspects of experience design elements, aiming to clarify and subjectivity, Q methodology for the study were able to detect four types through. The first type of usability on the iPhone to pursue the type of individuals who have sufficient understanding of sayongjeok behavior based on the use of features, ease of understanding, the physical sense, usability is important to all who were able to see that consist of: The second types of aesthetics to pursue the type of visual information of the product by the intuitive and subjective aesthetic impression was important to distinguish your type. The third types of discrimination to pursue the type of emotional self-image or self-owned products, to convey a message to anyone seriously here, and the fourth type is the type of active and absolute preference for the iPhone that has been identified as the type of .