• 제목/요약/키워드: Visual DOE4.0 (Visual DOE4.0 simulation)

검색결과 7건 처리시간 0.025초

표준기상데이터(부산지역) 비교 및 분석 (Analysis of Building Energy by the Typical Meteorological Data)

  • 유호천;이관호;강현구
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.13-18
    • /
    • 2009
  • Building is a major energy consumer, and now many efforts are made to save energy in the design and using equipments. The most noticeable achievement in those efforts is a building energy performance assessment program. But most programs are not satisfying enough to provide exact meteorological data, and data source and calculation, and data collection period are not clearly defined. That is common in most of domestic programs. This study collects typical meteorological data in 16 items and analyzes them with Visual DOE 4.0 to compare with existing data. The comparison found that revised data shows a 11% increase on average during cooling period from June to September, and a 13% decrease on average during heating period from December to February, in terms of building heating and cooling load in a monthly basis.

  • PDF

학교건물에서의 외피녹화에 따른 에너지성능 평가에 관한 연구 (A Study on the Evaluation of Energy Performance According to Greenery Cover in Education Buildings)

  • 석호태;양정훈;정재웅
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.40-47
    • /
    • 2008
  • The importance for energy consumptions has being emphasized because of problems of the energy and environment. Especially, education buildings among public buildings which have being emphasized the application of environment-friendly elements because of large energy consumptions. Accordingly, this study established parameters of green walls and green roofs which have ecological effects and energy savings. And then this study analyzed indoor thermal environments and energy consumptions due to green walls and green roofs through the energy simulation(Visual DOE 4.0) and the actual measurement.

표준기상데이터(부산지역) 적용에 따른 건축물에너지 분석 (Analysis of Building Energy by the Typical Meteorological Data)

  • 박소희;유호천
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.202-207
    • /
    • 2008
  • Measures for coping with energy shortage are being sought all over the world. Following such a phenomenon, effort to use less energy in the design of buildings and equipment are being conducted. In particular, a program to evaluate the performance of a building comes into the spotlight. However. indispensable standard wether data to estimate the exact energy consumption of a building is currently unprepared. Thus, after appling standard weather data for four weather factors which were used in previous researches to Visual DOE 4.0, we compared it with the result of the existing data and evaluated them. For the monthly cooling and heating load of our target building, we used revised data for June, July, August, and September during which cooling load is applied. When not the existing data but the revised data was used, the research shows that an average of 14.9% increased in June, August, and September except for July. Also, in a case of heating load, the result by the revised data shows a reduction of an average of 11.9% from October to April during which heating load is applied. In particular, the heating loads of all months for which the revised data was used were more low than those of the existing data. In the maximum cooling and heating load according to load factors, the loads by residents and illumination for which the revised data was used were the same as those of the existing data, but the maximum cooling loads used by the two data have a difference in structures such as walls and roofs. Through the above results, the research cannot clearly grasp which weather data influences the cooling and heating load of a building. However, in the maximum loads by the change of weather data in four factors (dry-bulb temperature, web-bulb temperature, cloud amount, and wind speed) among 14 weather factors, the research shows that 5.95% in cooling load and 27.56% in heating load increased, and these results cannot be ignored. In order to make weather data for Performing energy performance evaluation for future buildings, the flow of weather data for the Present and past should be obviously grasped.

  • PDF

제로에너지 스쿨을 위한 초등 교육시설의 에너지 성능평가 (Energy Performance Evaluation of A Primary School Building for Zero Energy School)

  • 윤종호;신우철;조진일;박재완;김효중;이철성
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.121-126
    • /
    • 2009
  • This study analyzed the standard school's energy usage and patterns as the zero-energy goal of primary school building, and proposed the energy reduction process of school building using energy analysis computing simulation tool. As a analysis simulation tool, Visual DOE 4.0 is used. For analysis of actual energy usage, selected primary school that is standard in the nation's energy consumption. Standard of the school's energy consumption analysis were devided into electric and gas energy. Input parameters of the simulation program based on the literature material and field survey material. after, but it was calibrated to comparison with the standard school's energy consumption. Finally, its energy usage analyzed by component and made the priority order of energy saving. Applied energy saving technologies are envelopment insulation, high efficiency lighting, high performance HAVC system and used active equipment system of solar collector and photovoltaic generation for additional savings.

  • PDF

노후 고등학교 건물의 에너지효율화 리모델링을 위한 요소기술의 성능 평가 (Evaluating Performance of Energy Conservation Measures on Energy-Efficient Remodeling at Deteriorated High School Buildings)

  • 이상춘;최영준;최율
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.97-102
    • /
    • 2013
  • Many countries over the world have acknowledged the global warming problem by greenhouse gas emission and tried to solve the problem. The Korean government has also taken many actions such as The Act on Low Carbon, Green Growth and on Promoting Green Building in that architectural building section takes 1/4 of national greenhouse gas emission. Under the situation that buildings constructed 15 years ago when insulation standards were reinforced take about 74%, The Plan on Vitalizing Green Remodeling, finally established on July 2013, will induce energy-efficient remodeling of deteriorated buildings. Using the energy simulation by the Visual DOE 4.0 program, this paper proposed the ways of energy-efficient remodeling of deteriorated high school buildings by measuring energy saving performance of factors that were drawn from the previous study. The factors considered are insulation, window's SHGC, south louver, system efficiency, and indoor setting temperature. Among them, all factors except SHGC proved contribution to reducing energy use at deteriorated high school buildings, compared with the baseline energy consumption.

공공 건축물의 그린빌딩화를 위한 리노베이션수법의 타당성 연구 (of Renovation for Green Building of Public BuildingA Study on Adequacy)

  • 현군출;김태일;양건
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.1-10
    • /
    • 2010
  • The aims of this study is to analyze that the double-skinned outer surface of building will be the effective measure to improve the use of space and save energy through the evaluation of the buildings renovation. In other words, it is significantly effective to increase the insulation of the outer surface where the most heat loss occurs; it is also energy-saving to convert the space created by pilotis in the southern and northern parts of the buildings into an double-skinned atrium. Research methods of this study are consisted with two steps, situation analysis and simulation analysis. IRISYS 1000 Series Imager was used for research of situation analysis and Visual DOE 4.0 was used for simulation analysis with the 1st Buildings of Jeju Special self-Governing Province. As results of simulation, it was proved that Double skin Method is more effective for green building than basic model. it was predicted to save 8.6% of energy by Double skin Method. Especially, in case of using of ventilation within double-skinned atrium, it was predicted that saving of energy was most effective than other method.

노후 초등학교 건물에너지 절감을 위한 요소기술의 성능 비교 (Comparing Performances of Factors for Reducing Energy at Deteriorated Elementary School Buildings)

  • 이상춘;최영준;김현기;최율
    • KIEAE Journal
    • /
    • 제12권2호
    • /
    • pp.111-116
    • /
    • 2012
  • Faced with the international issue of environmental problems from global warming and energy consumption, the Korean Government has made many efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to reduce energy in the building sector, severe design standards and regulations on saving energy in new buildings have been established. Now, it is necessary to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient, for maximizing energy saving in the building sector. Specially, it is very important to reduce energy through the remodeling process at deteriorated school buildings which were built over 20 years ago and sharply changed into the excessive energy consumption structure from new educational curricula. Thus, this paper examined the effects of potential factors to reduce energy at deteriorated elementary school buildings using the energy simulation on the Visual DOE 4.0 program. Among applied factors of insulations, southern louver, window's SHGC, indoor setup temperature, and system efficiency, all factors except window's SHGC turned out contribute to reduce energy at the deteriorated elementary school buildings, compared with the baseline energy performance.